2024
Privacy-Preserving Visualization of Brain Functional Network Connectivity
Tao Y, Sarwate A, Panta S, Plis S, Calhoun V. Privacy-Preserving Visualization of Brain Functional Network Connectivity. 2024, 00: 1-5. DOI: 10.1109/isbi56570.2024.10635222.Peer-Reviewed Original ResearchDifferential privacyProtecting sensitive informationNon-private counterpartsPre-and post-processingPrivacy-preservingPrivacy guaranteesSensitive informationPrivacy costData visualizationPrivacyBiomedical dataInvestigate several approachesNetwork connectivityPost-processingSeveral approachesVisualizationWorkflowGuaranteesCorrelation valuesTradeoffDataConnectogramsInformation
2022
Effectuality study of a 3D motion correction algorithm in C-arm CTs of severely impaired image quality during transarterial chemoembolization
Becker L, Dewald C, von Falck C, Werncke T, Maschke S, Kloeckner R, Wacker F, Meyer B, Hinrichs J. Effectuality study of a 3D motion correction algorithm in C-arm CTs of severely impaired image quality during transarterial chemoembolization. Cancer Imaging 2022, 22: 37. PMID: 35908026, PMCID: PMC9338620, DOI: 10.1186/s40644-022-00473-3.Peer-Reviewed Original Research
2019
PET Image Deblurring and Super-Resolution With an MR-Based Joint Entropy Prior
Song T, Yang F, Chowdhury S, Kim K, Johnson K, Fakhri G, Li Q, Dutta J. PET Image Deblurring and Super-Resolution With an MR-Based Joint Entropy Prior. IEEE Transactions On Computational Imaging 2019, 5: 530-539. PMID: 31723575, PMCID: PMC6853071, DOI: 10.1109/tci.2019.2913287.Peer-Reviewed Original ResearchContrast-to-noise ratioStructural similarity indexHoffman phantomImage deblurringDigital phantomPhantom studyPeak signal-to-noise ratioSuper-resolution frameworkQuantitative accuracySimilarity indexSignal-to-noise ratioSpatial resolutionPhantomImage quantitationSuper-ResolutionTau imaging studiesImage qualityPET imagingDeblurringHigh-resolution MR imagingRoot mean square errorSimulation studyBrainWebPost-processingPenalty function
2003
Real‐Time Three‐Dimensional Echocardiography Using a Novel Matrix Array Transducer
Sugeng L, Weinert L, Thiele K, Lang R. Real‐Time Three‐Dimensional Echocardiography Using a Novel Matrix Array Transducer. Echocardiography 2003, 20: 623-635. PMID: 14536013, DOI: 10.1046/j.1540-8175.2003.t01-1-03031.x.Peer-Reviewed Original ResearchConceptsThree-dimensional echocardiographyReal-time three-dimensional echocardiographyTwo-dimensional echocardiographyVolume-rendered reconstructionsMatrix array probeEchocardiographyClinical useUltrasound unitClinical applicationMatrix array transducerReal-time three-dimensional imagingData acquisitionReal-time methodThree-dimensional data acquisitionReview current methodsThree-dimensional imagesPost-processing
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply