2024
DIANA - Detectability Investgations using Artificial Nodal Additions
Bayerlein R, Xia M, Xie H, Spencer B, Ouyang J, Fakhri G, Nardo L, Liu C, Badawi R. DIANA - Detectability Investgations using Artificial Nodal Additions. 2024, 00: 1-1. DOI: 10.1109/nss/mic/rtsd57108.2024.10657528.Peer-Reviewed Original ResearchContrast recovery coefficientContrast-to-noise ratioLesion-to-background ratioList-mode dataTotal-body PET/CT scannerPositron emission tomographyContrast recoveryOSEM algorithmPatient motionPET/CT scannerArtificial lesionsImage quality metricsLesion detectionQuantitative accuracyPositron emission tomography scanRecovery coefficientCount densityImage contrastBody mass indexImage noisePositron emission tomography imaging techniquesFrame lengthImage smoothingActivity concentrationsAccuracy of lesion detection
2019
MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiac 18F-FDG imaging
Petibon Y, Sun T, Han P, Ma C, Fakhri G, Ouyang J. MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiac 18F-FDG imaging. Physics In Medicine And Biology 2019, 64: 195009. PMID: 31394518, PMCID: PMC7007962, DOI: 10.1088/1361-6560/ab39c2.Peer-Reviewed Original ResearchConceptsMR-based motion correctionRespiratory motion correctionMotion correctionImproved spatial resolutionReconstructed activity concentrationCardiac PET dataSpatial resolutionCoincidence eventsMR-basedPET imagingContrast-to-noise ratioCardiac PET imagingRespiratory phasesMC dataImprove image qualityMR acquisitionQuantitative accuracyCardiac PETPET dataActivity concentrationsMyocardium wallF-FDG PETDynamics studiesImage qualityMotion artifacts
2014
MR‐based motion correction for PET imaging using wired active MR microcoils in simultaneous PET‐MR: Phantom study
Huang C, Ackerman J, Petibon Y, Brady T, Fakhri G, Ouyang J. MR‐based motion correction for PET imaging using wired active MR microcoils in simultaneous PET‐MR: Phantom study. Medical Physics 2014, 41: 041910. PMID: 24694141, PMCID: PMC3978416, DOI: 10.1118/1.4868457.Peer-Reviewed Original ResearchConceptsMotion correctionMR-based motion correctionStatic phantom dataPET quantitative accuracyPET-MRPET-MR scannersSimultaneous PET-MRHoffman phantomList-modePositron emission tomography imagingPET reconstructionBrain positron emission tomographyIterative PET reconstructionPhantom dataPhantomQuantitative accuracyIndependent noise realizationsImage contrastNoise realizationsHead motionPET dataPositron emission tomographyStatic referenceBrain PET scansMotion artifacts