2002
Quantitative Simultaneous 99MTc/123I Spect: Design Study and Validation With Monte Carlo Simulations and Physical Acquisitions
Fakhri G, Maksud P, Kijewski M, Zimmerman R, Moore S. Quantitative Simultaneous 99MTc/123I Spect: Design Study and Validation With Monte Carlo Simulations and Physical Acquisitions. IEEE Transactions On Nuclear Science 2002, 49: 2315. DOI: 10.1109/tns.2002.803819.Peer-Reviewed Original ResearchMonte Carlo simulationsBrain phantomCarlo simulationsSimultaneous dual-isotope imagingIterative ordered subsetsDigital brain phantomDual-isotope SPECT studyVariable collimator responseArtificial neural networkPhysical acquisitionEnergy windowNonuniform attenuationCollimator responseDual-isotope imagingPhantom acquisitionsScatter correctionClinical cameraNeural networkMontePhantomIsotope imagingCorrected projectionsSPECT studiesProjector/backprojectorClinical applicationOptimization of Ga‐67 imaging for detection and estimation tasks: Dependence of imaging performance on spectral acquisition parameters
Fakhri G, Moore S, Kijewski M. Optimization of Ga‐67 imaging for detection and estimation tasks: Dependence of imaging performance on spectral acquisition parameters. Medical Physics 2002, 29: 1859-1866. PMID: 12201433, DOI: 10.1118/1.1493214.Peer-Reviewed Original ResearchConceptsIdeal signal-to-noise ratioEnergy windowSignal-to-noise ratioMonte Carlo programDetection of spheresTorso phantomPhantom acquisitionsSphere of radiusEstimation taskPhantom dataLower-energyGa-67 imagingPhantomAcquisition parametersActivity concentrationsSpectral acquisition parametersGa-67Sphere sizeEnergyPhotopeakTumor imagingOptimal windowTaskClinicMonte
2001
Optimization of Ga-67 Imaging for Detection and Estimation Tasks: Dependence of Imaging Performance on Choice of Energy Windows
Fakhri G, Moore S, Kijewski M. Optimization of Ga-67 Imaging for Detection and Estimation Tasks: Dependence of Imaging Performance on Choice of Energy Windows. 2001, 3: 1355-1357. DOI: 10.1109/nssmic.2001.1008588.Peer-Reviewed Original ResearchEnergy windowSignal-to-noise ratioMonte Carlo programDetection of spheresIdeal signal-to-noise ratioTorso phantomEstimation taskDetection signal-to-noise ratioPhantom acquisitionsSphere of radiusPhantom dataLower-energyPhotopeakImaging performancePhantomGa-67Detection metricsGa-67 imagingSphere sizeOptimal window widthWindow widthEnergyTaskQuantitative tasksOptimal windowAbsolute Quantitation in Simultaneous 99mTc/123I Brain SPECT Using ANN: Design Optimization and Validation
Fakhri G, Maksud P, Moore S, Zimmerman R, Kijewski M. Absolute Quantitation in Simultaneous 99mTc/123I Brain SPECT Using ANN: Design Optimization and Validation. 2001, 3: 1429-1431. DOI: 10.1109/nssmic.2001.1008605.Peer-Reviewed Original ResearchMonte Carlo simulationsBrain phantomSimultaneous dual-isotope imagingDigital brain phantomDual-isotope SPECT studyVariable collimator responseCarlo simulationsNon-uniform attenuationI-123 imagingEnergy windowCollimator responseDual-isotope imagingPhantom acquisitionsOSEM algorithmArtificial neural networkPhysical acquisitionScatter correctionClinical cameraBrain structuresPhantomIsotope imagingMonteSPECT studiesActivity concentrationsTc-99