2017
A minimum-phase Shinnar-Le Roux spectral-spatial excitation RF pulse for simultaneous water and lipid suppression in 1H-MRSI of body extremities
Han P, Ma C, Deng K, Hu S, Jee K, Ying K, Chen Y, Fakhri G. A minimum-phase Shinnar-Le Roux spectral-spatial excitation RF pulse for simultaneous water and lipid suppression in 1H-MRSI of body extremities. Magnetic Resonance Imaging 2017, 45: 18-25. PMID: 28917812, PMCID: PMC5709164, DOI: 10.1016/j.mri.2017.09.008.Peer-Reviewed Original ResearchFeasibility study of using fall‐off gradients of early and late PET scans for proton range verification
Cho J, Grogg K, Min C, Zhu X, Paganetti H, Lee H, Fakhri G. Feasibility study of using fall‐off gradients of early and late PET scans for proton range verification. Medical Physics 2017, 44: 1734-1746. PMID: 28273345, PMCID: PMC5462437, DOI: 10.1002/mp.12191.Peer-Reviewed Original ResearchConceptsProton range verificationProton rangeMonte Carlo simulationsRange verificationFall-offIn-room positron emission tomographyCarlo simulationsResidual proton rangeDose fall-offPostirradiation delayPositron emission tomography imagingSOBP beamProton beamPositron emission tomographyPositron emission tomography scanPhantom studyIn-roomFunction of depthPhantomProtonOff-setMonteAcquisition timeBeamPositron emission tomography signal
2014
A Recommendation on How to Analyze In-Room PET for In Vivo Proton Range Verification Using a Distal PET Surface Method
Min C, Zhu X, Grogg K, Fakhri G, Winey B, Paganetti H. A Recommendation on How to Analyze In-Room PET for In Vivo Proton Range Verification Using a Distal PET Surface Method. Technology In Cancer Research & Treatment 2014, 14: 320-325. PMID: 25246517, PMCID: PMC4898041, DOI: 10.1177/1533034614547457.Peer-Reviewed Original ResearchConceptsIn vivo range verificationIn-room positron emission tomographyRange verificationBeam passageIn vivo proton range verificationIn-roomIn-room PET scannerPositron emission tomography activityProton beam rangeProton range verificationSingle-field treatmentsProton beam deliveryAverage range differencesBeam rangeBeam deliveryPET scannerRoot-mean-square deviationPositron emission tomographyBeamRange differencesLevel surfaceActive lineActivity levelsLocal variationsTreatment course
2009
Improved MAGIC gel for higher sensitivity and elemental tissue equivalent 3D dosimetry
Zhu X, Reese T, Crowley E, Fakhri G. Improved MAGIC gel for higher sensitivity and elemental tissue equivalent 3D dosimetry. Medical Physics 2009, 37: 183-188. PMID: 20175480, PMCID: PMC2801736, DOI: 10.1118/1.3260844.Peer-Reviewed Original ResearchConceptsMAGIC gelTissue equivalentsGel dosimeterRange verificationNuclear reactionsDosimetry applicationsProton beam therapyPhantom materialTime-activity measurementsDosimetry purposesTransverse relaxation rateRelaxation rateBeam therapyDose-response curveSlopes of dose-response curvesGel formulationMAGICDose responseMelting pointSoft tissueDosimetersPhantomTime-activityProtonGlucose