2015
A novel drug‐coated scoring balloon for the treatment of coronary in‐stent restenosis: Results from the multi‐center randomized controlled PATENT‐C first in human trial
Scheller B, Fontaine T, Mangner N, Hoffmann S, Bonaventura K, Clever Y, Chamie D, Costa R, Gershony G, Kelsch B, Kutschera M, Généreux P, Cremers B, Böhm M, Speck U, Abizaid A. A novel drug‐coated scoring balloon for the treatment of coronary in‐stent restenosis: Results from the multi‐center randomized controlled PATENT‐C first in human trial. Catheterization And Cardiovascular Interventions 2015, 88: 51-59. PMID: 26331782, DOI: 10.1002/ccd.26216.Peer-Reviewed Original ResearchMeSH KeywordsAgedAngioplasty, Balloon, CoronaryBrazilCardiac CathetersCardiovascular AgentsCoated Materials, BiocompatibleCoronary AngiographyCoronary Artery DiseaseCoronary RestenosisFemaleGermanyHumansMaleMetalsMiddle AgedPaclitaxelPercutaneous Coronary InterventionRetreatmentStentsTime FactorsTomography, Optical CoherenceTreatment OutcomeConceptsTarget lesion revascularizationLate lumen lossIn-segment late lumen lossIn-stent restenosisSB groupScoring balloonBare metal stentsAngiographic in-segment late lumen lossCoronary bare metal stentTreatment of in-stent restenosisTreatment of coronary in-stent restenosisRate of binary restenosisCoronary in-stent restenosisAdverse cardiovascular eventsPresence of diabetesFollow-up quantitative coronary angiographyQuantitative coronary angiographyBlinded core labRandomized Controlled TrialsPrimary endpointSecondary endpointsCoronary angiographyMACE rateCardiovascular eventsLesion revascularization
2007
Nonrandomized Comparison of Coronary Stenting Under Intravascular Ultrasound Guidance of Direct Stenting Without Predilation Versus Conventional Predilation With a Semi-Compliant Balloon Versus Predilation With a New Scoring Balloon
de Ribamar Costa J, Mintz GS, Carlier SG, Mehran R, Teirstein P, Sano K, Liu X, Lui J, Na Y, Castellanos C, Biro S, Dani L, Rinker J, Moussa I, Dangas G, Lansky AJ, Kreps EM, Collins M, Stone GW, Moses JW, Leon MB. Nonrandomized Comparison of Coronary Stenting Under Intravascular Ultrasound Guidance of Direct Stenting Without Predilation Versus Conventional Predilation With a Semi-Compliant Balloon Versus Predilation With a New Scoring Balloon. The American Journal Of Cardiology 2007, 100: 812-817. PMID: 17719325, DOI: 10.1016/j.amjcard.2007.03.100.Peer-Reviewed Original ResearchConceptsIntravascular ultrasound guidanceMinimum stent areaStent expansionDirect stentingStent areaUltrasound guidanceStent diameterConsecutive de novo lesionsFinal minimum stent areaDrug-eluting stent eraDe novo lesionsReference vessel sizeSemi-compliant balloonMinimum stent diameterNovo lesionsCoronary stentingStent eraNonrandomized studyNonrandomized comparisonLesion preparationFinal stent expansionScoring balloonPredilationLesion morphologyDES expansion
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply