2024
Experimental Evaluation of DE-SPECT: A Hyperspectral SPECT System for Region-Selective 3-D Gamma-Ray Spectroscopy of Molecular Theragnostics
Jin Y, Zannoni E, Sankar P, Gura D, Wu R, Zhu S, Zhang F, Streicher M, Yang H, He Z, Metzler S, Liu C, Sinusas A, Meng L. Experimental Evaluation of DE-SPECT: A Hyperspectral SPECT System for Region-Selective 3-D Gamma-Ray Spectroscopy of Molecular Theragnostics. 2024, 00: 1-2. DOI: 10.1109/nss/mic/rtsd57108.2024.10657212.Peer-Reviewed Original ResearchCadmium zinc tellurideCadmium zinc telluride detectorsGamma-ray spectroscopyHigh-sensitivity imagingUniform phantomResolution phantomSPECT systemZinc telluridePhantom studyImage qualityPhantomImaging capabilitiesImaging performanceAperture systemFOVMultiple radiotracersHigh-resolutionCollimatorDual-field-of-viewPeripheral vascular diseaseDetectorState-of-the-art technologiesTellurideClinical systemsDesign and development of the DE-SPECT system: a clinical SPECT system for broadband multi-isotope imaging of peripheral vascular disease
Zannoni E, Sankar P, Jin Y, Liu C, Sinusas A, Metzler S, Meng L. Design and development of the DE-SPECT system: a clinical SPECT system for broadband multi-isotope imaging of peripheral vascular disease. Physics In Medicine And Biology 2024, 69: 125016. PMID: 38815617, PMCID: PMC11167601, DOI: 10.1088/1361-6560/ad5266.Peer-Reviewed Original ResearchConceptsCadmium zinc tellurideSPECT systemField of viewExcellent spectroscopic performanceExcellent energy resolutionBroad energy rangeIntrinsic spatial resolutionSpatial resolutionClinical SPECT systemEnergy resolutionPeripheral vascular diseaseEnergy rangeMm FWHMSpectroscopic performanceZinc tellurideWide-FOVCollimatorPreliminary experimental dataPartial ringDetection systemImaging capabilitiesImaging performanceExtremity imagingVascular diseaseScout images
2015
Scatter and crosstalk corrections for 99mTc/123I dual‐radionuclide imaging using a CZT SPECT system with pinhole collimators
Fan P, Hutton BF, Holstensson M, Ljungberg M, Pretorius P, Prasad R, Ma T, Liu Y, Wang S, Thorn SL, Stacy MR, Sinusas AJ, Liu C. Scatter and crosstalk corrections for 99mTc/123I dual‐radionuclide imaging using a CZT SPECT system with pinhole collimators. Medical Physics 2015, 42: 6895-6911. PMID: 26632046, DOI: 10.1118/1.4934830.Peer-Reviewed Original ResearchConceptsDual-radionuclide imagingCrosstalk correction methodTEW methodLine source experimentDefect contrastSource experimentsMonte Carlo simulationsIncomplete charge collectionCadmium zinc telluride detectorsLow-energy tailImaging systemCarlo simulationsPinhole collimatorCardiac SPECT systemEnergy tailDetector effectsEnergy spectrumPoint source measurementsSPECT systemCZT detectorsTriple energy window (TEW) methodScatter modelDedicated cardiac SPECT systemsCorrection methodCrosstalk correction
2014
Monte Carlo Simulations of the GE Discovery Alcyone CZT SPECT System
Ljungberg M, Liu C, Fan P, Pretorius P. Monte Carlo Simulations of the GE Discovery Alcyone CZT SPECT System. 2014, 1-3. DOI: 10.1109/nssmic.2014.7430823.Peer-Reviewed Original Research
2011
Respiratory Gating for A Stationary Dedicated Cardiac SPECT System
Liu C, Chan C, Harris M, Le M, Biondi J, Volokh L, Sinusas A. Respiratory Gating for A Stationary Dedicated Cardiac SPECT System. 2011, 2898-2901. DOI: 10.1109/nssmic.2011.6152514.Peer-Reviewed Original ResearchCardiac SPECT systemDedicated cardiac SPECT systemsRespiratory motion correctionTemporal dataSlow gantry rotationData acquisitionCompressive sensorSPECT systemConventional SPECT systemImage qualityMotion correctionRespiratory gating techniquePhysical phantomRespiratory motionContrast recoveryRespiratory gatingUngated imagesImagesRespiratory triggersSystemGating techniqueMyocardial perfusion SPECTUpper abdomenLower chest