2023
Targeted therapy with a localised abluminal groove, low-dose sirolimus-eluting, biodegradable-polymer coronary stent - five-year results of the TARGET All Comers randomised clinical trial.
Lansky A, Xu B, Baumbach A, Kelbæk H, van Royen N, Zheng M, Knaapen P, Slagboom T, Johnson T, Vlachojannis G, Arkenbout K, Holmvang L, Janssens L, Brugaletta S, Naber C, Schmitz T, Anderson R, Rittger H, Berti S, Barbato E, Toth G, Maillard L, Valina C, Buszman P, Thiele H, Schächinger V, Wijns W. Targeted therapy with a localised abluminal groove, low-dose sirolimus-eluting, biodegradable-polymer coronary stent - five-year results of the TARGET All Comers randomised clinical trial. EuroIntervention 2023, 19: e844-e855. PMID: 37860860, PMCID: PMC10687649, DOI: 10.4244/eij-d-23-00409.Peer-Reviewed Original ResearchConceptsTarget lesion failureDP-EES groupPercutaneous coronary interventionBP-SES groupBP-SESPrimary endpointDP-EESRate of TLFBiodegradable polymer sirolimus-eluting stentsST-elevation myocardial infarction (STEMI) presentationMyocardial infarction presentationSirolimus-eluting stentsFive-year resultsLong-term safetyAbluminal grooveLesion failureSecondary endpointsComers populationCoronary interventionMyocardial ischaemiaStent implantationClinical trialsTargeted therapyLandmark analysisStudy outcomes
2019
Safety and Effectiveness of Coronary Intravascular Lithotripsy for Treatment of Severely Calcified Coronary Stenoses
Ali ZA, Nef H, Escaned J, Werner N, Banning AP, Hill JM, De Bruyne B, Montorfano M, Lefevre T, Stone GW, Crowley A, Matsumura M, Maehara A, Lansky AJ, Fajadet J, Di Mario C. Safety and Effectiveness of Coronary Intravascular Lithotripsy for Treatment of Severely Calcified Coronary Stenoses. Circulation Cardiovascular Interventions 2019, 12: e008434. PMID: 31553205, DOI: 10.1161/circinterventions.119.008434.Peer-Reviewed Original ResearchMeSH KeywordsAgedAged, 80 and overCardiac CatheterizationCoronary AngiographyCoronary StenosisEuropeFemaleHumansLithotripsyMaleMiddle AgedPatient SafetyPercutaneous Coronary InterventionProspective StudiesRisk FactorsSeverity of Illness IndexStentsTime FactorsTomography, Optical CoherenceTreatment OutcomeUnited StatesVascular CalcificationConceptsSevere coronary artery calcificationCoronary artery calcificationMajor adverse cardiac eventsAdverse cardiac eventsPrimary end pointIntravascular lithotripsyOptical coherence tomographyCardiac eventsStent implantationPlaque fractureHospital major adverse cardiac eventsNon-Q-wave myocardial infarctionOptical coherence tomography substudyIndependent clinical events committeeCoherence tomographyDrug-eluting stent implantationEnd pointCoronary intravascular lithotripsyClinical events committeeHigh procedural successIndependent core laboratoryAcute luminal gainPost-approval studiesMechanism of actionCalcium fracture
2017
Impact of Stent Size Selection on Acute and Long-Term Outcomes After Drug-Eluting Stent Implantation in De Novo Coronary Lesions
Kitahara H, Okada K, Kimura T, Yock PG, Lansky AJ, Popma JJ, Yeung AC, Fitzgerald PJ, Honda Y. Impact of Stent Size Selection on Acute and Long-Term Outcomes After Drug-Eluting Stent Implantation in De Novo Coronary Lesions. Circulation Cardiovascular Interventions 2017, 10: e004795. PMID: 28951394, DOI: 10.1161/circinterventions.116.004795.Peer-Reviewed Original ResearchConceptsDrug-eluting stent implantationReference vessel diameterLong-term outcomesDe novo coronary lesionsNovo coronary lesionsStent implantationDrug-eluting stentsIncomplete stent appositionClinical outcomesCoronary lesionsStent thrombosisStent oversizingStent appositionAngiographic reference vessel diameterSmaller reference vessel diameterGreater stent expansionLesion revascularization rateTarget lesion revascularizationGreater adverse eventsSerial coronary angiographyArterial wall injuryStent size selectionLesion revascularizationRevascularization ratesAdverse events
2013
Impact of advanced age on the safety and effectiveness of paclitaxel‐eluting stent implantation in patients with ST‐segment elevation myocardial infarction undergoing primary angioplasty
Dudek D, Mehran R, Dziewierz A, Witzenbichler B, Brodie BR, Kornowski R, Fahy M, Lansky AJ, Rakowski T, Legutko J, Bryniarski L, Stone GW. Impact of advanced age on the safety and effectiveness of paclitaxel‐eluting stent implantation in patients with ST‐segment elevation myocardial infarction undergoing primary angioplasty. Catheterization And Cardiovascular Interventions 2013, 82: 869-877. PMID: 23359554, DOI: 10.1002/ccd.24813.Peer-Reviewed Original ResearchConceptsPrimary percutaneous coronary interventionST-segment elevation myocardial infarctionPaclitaxel-eluting stent implantationPrimary PCIBare metal stentsElevation myocardial infarctionYears of ageStent implantationOlder patientsMyocardial infarctionLower riskIschemic target vessel revascularizationMajor adverse cardiac eventsHORIZONS-AMI studyHORIZONS-AMI trialReduction of MACEAdverse cardiac eventsTarget vessel revascularizationClinical end pointsPercutaneous coronary interventionLong-term resultsImpact of ageCause deathMajor bleedingPrimary angioplastyPlaque shift and distal embolism in patients with acute myocardial infarction
Wu X, Maehara A, He Y, Xu K, Oviedo C, Witzenbichler B, Lansky AJ, Dressler O, Parise H, Stone GW, Mintz GS. Plaque shift and distal embolism in patients with acute myocardial infarction. Catheterization And Cardiovascular Interventions 2013, 82: 203-209. PMID: 22936619, DOI: 10.1002/ccd.24644.Peer-Reviewed Original ResearchMeSH KeywordsAgedBiomarkersChi-Square DistributionCoronary AngiographyCoronary Artery DiseaseCoronary ThrombosisCoronary VesselsCreatine Kinase, MB FormEmbolismFemaleHumansLinear ModelsMaleMiddle AgedMyocardial InfarctionNo-Reflow PhenomenonPercutaneous Coronary InterventionPlaque, AtheroscleroticPredictive Value of TestsProsthesis DesignRandomized Controlled Trials as TopicRetrospective StudiesStentsTreatment OutcomeUltrasonography, InterventionalConceptsThrombus groupCK-MBAngiographic thrombusPlaque shiftReference segmentsAxial plaque redistributionDistal plaque embolizationDistal reference segmentsHORIZONS-AMI trialNative coronary lesionsM volumeAcute myocardial infarctionVolumetric intravascular ultrasoundBare metal stentsOverall plaque volumePeriprocedural elevationPlaque redistributionDistal embolismCoronary lesionsPlaque embolizationMyocardial infarctionStent implantationPlaque volumeInfarction lesionsIntravascular ultrasound
2011
Predictors and Implications of Stent Thrombosis in Non–ST-Segment Elevation Acute Coronary Syndromes
Palmerini T, Dangas G, Mehran R, Caixeta A, Généreux P, Fahy MP, Xu K, Cristea E, Lansky AJ, Stone GW. Predictors and Implications of Stent Thrombosis in Non–ST-Segment Elevation Acute Coronary Syndromes. Circulation Cardiovascular Interventions 2011, 4: 577-584. PMID: 22028471, DOI: 10.1161/circinterventions.111.963884.Peer-Reviewed Original ResearchMeSH KeywordsAcute Coronary SyndromeAgedAngioplasty, Balloon, CoronaryComorbidityCoronary ThrombosisCoronary VesselsDiabetes Mellitus, Type 1Drug-Eluting StentsElectrocardiographyFemaleFibrinolytic AgentsFollow-Up StudiesHumansMaleMetalsMiddle AgedPredictive Value of TestsPrevalenceProspective StudiesRisk FactorsStentsConceptsSegment elevation acute coronary syndromesElevation acute coronary syndromeProbable stent thrombosisAcute coronary syndromeStent thrombosisNSTE-ACSCardiac mortalityCoronary syndromeIndependent predictorsStent implantationDiseased vesselsUrgent Intervention Triage Strategy (ACUITY) trialDynamic ST segment changesIncidence of STInsulin-treated diabetes mellitusElective stent implantationEarly stent thrombosisPercutaneous coronary interventionST-segment changesBare metal stentsDrug-eluting stentsLate stent thrombosisST-segment deviationAcute CatheterizationAntithrombotic regimensComparison of Direct Stenting With Conventional Stent Implantation in Acute Myocardial Infarction
Möckel M, Vollert J, Lansky AJ, Witzenbichler B, Guagliumi G, Peruga JZ, Brodie BR, Kornowski R, Dudek D, Farkouh ME, Parise H, Mehran R, Stone GW, Investigators H. Comparison of Direct Stenting With Conventional Stent Implantation in Acute Myocardial Infarction. The American Journal Of Cardiology 2011, 108: 1697-1703. PMID: 21906709, DOI: 10.1016/j.amjcard.2011.07.040.Peer-Reviewed Original ResearchConceptsST-segment elevation myocardial infarctionPrimary percutaneous coronary interventionElevation myocardial infarctionPercutaneous coronary interventionDirect stentingMyocardial infarctionCoronary interventionStent implantationConventional stentingPropensity score-based analysisAcute Myocardial Infarction trialDirect stenting groupMyocardial Infarction trialST-segment resolutionTarget lesion revascularizationPresent study cohortAcute myocardial infarctionScore-based analysisConventional stent implantationPropensity-score matchingCause deathHarmonizing OutcomesLesion revascularizationMajor bleedingStenting groupThe Relationship Between Attenuated Plaque Identified by Intravascular Ultrasound and No-Reflow After Stenting in Acute Myocardial Infarction The HORIZONS-AMI (Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction) Trial
Wu X, Mintz GS, Xu K, Lansky AJ, Witzenbichler B, Guagliumi G, Brodie B, Kellett MA, Dressler O, Parise H, Mehran R, Stone GW, Maehara A. The Relationship Between Attenuated Plaque Identified by Intravascular Ultrasound and No-Reflow After Stenting in Acute Myocardial Infarction The HORIZONS-AMI (Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction) Trial. JACC Cardiovascular Interventions 2011, 4: 495-502. PMID: 21596321, DOI: 10.1016/j.jcin.2010.12.012.Peer-Reviewed Original ResearchMeSH KeywordsAngioplasty, Balloon, CoronaryChi-Square DistributionCoronary AngiographyCoronary Artery DiseaseCoronary CirculationEuropeHumansLogistic ModelsMulticenter Studies as TopicMyocardial InfarctionNo-Reflow PhenomenonPlaque, AtheroscleroticPredictive Value of TestsRandomized Controlled Trials as TopicRetrospective StudiesRisk AssessmentRisk FactorsStentsStroke VolumeTreatment OutcomeUltrasonography, InterventionalUnited StatesVentricular Function, LeftConceptsAcute myocardial infarctionAttenuated plaqueHORIZONS-AMI trialPercutaneous coronary interventionMyocardial infarctionAttenuation scoreIntravascular ultrasoundVentricular ejection fractionGrayscale intravascular ultrasoundAngiographic thrombusFinal ThrombolysisCoronary interventionDistal embolizationEjection fractionMechanical obstructionTransient deteriorationCoronary flowStent implantationNo-ReflowPatientsMultivariate analysisLower baselineStent expansionInfarctionPlaques
2010
Mesh covered stent in ST-segment elevation myocardial infarction.
Dudek D, Dziewierz A, Rzeszutko Ł, Legutko J, Dobrowolski W, Rakowski T, Bartus S, Dragan J, Klecha A, Lansky AJ, Siudak Z, Zmudka K. Mesh covered stent in ST-segment elevation myocardial infarction. EuroIntervention 2010, 6: 582-9. PMID: 21044911, DOI: 10.4244/eijv6i5a98.Peer-Reviewed Original ResearchConceptsST-segment elevation myocardial infarctionPercutaneous coronary interventionElevation myocardial infarctionDistal embolisationMyocardial infarctionTotal major adverse cardiac events rateFinal TIMI grade 3 flowMajor adverse cardiac event ratesAdverse cardiac event ratesMyocardial blush grade 3Primary percutaneous coronary interventionTIMI grade 3 flowCardiac event rateGrade 3 flowSingle-arm studySTEMI patientsCoronary interventionThrombus aspirationArm studyStent implantationClinical endpointsGrade 3PatientsClinical feasibilityEvent ratesEVALUATION OF THIENOPYRIDINE COMPLIANCE AND STENT THROMBOSIS RATES AFTER EVEROLIMUS-ELUTING AND PACLITAXEL-ELUTING STENT IMPLANTATION: 3-YEAR RESULTS FROM THE SPIRIT III ANALYSIS
Cox D, Sudhir K, Hermiller J, Applegate R, Gordon P, Doostzadeh J, Jonnavithula L, Koo K, Maloney T, Lansky A, Simonton C, Stone G. EVALUATION OF THIENOPYRIDINE COMPLIANCE AND STENT THROMBOSIS RATES AFTER EVEROLIMUS-ELUTING AND PACLITAXEL-ELUTING STENT IMPLANTATION: 3-YEAR RESULTS FROM THE SPIRIT III ANALYSIS. Journal Of The American College Of Cardiology 2010, 55: a191.e1791. DOI: 10.1016/s0735-1097(10)61792-5.Peer-Reviewed Original ResearchCOMPLIANCE WITH DUAL ANTIPLATELET THERAPY AND SUBSEQUENT ADVERSE EVENTS IN PATIENTS WITH STEMI UNDERGOING STENT IMPLANTATION: ANALYSIS FROM THE HORIZONS-AMI TRIAL
Mehran R, Nikolsky E, Witzenbichler B, Guagliumi G, Peruga J, Brodie B, Dudek D, Kornowski R, Hartmann F, Caixeta A, Haratani N, Dangas G, Lansky A, Stone G. COMPLIANCE WITH DUAL ANTIPLATELET THERAPY AND SUBSEQUENT ADVERSE EVENTS IN PATIENTS WITH STEMI UNDERGOING STENT IMPLANTATION: ANALYSIS FROM THE HORIZONS-AMI TRIAL. Journal Of The American College Of Cardiology 2010, 55: a185.e1728. DOI: 10.1016/s0735-1097(10)61729-9.Peer-Reviewed Original Research
2009
Intravascular Ultrasound Assessment of the Incidence and Predictors of Edge Dissections After Drug-Eluting Stent Implantation
Liu X, Tsujita K, Maehara A, Mintz GS, Weisz G, Dangas GD, Lansky AJ, Kreps EM, Rabbani LE, Collins M, Stone GW, Moses JW, Mehran R, Leon MB. Intravascular Ultrasound Assessment of the Incidence and Predictors of Edge Dissections After Drug-Eluting Stent Implantation. JACC Cardiovascular Interventions 2009, 2: 997-1004. PMID: 19850262, DOI: 10.1016/j.jcin.2009.07.012.Peer-Reviewed Original ResearchConceptsStent edge dissectionEdge dissectionDES implantationPlaque eccentricityIntravascular ultrasoundIntramural hematomaPlaque burdenStent implantationStent edgeDrug-Eluting Stent ImplantationDistal stent edgeStent restenosis lesionsBare-metal stentingIntravascular ultrasound assessmentResidual plaque areaCoronary dissectionRestenosis lesionsAngiographic findingsIndependent predictorsHematoma groupResidual plaqueUltrasound assessmentDissection groupPlaque areaNondissection group5-Year Clinical Outcomes After Sirolimus-Eluting Stent Implantation Insights From a Patient-Level Pooled Analysis of 4 Randomized Trials Comparing Sirolimus-Eluting Stents With Bare-Metal Stents
Caixeta A, Leon MB, Lansky AJ, Nikolsky E, Aoki J, Moses JW, Schofer J, Morice MC, Schampaert E, Kirtane AJ, Popma JJ, Parise H, Fahy M, Mehran R. 5-Year Clinical Outcomes After Sirolimus-Eluting Stent Implantation Insights From a Patient-Level Pooled Analysis of 4 Randomized Trials Comparing Sirolimus-Eluting Stents With Bare-Metal Stents. Journal Of The American College Of Cardiology 2009, 54: 894-902. PMID: 19712798, DOI: 10.1016/j.jacc.2009.04.077.Peer-Reviewed Original ResearchConceptsBare metal stentsTarget vessel revascularizationStent thrombosisRate of deathMyocardial infarctionVessel revascularizationPooled analysisAcademic Research Consortium definitionsPatient-level pooled analysisDrug-eluting stent implantationArterial healing responseComposite of deathProbable stent thrombosisLong-term safetyDrug-eluting stentsLate stent thrombosisClinical outcomesRandomized trialsStent implantationSuperior efficacyBMS groupThrombosisHealing responseSES groupStentsImpact of Thienopyridine Administration Prior to Primary Stenting in Acute Myocardial Infarction
RABBANI LE, IYENGAR S, DANGAS GD, GRINES CL, COX DA, GARCIA E, TCHENG JE, GRIFFIN JJ, GUAGLIUMI G, STUCKEY T, TURCO M, STANT J, FAHY M, LANSKY AJ, MEHRAN R, STONE GW. Impact of Thienopyridine Administration Prior to Primary Stenting in Acute Myocardial Infarction. Journal Of Interventional Cardiology 2009, 22: 378-384. PMID: 19496901, DOI: 10.1111/j.1540-8183.2009.00474.x.Peer-Reviewed Original ResearchMeSH KeywordsAbciximabAgedAngioplasty, Balloon, CoronaryAntibodies, MonoclonalAspirinConfidence IntervalsDrug Therapy, CombinationDrug-Eluting StentsFemaleHumansImmunoglobulin Fab FragmentsKaplan-Meier EstimateMaleMiddle AgedMultivariate AnalysisMyocardial InfarctionMyocardial RevascularizationOdds RatioPlatelet Aggregation InhibitorsPreoperative CarePyridinesTime FactorsConceptsMajor adverse cardiovascular eventsAcute myocardial infarctionTarget vessel revascularizationIschemic target vessel revascularizationPrimary stentingThienopyridine administrationLoading doseTH patientsStent implantationMyocardial infarctionClopidogrel loading doseAdverse cardiovascular eventsSuperior clinical outcomesBare-metal stentingAbciximab useCADILLAC trialCardiovascular eventsVessel revascularizationClinical outcomesMetal stentingProcedural characteristicsOperator's discretionPatientsStentingCore lab
2008
Comparison between ticlopidine and clopidogrel in patients undergoing primary stenting in acute myocardial infarction: Results from the CADILLAC trial
Lansky AJ, Tsuchiya Y, Brener M, Mehran R, Cristea E, Pietras C, Grines CL, Cox DA, Garcia E, Tcheng JE, Guagliumi G, Stuckey T, Turco M, Carroll JD, Rutherford BD, Leon MB, Moses J, Stone GW. Comparison between ticlopidine and clopidogrel in patients undergoing primary stenting in acute myocardial infarction: Results from the CADILLAC trial. Catheterization And Cardiovascular Interventions 2008, 72: 917-924. PMID: 19016469, DOI: 10.1002/ccd.21714.Peer-Reviewed Original ResearchMeSH KeywordsAbciximabAgedAngioplasty, Balloon, CoronaryAntibodies, MonoclonalAspirinClopidogrelCoronary AngiographyDrug Therapy, CombinationEuropeFemaleHemorrhageHumansImmunoglobulin Fab FragmentsMaleMiddle AgedMulticenter Studies as TopicMyocardial InfarctionMyocardial IschemiaPlatelet Aggregation InhibitorsRandomized Controlled Trials as TopicRetrospective StudiesRisk AssessmentStentsThrombosisTiclopidineTime FactorsTreatment OutcomeUnited StatesConceptsAcute myocardial infarctionPrimary stentingCADILLAC trialRecurrent ischemiaSevere bleedingMyocardial infarctionEfficacy of clopidogrelMore recurrent ischemiaTIMI 0/1 flowSimilar clinical outcomesTiclopidine treatmentAngiographic characteristicsClopidogrel useIndependent predictorsClinical outcomesMultivariable analysisRandomized trialsStent thrombosisStent implantationOperator's discretionClopidogrelStentingPatientsTiclopidineRelative safetyTreatment of diffuse IN-stent restenosis with Drug-Eluting stents vs. intracoronary bEta-raDiation therapy: INDEED Study
Park SW, Lee SW, Koo B, Park DW, Lee SW, Kim YH, Lee CW, Hong MK, Kim JJ, Mori K, Lansky AJ, Mintz GS, Lee MM, Park SJ. Treatment of diffuse IN-stent restenosis with Drug-Eluting stents vs. intracoronary bEta-raDiation therapy: INDEED Study. International Journal Of Cardiology 2008, 131: 70-77. PMID: 18190986, DOI: 10.1016/j.ijcard.2007.09.003.Peer-Reviewed Original ResearchConceptsMajor adverse cardiac eventsIntracoronary brachytherapySES implantationMyocardial infarctionGroup IILate lossGroup IDiffuse ISRAngiographic restenosisSirolimus-eluting stent implantationEnd pointMore effective treatment modalitiesBare-metal ISRAdverse cardiac eventsPrimary end pointSecondary end pointsEffective treatment modalityIn-Stent RestenosisDrug-eluting stentsLesion revascularizationBaseline characteristicsCardiac eventsCardiac deathLower restenosisStent implantationAngiographic Surrogate End Points in Drug-Eluting Stent Trials A Systematic Evaluation Based on Individual Patient Data From 11 Randomized, Controlled Trials
Pocock SJ, Lansky AJ, Mehran R, Popma JJ, Fahy MP, Na Y, Dangas G, Moses JW, Pucelikova T, Kandzari DE, Ellis SG, Leon MB, Stone GW. Angiographic Surrogate End Points in Drug-Eluting Stent Trials A Systematic Evaluation Based on Individual Patient Data From 11 Randomized, Controlled Trials. Journal Of The American College Of Cardiology 2008, 51: 23-32. PMID: 18174032, DOI: 10.1016/j.jacc.2007.07.084.Peer-Reviewed Original ResearchConceptsDrug-eluting stentsBare metal stentsAngiographic measuresTLR riskEnd pointDifferent drug-eluting stentsPrimary end pointRisk of TLRFollow-up angiographyLower revascularization ratesSurrogate end pointsIndividual patient dataSuitable surrogate markerDES trialsRevascularization ratesTLR rateClinical restenosisControlled TrialsFuture trialsStent implantationStent trialsSurrogate marker
2007
Gender-Specific Outcomes After Sirolimus-Eluting Stent Implantation
Solinas E, Nikolsky E, Lansky AJ, Kirtane AJ, Morice MC, Popma JJ, Schofer J, Schampaert E, Pucelikova T, Aoki J, Fahy M, Dangas GD, Moses JW, Cutlip DE, Leon MB, Mehran R. Gender-Specific Outcomes After Sirolimus-Eluting Stent Implantation. Journal Of The American College Of Cardiology 2007, 50: 2111-2116. PMID: 18036446, DOI: 10.1016/j.jacc.2007.06.056.Peer-Reviewed Original ResearchConceptsSirolimus-eluting stentsBare metal stentsSegment binary restenosisBinary restenosisClinical outcomesMajor adverse cardiac eventsSirolimus-Eluting Stent ImplantationAdverse cardiac eventsOutcomes of patientsTarget vessel revascularizationCongestive heart failureOutcomes of womenPercutaneous coronary interventionOverall clinical outcomeGender-specific differencesVessel revascularizationCardiac eventsCoronary interventionAngiographic featuresDiabetes mellitusHeart failureIndependent predictorsMultivariable analysisClinical benefitStent implantation
2006
Volumetric Intravascular Ultrasound Assessment of Neointimal Hyperplasia and Nonuniform Stent Strut Distribution in Sirolimus-Eluting Stent Restenosis
Sano K, Mintz GS, Carlier SG, Fujii K, Takebayashi H, Kimura M, Costa JR, Tanaka K, Costa RA, Lui J, Weisz G, Moussa I, Dangas GD, Mehran R, Lansky AJ, Kreps EM, Collins M, Stone GW, Moses JW, Leon MB. Volumetric Intravascular Ultrasound Assessment of Neointimal Hyperplasia and Nonuniform Stent Strut Distribution in Sirolimus-Eluting Stent Restenosis. The American Journal Of Cardiology 2006, 98: 1559-1562. PMID: 17145209, DOI: 10.1016/j.amjcard.2006.07.030.Peer-Reviewed Original ResearchConceptsMinimum lumen siteStent restenotic lesionsStent areaDiabetes mellitusLumen areaRestenotic lesionsStent strut distributionIH areaMinimal lumen area siteSirolimus-eluting stent implantationVolumetric intravascular ultrasound analysisIntravascular ultrasound assessmentMinimum stent areaIntravascular ultrasound analysisMinimum lumen areaMinimal lumen areaMinimal lumen siteIH responseSES implantationStent implantationUltrasound assessmentStent lengthNeointimal hyperplasiaStent restenosisStrut distributionOutcome After Acute Incomplete Sirolimus-Eluting Stent Apposition as Assessed by Serial Intravascular Ultrasound
Kimura M, Mintz GS, Carlier S, Takebayashi H, Fujii K, Sano K, Yasuda T, Costa RA, Costa JR, Quen J, Tanaka K, Lui J, Weisz G, Moussa I, Dangas G, Mehran R, Lansky AJ, Kreps EM, Collins M, Stone GW, Moses JW, Leon MB. Outcome After Acute Incomplete Sirolimus-Eluting Stent Apposition as Assessed by Serial Intravascular Ultrasound. The American Journal Of Cardiology 2006, 98: 436-442. PMID: 16893693, DOI: 10.1016/j.amjcard.2006.02.050.Peer-Reviewed Original ResearchConceptsIncomplete stent appositionSES implantationStent appositionSirolimus-eluting stent implantationComplete resolution groupIntravascular ultrasound findingsIncidence of restenosisSerial intravascular ultrasoundConsecutive patientsStent thrombosisStent implantationUltrasound findingsPlaque areaAneurysm formationStent restenosisIntravascular ultrasoundPatientsLumen areaStent strutsGreater decreaseVessel wallThrombosisRestenosisLesionsGreater increase