Comparative outcomes of Riata and Fidelis lead management strategies: Results from the NCDR‐ICD Registry
Zeitler EP, Wang Y, Pokorney SD, Curtis J, Prutkin JM. Comparative outcomes of Riata and Fidelis lead management strategies: Results from the NCDR‐ICD Registry. Pacing And Clinical Electrophysiology 2021, 44: 1897-1906. PMID: 34520564, DOI: 10.1111/pace.14361.Peer-Reviewed Original ResearchConceptsPre-discharge complicationsNCDR ICD RegistryExtraction groupGenerator replacementElective generator changeGenerator replacement proceduresLead dwell timeMedtronic Sprint FidelisPeri-procedural riskOdds of deathLong-term outcomesMulti-centre populationElective generator replacementReal-world populationLead management strategiesHospital complicationsHospital mortalityICD RegistryTerm outcomesSprint FidelisAdjusted ratesComparative outcomesExtraction patientsComplicationsICD lead
2014
Procedure timing as a predictor of inhospital adverse outcomes from implantable cardioverter-defibrillator implantation: Insights from the National Cardiovascular Data Registry
Hsu JC, Varosy PD, Parzynski CS, Chaudhry SI, Dewland TA, Curtis JP, Marcus GM. Procedure timing as a predictor of inhospital adverse outcomes from implantable cardioverter-defibrillator implantation: Insights from the National Cardiovascular Data Registry. American Heart Journal 2014, 169: 45-52.e3. PMID: 25497247, DOI: 10.1016/j.ahj.2014.10.006.Peer-Reviewed Original ResearchConceptsHospital stayAdverse eventsICD recipientsWeekends/holidaysInhospital deathGreater oddsNational Cardiovascular Data Registry ICD RegistryFirst-time ICD recipientsImplantable cardioverter defibrillator implantationNational Cardiovascular Data RegistryImplantable cardioverter-defibrillator (ICD) proceduresImplantable cardioverter defibrillator recipientsHierarchical multivariable logistic regressionInhospital adverse outcomesCardioverter-defibrillator implantationProlonged hospital stayMultivariable logistic regressionReal-world populationAfternoon/eveningTotal complicationsMultivariable adjustmentAdverse outcomesHospital characteristicsICD implantsData registry
2012
Low Body Mass Index but Not Obesity Is Associated With In‐Hospital Adverse Events and Mortality Among Implantable Cardioverter‐Defibrillator Recipients: Insights From the National Cardiovascular Data Registry
Hsu JC, Varosy PD, Bao H, Wang Y, Curtis JP, Marcus GM. Low Body Mass Index but Not Obesity Is Associated With In‐Hospital Adverse Events and Mortality Among Implantable Cardioverter‐Defibrillator Recipients: Insights From the National Cardiovascular Data Registry. Journal Of The American Heart Association 2012, 1: e003863. PMID: 23316325, PMCID: PMC3540679, DOI: 10.1161/jaha.112.003863.Peer-Reviewed Original ResearchConceptsBody mass indexNormal weight patientsFirst-time ICD recipientsWeight patientsAdverse eventsICD recipientsHospital deathHospital stayUnderweight patientsICD implantationObese patientsMass indexNational Cardiovascular Data Registry ICD RegistryAssociation of BMINational Cardiovascular Data RegistryLower body mass indexImplantable cardioverter defibrillator recipientsHierarchical multivariable logistic regressionMore periprocedural complicationsHospital adverse eventsMultivariable logistic regressionSudden cardiac deathPatient body habitusReal-world populationHospital complications