2019
Body motion detection and correction in cardiac PET: Phantom and human studies
Sun T, Petibon Y, Han P, Ma C, Kim S, Alpert N, Fakhri G, Ouyang J. Body motion detection and correction in cardiac PET: Phantom and human studies. Medical Physics 2019, 46: 4898-4906. PMID: 31508827, PMCID: PMC6842053, DOI: 10.1002/mp.13815.Peer-Reviewed Original ResearchConceptsList-mode dataMotion-compensated image reconstructionMotion correctionCenter of massPET list-mode dataMotion correction methodMotion detectionMotion estimationImage reconstructionPatient body motionDegrade image qualityNonrigid registrationImage qualityMotion transformationCoincident distributionBody motion detectionCardiac positron emission tomographyBack-projection techniqueCovariance matrixImage volumesBody motionPositron emission tomographyBack-projectionReference framePhantom
2017
Non-Rigid Event-by-Event Continuous Respiratory Motion Compensated List-Mode Reconstruction for PET
Chan C, Onofrey J, Jian Y, Germino M, Papademetris X, Carson RE, Liu C. Non-Rigid Event-by-Event Continuous Respiratory Motion Compensated List-Mode Reconstruction for PET. IEEE Transactions On Medical Imaging 2017, 37: 504-515. PMID: 29028189, PMCID: PMC7304524, DOI: 10.1109/tmi.2017.2761756.Peer-Reviewed Original ResearchConceptsMotion-compensated image reconstructionMotion fieldImage reconstructionReconstruction algorithmRespiratory motionNon-rigid motionNon-rigid motion correctionSignificant image blurringSystem matrixMotion correctionSystem matrix calculationMotionImage blurringSuperior image qualityTracer concentrationRigid motionReference locationMatrix calculationList-mode reconstruction algorithmMotion correlationDynamics studyImage quality
2014
Accuracy of Respiratory Motion Compensated Image Reconstruction Using 4DPET-Derived Deformation Fields
Dutta J, Chelala M, Shao X, Lorsakul A, Li Q, Fakhri G. Accuracy of Respiratory Motion Compensated Image Reconstruction Using 4DPET-Derived Deformation Fields. 2014, 1-4. DOI: 10.1109/nssmic.2014.7430924.Peer-Reviewed Original ResearchAttenuation-corrected PET imagesXCAT phantomNon-attenuation-corrected PET imagesMotion-compensated image reconstructionImage reconstructionMotion informationPET imagingMotion estimationPET gatingAttenuation mapBreathing motionPET quantitationSoftware GATEXCATDeformation fieldPhantomAccuracy of motionGround truthGateAnatomical imagesFieldMotionUpper abdomenPulmonary lesionsMonte
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply