Featured Publications
Transcatheter Aortic Valve Replacement in Bicuspid Versus Tricuspid Aortic Valves From the STS/ACC TVT Registry
Forrest JK, Kaple RK, Ramlawi B, Gleason TG, Meduri CU, Yakubov SJ, Jilaihawi H, Liu F, Reardon MJ. Transcatheter Aortic Valve Replacement in Bicuspid Versus Tricuspid Aortic Valves From the STS/ACC TVT Registry. JACC Cardiovascular Interventions 2020, 13: 1749-1759. PMID: 32473890, DOI: 10.1016/j.jcin.2020.03.022.Peer-Reviewed Original ResearchMeSH KeywordsAgedAged, 80 and overAortic Valve StenosisBicuspid Aortic Valve DiseaseFemaleHeart Valve ProsthesisHemodynamicsHumansMaleMiddle AgedPostoperative ComplicationsProsthesis DesignRecovery of FunctionRegistriesRetrospective StudiesRisk AssessmentRisk FactorsTime FactorsTranscatheter Aortic Valve ReplacementTreatment OutcomeUnited StatesConceptsAortic valve stenosisBicuspid aortic valve stenosisTranscatheter aortic valve replacementEvolut PRO valveAortic valve replacementValve stenosisTVT RegistryCause mortalityValve replacementEvolut RBicuspid valveBicuspid Versus Tricuspid Aortic ValvesSTS/ACC TVT RegistryThoracic Surgeons/American CollegeTricuspid aortic valve stenosisCardiology TVT (Transcatheter Valve Therapy) RegistryTricuspid aortic stenosisRate of strokeSelf-expanding valvesLow complication rateTricuspid aortic valveAcceptable safety outcomesCardiac comorbiditiesEchocardiographic outcomesAortic stenosis
2021
TCT-147 Transcatheter Aortic Valve Replacement in Large Annuli Valves With the Supra-Annular, Self-Expandable Evolut Platform: Insights From the STS/ACC TVT Registry
Dallan L, Tang G, Reardon M, Forrest J, Szeto W, Kodali S, Eisenberg R, Attizzani G. TCT-147 Transcatheter Aortic Valve Replacement in Large Annuli Valves With the Supra-Annular, Self-Expandable Evolut Platform: Insights From the STS/ACC TVT Registry. Journal Of The American College Of Cardiology 2021, 78: b60. DOI: 10.1016/j.jacc.2021.09.997.Peer-Reviewed Original ResearchNATIONAL TRENDS OF PERMANENT PACEMAKER IMPLANTATION AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT: AN ANALYSIS FROM THE STS/ACC TVT REGISTRY
Chau K, George I, Vemulapalli S, Wegermann Z, Forrest J, Yakubov S, Williams M, Manandhar P, Vahl T, Leon M, Kodali S, Kirtane A, Nazif T. NATIONAL TRENDS OF PERMANENT PACEMAKER IMPLANTATION AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT: AN ANALYSIS FROM THE STS/ACC TVT REGISTRY. Journal Of The American College Of Cardiology 2021, 77: 918. DOI: 10.1016/s0735-1097(21)02277-4.Peer-Reviewed Original ResearchOutcomes of Prosthesis-Patient Mismatch Following Supra-Annular Transcatheter Aortic Valve Replacement From the STS/ACC TVT Registry
Tang GHL, Sengupta A, Alexis SL, Bapat VN, Adams DH, Sharma SK, Kini AS, Kodali SK, Ramlawi B, Gada H, Vora AN, Forrest JK, Kaple RK, Liu F, Reardon MJ. Outcomes of Prosthesis-Patient Mismatch Following Supra-Annular Transcatheter Aortic Valve Replacement From the STS/ACC TVT Registry. JACC Cardiovascular Interventions 2021, 14: 964-976. PMID: 33958170, DOI: 10.1016/j.jcin.2021.03.040.Peer-Reviewed Original ResearchConceptsSevere prosthesis-patient mismatchTranscatheter aortic valve replacementProsthesis-patient mismatchDe novo stenosisAortic valve replacementTVT RegistryNovo stenosisValve replacementSTS/ACC TVT RegistryHigh residual gradientPre-procedural factorsLong-term outcomesAortic gradientAortic annulusClinical outcomesSurgical bioprosthesesAdverse outcomesClinical impactPatientsResidual gradientReadmissionRegistryMortalityLinear mixed modelsOutcomes
2020
Three Generations of Self-Expanding Transcatheter Aortic Valves A Report From the STS/ACC TVT Registry
Forrest JK, Kaple RK, Tang GHL, Yakubov SJ, Nazif TM, Williams MR, Zhang A, Popma JJ, Reardon MJ. Three Generations of Self-Expanding Transcatheter Aortic Valves A Report From the STS/ACC TVT Registry. JACC Cardiovascular Interventions 2020, 13: 170-179. PMID: 31973793, DOI: 10.1016/j.jcin.2019.08.035.Peer-Reviewed Original ResearchMeSH KeywordsAgedAged, 80 and overAortic ValveAortic Valve InsufficiencyAortic Valve StenosisBioprosthesisFemaleHeart Valve ProsthesisHemodynamicsHumansMaleProsthesis DesignRecovery of FunctionRegistriesRetrospective StudiesRisk AssessmentRisk FactorsSeverity of Illness IndexTime FactorsTranscatheter Aortic Valve ReplacementTreatment OutcomeUnited StatesConceptsEvolut PRO valveTranscatheter aortic valveTVT RegistryAortic regurgitationEvolut RAortic valveSelf-expanding transcatheter aortic valveSTS/ACC TVT RegistryThoracic Surgeons/American CollegeMean aortic valve gradientTranscatheter aortic valve replacement (TAVR) technologyCardiology TVT (Transcatheter Valve Therapy) RegistryTricuspid aortic stenosisAortic valve gradientSignificant aortic regurgitationMild aortic regurgitationSupra-annular valveTranscatheter valve technologyValve gradientHemodynamic statusAortic stenosisAortic annulusEarly outcomesEchocardiographic dataPatient risk
2019
TCT-752 Incidence and Outcomes of Patient-Prosthesis Mismatch Following Self-Expanding Transcatheter Aortic Valve Replacement: An Analysis From the STS/ACC TVT Registry
Tang G, Bapat V, Popma J, Adams D, Kodali S, Ramlawi B, Gada H, Forrest J, Kaple R, Reardon M. TCT-752 Incidence and Outcomes of Patient-Prosthesis Mismatch Following Self-Expanding Transcatheter Aortic Valve Replacement: An Analysis From the STS/ACC TVT Registry. Journal Of The American College Of Cardiology 2019, 74: b738. DOI: 10.1016/j.jacc.2019.08.890.Peer-Reviewed Original ResearchPredictors and Risk Calculator of Early Unplanned Hospital Readmission Following Contemporary Self-Expanding Transcatheter Aortic Valve Replacement from the STS/ACC TVT Registry
Sanchez CE, Hermiller JB, Pinto DS, Chetcuti SJ, Arshi A, Forrest JK, Huang J, Yakubov SJ. Predictors and Risk Calculator of Early Unplanned Hospital Readmission Following Contemporary Self-Expanding Transcatheter Aortic Valve Replacement from the STS/ACC TVT Registry. Cardiovascular Revascularization Medicine 2019, 21: 263-270. PMID: 31255552, DOI: 10.1016/j.carrev.2019.05.032.Peer-Reviewed Original ResearchConceptsMajor vascular complicationsAdvanced heart failure symptomsEarly hospital readmissionHeart failure symptomsHigh-risk subsetHospital readmissionMitral valve regurgitationReadmission riskVascular complicationsTVT RegistryUnplanned readmissionHome oxygenValve regurgitationAtrial fibrillationMultivariable predictorsValidation cohortDischarge planningRisk calculatorFailure symptomsSelf-expanding transcatheter aortic valve replacementSTS/ACC TVT RegistryEarly unplanned hospital readmissionTranscatheter aortic valve replacementIndex hospitalization lengthAcute kidney injury
2018
TCT-184 30-Day Outcomes Following Transcatheter Aortic Valve Replacement with The Evolut PRO Valve in Commercial Use: Report from the STS/ACC TVT Registry
Forrest J, Williams M, Popma J, Reardon M. TCT-184 30-Day Outcomes Following Transcatheter Aortic Valve Replacement with The Evolut PRO Valve in Commercial Use: Report from the STS/ACC TVT Registry. Journal Of The American College Of Cardiology 2018, 72: b78. DOI: 10.1016/j.jacc.2018.08.1299.Peer-Reviewed Original Research