2021
PET Imaging Estimates of Regional Acetylcholine Concentration Variation in Living Human Brain
Smart K, Naganawa M, Baldassarri SR, Nabulsi N, Ropchan J, Najafzadeh S, Gao H, Navarro A, Barth V, Esterlis I, Cosgrove KP, Huang Y, Carson RE, Hillmer AT. PET Imaging Estimates of Regional Acetylcholine Concentration Variation in Living Human Brain. Cerebral Cortex 2021, 31: 2787-2798. PMID: 33442731, PMCID: PMC8355478, DOI: 10.1093/cercor/bhaa387.Peer-Reviewed Original ResearchConceptsACh concentrationHuman volunteersHigh ACh concentrationsMuscarinic antagonist scopolamineHealthy human volunteersHuman brainCholinergic receptorsNicotine challengeAntagonist scopolaminePreclinical studiesStriatal regionsPET scansEndogenous neurotransmittersNeuropsychiatric diseasesNonhuman primatesWhole-brain imagesDrug occupancyNicotinic ligandsClinical populationsBrainAcetylcholineDistinct functional rolesStriatumVolunteersFunctional role
2020
Reduced synaptic vesicle protein 2A binding in temporal lobe epilepsy: A [11C]UCB‐J positron emission tomography study
Finnema SJ, Toyonaga T, Detyniecki K, Chen M, Dias M, Wang Q, Lin S, Naganawa M, Gallezot J, Lu Y, Nabulsi NB, Huang Y, Spencer DD, Carson RE. Reduced synaptic vesicle protein 2A binding in temporal lobe epilepsy: A [11C]UCB‐J positron emission tomography study. Epilepsia 2020, 61: 2183-2193. PMID: 32944949, DOI: 10.1111/epi.16653.Peer-Reviewed Original ResearchConceptsMedial temporal lobe sclerosisTemporal lobe epilepsyTLE subjectsPositron emission tomographyLobe epilepsyJ BPSynaptic vesicle protein 2APartial volume correctionTemporal lobe sclerosisPositron emission tomography studyEmission tomography studiesSeizure onset zonePromising biomarker approachJ bindingPresurgical selectionSclerotic hippocampusHippocampal asymmetryTLE patientsRegional binding patternsControl subjectsCentrum semiovaleContralateral regionsEpilepsy patientsOutcome measuresOnset zoneKinetic Modeling and Test–Retest Reproducibility of 11C-EKAP and 11C-FEKAP, Novel Agonist Radiotracers for PET Imaging of the κ-Opioid Receptor in Humans
Naganawa M, Li S, Nabulsi N, Lin SF, Labaree D, Ropchan J, Gao H, Mei M, Henry S, Matuskey D, Carson RE, Huang Y. Kinetic Modeling and Test–Retest Reproducibility of 11C-EKAP and 11C-FEKAP, Novel Agonist Radiotracers for PET Imaging of the κ-Opioid Receptor in Humans. Journal Of Nuclear Medicine 2020, 61: 1636-1642. PMID: 32169917, PMCID: PMC9364890, DOI: 10.2967/jnumed.119.227694.Peer-Reviewed Original Research
2019
PET Imaging of Pancreatic Dopamine D2 and D3 Receptor Density with 11C-(+)-PHNO in Type 1 Diabetes
Bini J, Sanchez-Rangel E, Gallezot JD, Naganawa M, Nabulsi N, Lim K, Najafzadeh S, Shirali A, Ropchan J, Matuskey D, Huang Y, Herold K, Harris PE, Sherwin RS, Carson RE, Cline GW. PET Imaging of Pancreatic Dopamine D2 and D3 Receptor Density with 11C-(+)-PHNO in Type 1 Diabetes. Journal Of Nuclear Medicine 2019, 61: 570-576. PMID: 31601695, PMCID: PMC7198375, DOI: 10.2967/jnumed.119.234013.Peer-Reviewed Original ResearchConceptsT1DM individualsHealthy controlsDopamine DOutcome measuresAcute C-peptide responseSUVR-1Type 1 diabetes mellitusPET/CT scanningDuration of diabetesMaximal glycemic potentiationC-peptide responseClinical outcome measuresInsulin secretory capacityRoutine clinical measuresD3 receptor densityΒ-cell functionC-peptide releaseQuantitative PET measuresΒ-cell massDynamic PET scansQuantitative outcome measuresAgonist PET radioligandDiabetes mellitusReceptor agonistInsulin antibodies
2018
Evaluation of Pancreatic VMAT2 Binding with Active and Inactive Enantiomers of [18F]FP-DTBZ in Healthy Subjects and Patients with Type 1 Diabetes
Naganawa M, Lim K, Nabulsi NB, Lin SF, Labaree D, Ropchan J, Herold KC, Huang Y, Harris P, Ichise M, Cline GW, Carson RE. Evaluation of Pancreatic VMAT2 Binding with Active and Inactive Enantiomers of [18F]FP-DTBZ in Healthy Subjects and Patients with Type 1 Diabetes. Molecular Imaging And Biology 2018, 20: 835-845. PMID: 29468404, PMCID: PMC6533199, DOI: 10.1007/s11307-018-1170-6.Peer-Reviewed Original ResearchConceptsVesicular monoamine transporter type 2Non-displaceable uptakeHealthy controlsSUV ratioType 1 diabetes mellitus groupInactive enantiomerDiabetes mellitus groupBeta-cell massFirst human studyGroup differencesPositron emission tomography (PET) radiotracerTransporter type 2Mellitus groupVT valuesSignificant group differencesT1DM patientsRenal cortexHealthy subjectsPurposePrevious studiesHuman studiesUptake valueType 2Separate daysDistribution volumeReference SUVDose-Related Target Occupancy and Effects on Circuitry, Behavior, and Neuroplasticity of the Glycine Transporter-1 Inhibitor PF-03463275 in Healthy and Schizophrenia Subjects
D’Souza D, Carson RE, Driesen N, Johannesen J, Ranganathan M, Krystal JH, Ahn K, Bielen K, Carbuto M, Deaso E, D’Souza D, Ranganathan M, Naganawa M, Ranganathan M, D’Souza D, Nabulsi N, Zheng M, Lin S, Huang Y, Carson R, Driesen N, Ahn K, Morgan P, Suckow R, He G, McCarthy G, Krystal J, Johannesen J, Kenney J, Gelernter J, Gueorguieva R, Pittman B. Dose-Related Target Occupancy and Effects on Circuitry, Behavior, and Neuroplasticity of the Glycine Transporter-1 Inhibitor PF-03463275 in Healthy and Schizophrenia Subjects. Biological Psychiatry 2018, 84: 413-421. PMID: 29499855, PMCID: PMC6068006, DOI: 10.1016/j.biopsych.2017.12.019.Peer-Reviewed Original ResearchMeSH KeywordsAdultAzabicyclo CompoundsBrainCognitive DysfunctionDose-Response Relationship, DrugDouble-Blind MethodFemaleGlycine Plasma Membrane Transport ProteinsHumansImidazolesKetamineLong-Term PotentiationMagnetic Resonance ImagingMaleMemory, Short-TermMiddle AgedPositron-Emission TomographySchizophreniaYoung AdultConceptsHealthy control subjectsLong-term potentiationSchizophrenia patientsControl subjectsCognitive impairmentClinical trialsGlyT1 occupancyN-methyl-D-aspartate receptor functionGlycine transporter-1 inhibitorKetamine-induced disruptionKetamine-induced effectsFunctional magnetic resonance imagingMagnetic resonance imagingPositron emission tomographyMemory-related activationF-MKSubstudy 1Schizophrenia subjectsResonance imagingReceptor functionCortical regionsEmission tomographyTarget engagementPotentiationSchizophrenia
2016
Event-by-Event Continuous Respiratory Motion Correction for Dynamic PET Imaging
Yu Y, Chan C, Ma T, Liu Y, Gallezot JD, Naganawa M, Kelada OJ, Germino M, Sinusas AJ, Carson RE, Liu C. Event-by-Event Continuous Respiratory Motion Correction for Dynamic PET Imaging. Journal Of Nuclear Medicine 2016, 57: 1084-1090. PMID: 26912437, DOI: 10.2967/jnumed.115.167676.Peer-Reviewed Original Research
2015
Receptor Occupancy of the κ-Opioid Antagonist LY2456302 Measured with Positron Emission Tomography and the Novel Radiotracer 11C-LY2795050
Naganawa M, Dickinson GL, Zheng MQ, Henry S, Vandenhende F, Witcher J, Bell R, Nabulsi N, Lin SF, Ropchan J, Neumeister A, Ranganathan M, Tauscher J, Huang Y, Carson RE. Receptor Occupancy of the κ-Opioid Antagonist LY2456302 Measured with Positron Emission Tomography and the Novel Radiotracer 11C-LY2795050. Journal Of Pharmacology And Experimental Therapeutics 2015, 356: 260-266. PMID: 26628406, PMCID: PMC4727157, DOI: 10.1124/jpet.115.229278.Peer-Reviewed Original ResearchConceptsHours postdosePositron emission tomographyReceptor occupancyEmission tomographySerious adverse eventsSingle oral dosesImportant therapeutic roleΚ-opioid receptorsSubstance abuse disordersFurther clinical testingHealthy human subjectsMultilinear analysis-1 (MA1) methodAntagonist radiotracersAdverse eventsOral dosesBrain penetrationTherapeutic rolePlasma concentrationsAbuse disordersEthanol consumptionLY2456302Clinical testingNovel radiotracersAlcohol dependenceDistribution volumeTest–Retest Reproducibility of Binding Parameters in Humans with 11C-LY2795050, an Antagonist PET Radiotracer for the κ Opioid Receptor
Naganawa M, Zheng MQ, Henry S, Nabulsi N, Lin SF, Ropchan J, Labaree D, Najafzadeh S, Kapinos M, Tauscher J, Neumeister A, Carson RE, Huang Y. Test–Retest Reproducibility of Binding Parameters in Humans with 11C-LY2795050, an Antagonist PET Radiotracer for the κ Opioid Receptor. Journal Of Nuclear Medicine 2015, 56: 243-248. PMID: 25593119, PMCID: PMC4322754, DOI: 10.2967/jnumed.114.147975.Peer-Reviewed Original ResearchConceptsTest-retest variabilityOpioid receptorsOutcome measuresAbsolute test-retest variabilityMultilinear analysis 1Healthy human subjectsSuitable reference regionTest-retest reproducibilityIntraclass correlation coefficientAntagonist radiotracersHealthy subjectsLY2795050PET scansBrain regionsDistribution volumePET radioligandTest-retest performancePET studiesArterial input functionPET radiotracersHuman subjectsReference regionReceptorsVT valuesKOR
2013
Tracer Kinetic Modeling of [11C]AFM, a New PET Imaging Agent for the Serotonin Transporter
Naganawa M, Nabulsi N, Planeta B, Gallezot JD, Lin SF, Najafzadeh S, Williams W, Ropchan J, Labaree D, Neumeister A, Huang Y, Carson RE. Tracer Kinetic Modeling of [11C]AFM, a New PET Imaging Agent for the Serotonin Transporter. Cerebrovascular And Brain Metabolism Reviews 2013, 33: 1886-1896. PMID: 23921898, PMCID: PMC3851894, DOI: 10.1038/jcbfm.2013.134.Peer-Reviewed Original ResearchConceptsPositron emission tomographySerotonin transporterReference tissue modelArterial input functionOne-tissue modelMultilinear reference tissue modelNew PET imaging agentTwo-tissue modelPET imaging agentHealthy human brainSuitable PET radioligandNew positron emission tomographySERT densityRegional time-activity curvesTime-activity curvesEmission tomography dataRegional bindingEmission tomographyPET radioligandRoutine useInterest analysisNoninvasive methodPositron emission tomography dataImaging agentHuman brain
2009
A new graphic plot analysis for determination of neuroreceptor binding in positron emission tomography studies
Ito H, Yokoi T, Ikoma Y, Shidahara M, Seki C, Naganawa M, Takahashi H, Takano H, Kimura Y, Ichise M, Suhara T. A new graphic plot analysis for determination of neuroreceptor binding in positron emission tomography studies. NeuroImage 2009, 49: 578-586. PMID: 19631754, DOI: 10.1016/j.neuroimage.2009.07.021.Peer-Reviewed Original Research