2022
Emergency department initiated resuscitative endovascular balloon occlusion of the aorta (REBOA) for out‐of‐hospital cardiac arrest is feasible and associated with improvements in end‐tidal carbon dioxide
Daley J, Buckley R, Kisken KC, Barber D, Ayyagari R, Wira C, Aydin A, Latich I, Lozada JCP, Joseph D, Marino A, Mojibian H, Pollak J, Chaar CO, Bonz J, Belsky J, Coughlin R, Liu R, Sather J, Van Tonder R, Beekman R, Fults E, Johnson A, Moore C. Emergency department initiated resuscitative endovascular balloon occlusion of the aorta (REBOA) for out‐of‐hospital cardiac arrest is feasible and associated with improvements in end‐tidal carbon dioxide. Journal Of The American College Of Emergency Physicians Open 2022, 3: e12791. PMID: 36176506, PMCID: PMC9463569, DOI: 10.1002/emp2.12791.Peer-Reviewed Original ResearchAdvanced cardiac life supportResuscitative endovascular balloon occlusionEnd-tidal carbon dioxideHospital cardiac arrestEndovascular balloon occlusionAortic occlusionCardiac life supportOHCA patientsBalloon occlusionCardiac arrestEmergency departmentLife supportAcademic urban EDEarly feasibility trialUrban ED settingIntra-aortic balloonTidal carbon dioxideReperfusion strategyHospital admissionSpontaneous circulationUrban EDED settingFeasibility trialBalloon deflationChest compressions
2013
Comparação da retração aguda do stent entre o suporte vascular bioabsorvível eluidor de everolimus e dois diferentes stents metálicos farmacológicos
Borghi T, Costa J, Abizaid A, Chamié D, Veloso e Silva M, Taiguara D, Costa R, Staico R, Feres F, Chaves Á, Siqueira D, Sousa A, Sousa J. Comparação da retração aguda do stent entre o suporte vascular bioabsorvível eluidor de everolimus e dois diferentes stents metálicos farmacológicos. Journal Of Transcatheter Interventions 2013, 21: 326-331. DOI: 10.1590/s2179-83972013000400005.Peer-Reviewed Original ResearchMetallic drug-eluting stentsPercutaneous coronary interventionDrug-eluting stentsBioresorbable vascular scaffoldAcute recoilSecond-generation metallic drug-eluting stentsAcute luminal gainNon-complex lesionsAngiographic characteristicsNo significant differenceEverolimus-eluting stentPolymeric materialsMaximum inflation pressureCoronary interventionBalloon deflationStentCobalt-chromium everolimus-eluting stentPatientsSignificant differenceVascular scaffoldsBiolimus-eluting stentInflation pressureLuminal gainHealing processBalloon
1990
Reduction of myocardial ischemia during percutaneous transluminal coronary angioplasty with oxygenated Fluosol®11Fluosol® (20% Intravascular Perfluorochemical Emulsion) is a registered trademark of The Green Cross Corporation, Osaka, Japan.
Kent K, Cleman M, Cowley M, Forman M, Jaffe C, Kaplan M, King S, Krucoff M, Lassar T, McAuley B, Smith R, Wisdom C, Wohlgelernter D. Reduction of myocardial ischemia during percutaneous transluminal coronary angioplasty with oxygenated Fluosol®11Fluosol® (20% Intravascular Perfluorochemical Emulsion) is a registered trademark of The Green Cross Corporation, Osaka, Japan. The American Journal Of Cardiology 1990, 66: 279-284. PMID: 2195864, DOI: 10.1016/0002-9149(90)90836-p.Peer-Reviewed Original ResearchConceptsOxygen-carrying perfluorochemical emulsionFluosol perfusionAngioplasty patientsMyocardial ischemiaPerfluorochemical emulsionBaseline levelsGlobal left ventricular ejection fractionLeft ventricular ejection fractionPercutaneous transluminal coronary angioplastyRegional wall dysfunctionSevere anginal painTransluminal coronary angioplastyVentricular ejection fractionST-segment changesAnginal painGreen Cross CorporationCoronary angioplastyEjection fractionMulticenter trialRoutine angioplastyVentricular functionBalloon occlusionBalloon deflationPatient populationBalloon inflation
1988
Dynamics of early and late left ventricular filling determined by Doppler two-dimensional echocardiography during percutaneous transluminal coronary angioplasty
Bowman L, Cleman M, Cabin H, Zaret B, Jaffe C. Dynamics of early and late left ventricular filling determined by Doppler two-dimensional echocardiography during percutaneous transluminal coronary angioplasty. The American Journal Of Cardiology 1988, 61: 541-545. PMID: 2964191, DOI: 10.1016/0002-9149(88)90761-8.Peer-Reviewed Original ResearchConceptsPercutaneous transluminal coronary angioplastyEarly peak filling ratePeak filling rateLate filling ratioTransluminal coronary angioplastyAtrial stroke volumeLeft ventricular fillingBalloon inflationVentricular fillingCoronary angioplastyStroke volumeMean pulmonary artery wedge pressureDominant right coronary arteryPulmonary artery wedge pressureLate ventricular fillingRight coronary arteryGlobal systolic functionTwo-dimensional echocardiographyInfluence of ischemiaFilling rateWedge pressureLeft circumflexSystolic functionCoronary occlusionBalloon deflation
1985
A simple method for reducing cardiac output in the conscious lamb
Fahey J, Lister G. A simple method for reducing cardiac output in the conscious lamb. American Journal Of Physiology 1985, 249: h188-h192. PMID: 4014483, DOI: 10.1152/ajpheart.1985.249.1.h188.Peer-Reviewed Original ResearchConceptsCardiac outputBalloon inflationBalloon-tipped catheterSystemic venous returnArterial lactate concentrationSystemic blood flowResting cardiac outputSmall neck incisionStable cardiac outputDays of ageUnsedated lambsConscious lambsBlood pressureVenous returnBalloon deflationNeck incisionRight atriumJugular veinMetabolic variablesO2 extractionBlood flowAnimal survivalLactate concentrationO2 consumptionLambs
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply