2021
Imaging Pituitary Vasopressin 1B Receptor in Humans with the PET Radiotracer 11C-TASP699
Naganawa M, Nabulsi NB, Matuskey D, Henry S, Ropchan J, Lin SF, Gao H, Pracitto R, Labaree D, Zhang MR, Suhara T, Nishino I, Sabia H, Ozaki S, Huang Y, Carson RE. Imaging Pituitary Vasopressin 1B Receptor in Humans with the PET Radiotracer 11C-TASP699. Journal Of Nuclear Medicine 2021, 63: 609-614. PMID: 34385336, DOI: 10.2967/jnumed.121.262430.Peer-Reviewed Original ResearchMeSH KeywordsHumansHypothalamo-Hypophyseal SystemPituitary-Adrenal SystemPositron-Emission TomographyPyridinesPyrimidinonesReceptors, VasopressinReproducibility of ResultsConceptsMultilinear analysis 1Test-retest variabilityPlasma concentrationsHealthy subjectsR occupancyR antagonistBrain regionsMetabolite-corrected arterial input functionAbsolute test-retest variabilityAdrenal axis activityNovel PET radiotracersSubstantial specific bindingDose-dependent fashionVasopressin 1b receptorTest-retest reproducibilityHalf maximal inhibitory concentrationAdverse eventsAxis activityOutcome measuresReceptor occupancyTime-activity curvesArginine vasopressinPosterior pituitaryDistribution volumeNeuropsychiatric disordersAssessment of test-retest reproducibility of [18F]SynVesT-1, a novel radiotracer for PET imaging of synaptic vesicle glycoprotein 2A
Li S, Naganawa M, Pracitto R, Najafzadeh S, Holden D, Henry S, Matuskey D, Emery PR, Cai Z, Ropchan J, Nabulsi N, Carson RE, Huang Y. Assessment of test-retest reproducibility of [18F]SynVesT-1, a novel radiotracer for PET imaging of synaptic vesicle glycoprotein 2A. European Journal Of Nuclear Medicine And Molecular Imaging 2021, 48: 1327-1338. PMID: 33416954, DOI: 10.1007/s00259-020-05149-3.Peer-Reviewed Original ResearchMeSH KeywordsAnimalsBrainFluorine RadioisotopesGlycoproteinsPositron-Emission TomographyPyridinesPyrrolidinonesRadiopharmaceuticalsReproducibility of ResultsSynaptic VesiclesConceptsTest-retest reproducibilityTime-activity curvesBPND valuesNonhuman primatesAbsolute test-retest variabilitySynaptic vesicle glycoprotein 2AHigh brain uptakeNon-displaceable binding potentialExcellent test-retest reproducibilityGray matter areasHealthy human subjectsHigh uptakeTest-retest variabilityDynamic PET scanningTest-retest reliabilityBrain uptakeDistribution volume valuesCentrum semiovaleUrinary bladderOne-tissue compartment modelMaximum SUVPET scanningPET scansTracer uptakeBrain disorders
2020
Kinetic Modeling and Test–Retest Reproducibility of 11C-EKAP and 11C-FEKAP, Novel Agonist Radiotracers for PET Imaging of the κ-Opioid Receptor in Humans
Naganawa M, Li S, Nabulsi N, Lin SF, Labaree D, Ropchan J, Gao H, Mei M, Henry S, Matuskey D, Carson RE, Huang Y. Kinetic Modeling and Test–Retest Reproducibility of 11C-EKAP and 11C-FEKAP, Novel Agonist Radiotracers for PET Imaging of the κ-Opioid Receptor in Humans. Journal Of Nuclear Medicine 2020, 61: 1636-1642. PMID: 32169917, PMCID: PMC9364890, DOI: 10.2967/jnumed.119.227694.Peer-Reviewed Original Research
2016
Preclinical Evaluation of 18F-PF-05270430, a Novel PET Radioligand for the Phosphodiesterase 2A Enzyme
Chen L, Nabulsi N, Naganawa M, Zasadny K, Skaddan MB, Zhang L, Najafzadeh S, Lin SF, Helal CJ, Boyden TL, Chang C, Ropchan J, Carson RE, Villalobos A, Huang Y. Preclinical Evaluation of 18F-PF-05270430, a Novel PET Radioligand for the Phosphodiesterase 2A Enzyme. Journal Of Nuclear Medicine 2016, 57: 1448-1453. PMID: 27199356, PMCID: PMC5093921, DOI: 10.2967/jnumed.115.171454.Peer-Reviewed Original ResearchAnimalsAzabicyclo CompoundsAzetidinesBrainCyclic Nucleotide Phosphodiesterases, Type 2Macaca mulattaMaleMetabolic Clearance RateMolecular ImagingOrgan SpecificityPositron-Emission TomographyRadiopharmaceuticalsRatsRats, Sprague-DawleyReproducibility of ResultsSensitivity and SpecificitySpecies SpecificityTissue DistributionFirst-in-Human Assessment of the Novel PDE2A PET Radiotracer 18F-PF-05270430
Naganawa M, Waterhouse RN, Nabulsi N, Lin SF, Labaree D, Ropchan J, Tarabar S, DeMartinis N, Ogden A, Banerjee A, Huang Y, Carson RE. First-in-Human Assessment of the Novel PDE2A PET Radiotracer 18F-PF-05270430. Journal Of Nuclear Medicine 2016, 57: 1388-1395. PMID: 27103022, PMCID: PMC5093918, DOI: 10.2967/jnumed.115.166850.Peer-Reviewed Original ResearchMeSH KeywordsAnimalsAzabicyclo CompoundsAzetidinesBrainComputer SimulationCyclic Nucleotide Phosphodiesterases, Type 2Feasibility StudiesFemaleHumansIsotope LabelingMacaca mulattaMaleMetabolic Clearance RateModels, BiologicalMolecular ImagingOrgan SpecificityPilot ProjectsPositron-Emission TomographyRadiopharmaceuticalsReproducibility of ResultsSensitivity and SpecificityTissue DistributionConceptsTest-retest variabilityHuman studiesPET ligandWhite matterNeocortical regionsMultilinear analysis 1MSv/MBqHealthy male subjectsDetectable pharmacologic effectsAppropriate tracer kinetic modelsTest-retest protocolAdverse eventsBrain uptakePharmacologic effectsRegional time-activity curvesTarget doseTime-activity curvesTracer uptakeMale subjectsWhole brainBrain regionsEffective doseCritical organsPET radiotracersNonhuman primates
2015
Test–Retest Reproducibility of Binding Parameters in Humans with 11C-LY2795050, an Antagonist PET Radiotracer for the κ Opioid Receptor
Naganawa M, Zheng MQ, Henry S, Nabulsi N, Lin SF, Ropchan J, Labaree D, Najafzadeh S, Kapinos M, Tauscher J, Neumeister A, Carson RE, Huang Y. Test–Retest Reproducibility of Binding Parameters in Humans with 11C-LY2795050, an Antagonist PET Radiotracer for the κ Opioid Receptor. Journal Of Nuclear Medicine 2015, 56: 243-248. PMID: 25593119, PMCID: PMC4322754, DOI: 10.2967/jnumed.114.147975.Peer-Reviewed Original ResearchConceptsTest-retest variabilityOpioid receptorsOutcome measuresAbsolute test-retest variabilityMultilinear analysis 1Healthy human subjectsSuitable reference regionTest-retest reproducibilityIntraclass correlation coefficientAntagonist radiotracersHealthy subjectsLY2795050PET scansBrain regionsDistribution volumePET radioligandTest-retest performancePET studiesArterial input functionPET radiotracersHuman subjectsReference regionReceptorsVT valuesKOR
2014
Evaluation of the agonist PET radioligand [11C]GR103545 to image kappa opioid receptor in humans: Kinetic model selection, test–retest reproducibility and receptor occupancy by the antagonist PF-04455242
Naganawa M, Jacobsen LK, Zheng MQ, Lin SF, Banerjee A, Byon W, Weinzimmer D, Tomasi G, Nabulsi N, Grimwood S, Badura LL, Carson RE, McCarthy TJ, Huang Y. Evaluation of the agonist PET radioligand [11C]GR103545 to image kappa opioid receptor in humans: Kinetic model selection, test–retest reproducibility and receptor occupancy by the antagonist PF-04455242. NeuroImage 2014, 99: 69-79. PMID: 24844744, PMCID: PMC4140089, DOI: 10.1016/j.neuroimage.2014.05.033.Peer-Reviewed Original ResearchConceptsKappa-opioid receptorsTest-retest reproducibilityTest-retest variabilityAbsolute test-retest variabilityPF-04455242Time-activity curvesIntra-class coefficientOpioid receptorsRegional time-activity curvesMetabolite-corrected arterial input functionHuman positron emission tomography studiesPositron emission tomography studySelective KOR antagonistEmission tomography studiesReceptor occupancy studiesSuitable reference regionHalf maximal inhibitory concentrationAgonist tracersRegional VTAgonist PET radioligandOral doseKOR antagonistsMaximal inhibitory concentrationOral administrationPreclinical models
2013
Event‐by‐event respiratory motion correction for PET with 3D internal‐1D external motion correlation
Chan C, Jin X, Fung EK, Naganawa M, Mulnix T, Carson RE, Liu C. Event‐by‐event respiratory motion correction for PET with 3D internal‐1D external motion correlation. Medical Physics 2013, 40: 112507. PMID: 24320466, DOI: 10.1118/1.4826165.Peer-Reviewed Original ResearchMeSH KeywordsCarcinoma, Non-Small-Cell LungFluorine RadioisotopesHealthy VolunteersHumansHypoxiaImage Processing, Computer-AssistedImaging, Three-DimensionalInsulin-Secreting CellsKidneyLung NeoplasmsMisonidazoleMovementPancreasPositron-Emission TomographyRegression AnalysisReproducibility of ResultsRespirationSignal Processing, Computer-AssistedTetrabenazineX-Ray Microtomography
2009
Improvement of likelihood estimation in Logan graphical analysis using maximum a posteriori for neuroreceptor PET imaging
Shidahara M, Seki C, Naganawa M, Sakata M, Ishikawa M, Ito H, Kanno I, Ishiwata K, Kimura Y. Improvement of likelihood estimation in Logan graphical analysis using maximum a posteriori for neuroreceptor PET imaging. Annals Of Nuclear Medicine 2009, 23: 163-171. PMID: 19225940, DOI: 10.1007/s12149-008-0226-0.Peer-Reviewed Original Research
2008
PET kinetic analysis: error consideration of quantitative analysis in dynamic studies
Ikoma Y, Watabe H, Shidahara M, Naganawa M, Kimura Y. PET kinetic analysis: error consideration of quantitative analysis in dynamic studies. Annals Of Nuclear Medicine 2008, 22: 1-11. PMID: 18250982, DOI: 10.1007/s12149-007-0083-2.Peer-Reviewed Reviews, Practice Guidelines, Standards, and Consensus Statements
2007
Robust estimation of the arterial input function for Logan plots using an intersectional searching algorithm and clustering in positron emission tomography for neuroreceptor imaging
Naganawa M, Kimura Y, Yano J, Mishina M, Yanagisawa M, Ishii K, Oda K, Ishiwata K. Robust estimation of the arterial input function for Logan plots using an intersectional searching algorithm and clustering in positron emission tomography for neuroreceptor imaging. NeuroImage 2007, 40: 26-34. PMID: 18187345, DOI: 10.1016/j.neuroimage.2007.11.035.Peer-Reviewed Original ResearchWavelet denoising for voxel-based compartmental analysis of peripheral benzodiazepine receptors with 18F-FEDAA1106
Shidahara M, Ikoma Y, Seki C, Fujimura Y, Naganawa M, Ito H, Suhara T, Kanno I, Kimura Y. Wavelet denoising for voxel-based compartmental analysis of peripheral benzodiazepine receptors with 18F-FEDAA1106. European Journal Of Nuclear Medicine And Molecular Imaging 2007, 35: 416. PMID: 18026949, DOI: 10.1007/s00259-007-0623-y.Peer-Reviewed Original Research
2005
MAP-based kinetic analysis for voxel-by-voxel compartment model estimation: Detailed imaging of the cerebral glucose metabolism using FDG
Kimura Y, Naganawa M, Yamaguchi J, Takabayashi Y, Uchiyama A, Oda K, Ishii K, Ishiwata K. MAP-based kinetic analysis for voxel-by-voxel compartment model estimation: Detailed imaging of the cerebral glucose metabolism using FDG. NeuroImage 2005, 29: 1203-1211. PMID: 16216532, DOI: 10.1016/j.neuroimage.2005.08.046.Peer-Reviewed Original ResearchAlgorithmsBlood GlucoseBrainBrain MappingComputer GraphicsComputer SimulationEnergy MetabolismFluorodeoxyglucose F18HumansImage Processing, Computer-AssistedImaging, Three-DimensionalKineticsLeast-Squares AnalysisNonlinear DynamicsPhantoms, ImagingPositron-Emission TomographyReproducibility of Results