2020
Preclinical Validation of a Single-Scan Rest/Stress Imaging Technique for 13N-Ammonia Positron Emission Tomography Cardiac Perfusion Studies
Guehl N, Pelletier-Galarneau M, Wooten D, Guerrero J, Kas A, Normandin M, Fakhri G, Alpert N. Preclinical Validation of a Single-Scan Rest/Stress Imaging Technique for 13N-Ammonia Positron Emission Tomography Cardiac Perfusion Studies. Circulation Cardiovascular Imaging 2020, 13: e009407. PMID: 31959009, PMCID: PMC7205554, DOI: 10.1161/circimaging.119.009407.Peer-Reviewed Original ResearchConceptsMyocardial blood flowPerfusion imagingMyocardial perfusion imaging proceduresSCAN-ALeft anterior descending arteryDose of adenosineAbsolute myocardial blood flowStress perfusion imagingAnterior descending arteryCardiac perfusion studiesMyocardial blood flow measurementsBland-Altman analysisNonstationary kinetic modelPositron emission tomographyMeasurement of restMyocardial blood flow valuesPharmacological stressorDescending arteryPreclinical validationMyocardial blood flow estimatesSingle-scan acquisitionPerfusion studiesVariable dosesImaging sessionMicrosphere MBF measurements
2018
Joint reconstruction of rest/stress myocardial perfusion SPECT
Lai X, Petibon Y, Fakhri G, Ouyang J. Joint reconstruction of rest/stress myocardial perfusion SPECT. Physics In Medicine And Biology 2018, 63: 135019. PMID: 29897044, PMCID: PMC6245543, DOI: 10.1088/1361-6560/aacc2f.Peer-Reviewed Original ResearchConceptsMyocardial perfusion imagingSingle photon emission computed tomographyReversible defectsSignal-to-noise ratioRest/stress SPECT myocardial perfusion imagingSPECT myocardial perfusion imagingConventional subtraction methodDefect detectionJoint methodPhoton emission computed tomographySubtraction methodReverse mappingClinical dose levelsEmission computed tomographyImprove defect detectionLow noiseNon-invasive assessmentClinical dosePerfusion defectsReduced doseImprove radiologists' performanceReconstruction frameworkRest imagesPerfusion imagingDose levels
2016
Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR
Petibon Y, Guehl N, Reese T, Ebrahimi B, Normandin M, Shoup T, Alpert N, Fakhri G, Ouyang J. Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR. Physics In Medicine And Biology 2016, 62: 326-343. PMID: 27997375, PMCID: PMC5241952, DOI: 10.1088/1361-6560/aa5087.Peer-Reviewed Original ResearchConceptsSimultaneous PET-MRPET myocardial perfusion imagingMyocardial perfusion imagingPoint spread functionPoint-spread function correctionUngated dataMotion correctionPET-MRPartial volume effectsApparent wall thicknessMyocardial blood flowPartial volume effect correctionMR-based motion correctionMotion fieldPET-MR scannersPoint spread function modelPET dataPerfusion imagingImage qualityImpact of motionDynamic myocardial perfusion imagingAttenuation mapNon-rigid registrationAbsolute myocardial blood flowUngated images