2023
Impact of motion correction on [18F]-MK6240 tau PET imaging
Tiss A, Marin T, Chemli Y, Spangler-Bickell M, Gong K, Lois C, Petibon Y, Landes V, Grogg K, Normandin M, Becker A, Thibault E, Johnson K, Fakhri G, Ouyang J. Impact of motion correction on [18F]-MK6240 tau PET imaging. Physics In Medicine And Biology 2023, 68: 105015. PMID: 37116511, PMCID: PMC10278956, DOI: 10.1088/1361-6560/acd161.Peer-Reviewed Original ResearchConceptsMotion correctionPET quantitationImpact of motion correctionList-mode reconstructionMotion correction methodList-mode dataMotion-corrected imagesEffect of motion correctionVoxel displacementsPhantom experimentsOptical tracking dataLong acquisitionBrain PET scansSlow motionImage qualityPET imagingPositron emission tomographyCorrectionMotionCorrection methodRates of tau accumulationHead motionMotion metricsPhantomPositron
2017
Feasibility study of using fall‐off gradients of early and late PET scans for proton range verification
Cho J, Grogg K, Min C, Zhu X, Paganetti H, Lee H, Fakhri G. Feasibility study of using fall‐off gradients of early and late PET scans for proton range verification. Medical Physics 2017, 44: 1734-1746. PMID: 28273345, PMCID: PMC5462437, DOI: 10.1002/mp.12191.Peer-Reviewed Original ResearchConceptsProton range verificationProton rangeMonte Carlo simulationsRange verificationFall-offIn-room positron emission tomographyCarlo simulationsResidual proton rangeDose fall-offPostirradiation delayPositron emission tomography imagingSOBP beamProton beamPositron emission tomographyPositron emission tomography scanPhantom studyIn-roomFunction of depthPhantomProtonOff-setMonteAcquisition timeBeamPositron emission tomography signal
2015
National Electrical Manufacturers Association and Clinical Evaluation of a Novel Brain PET/CT Scanner
Grogg K, Toole T, Ouyang J, Zhu X, Normandin M, Li Q, Johnson K, Alpert N, Fakhri G. National Electrical Manufacturers Association and Clinical Evaluation of a Novel Brain PET/CT Scanner. Journal Of Nuclear Medicine 2015, 57: 646-652. PMID: 26697961, PMCID: PMC4818715, DOI: 10.2967/jnumed.115.159723.Peer-Reviewed Original ResearchConceptsNoise-equivalent count rateCount rateLoose cutsMaximum noise-equivalent counting rateSpatial resolutionDetector ringSilicon photomultipliersBrain phantomContrast recoveryAttenuation correctionPET/CT systemCrystal blockPET/CT scannerImage qualityRadial offsetNational Electrical Manufacturers AssociationActivity distributionUnique mobility capabilitiesAxial extentTransverse resolutionPhantomAxial resolutionActivity concentrationsHuman scansLayer 1 cmMapping 15O Production Rate for Proton Therapy Verification
Grogg K, Alpert N, Zhu X, Min C, Testa M, Winey B, Normandin M, Shih H, Paganetti H, Bortfeld T, Fakhri G. Mapping 15O Production Rate for Proton Therapy Verification. International Journal Of Radiation Oncology • Biology • Physics 2015, 92: 453-459. PMID: 25817530, PMCID: PMC4431894, DOI: 10.1016/j.ijrobp.2015.01.023.Peer-Reviewed Original ResearchConceptsDecay constantProton treatment planningMonte Carlo predictionsProton therapyPhantom materialTreatment deliveryPhantomThigh activityPositron emission tomographyProduction rateDynamic PET measurementsTreatment planningRabbit thigh muscleClearance rateProtonIsotopesChanges due to therapyRadionuclide speciesOxygen-15ConstantDecayImaging targetsMontePositronEffects of perfusion