Featured Publications
Propensity-Matched Outcomes Comparing TAVR in Bicuspid vs Surgery in Tricuspid Aortic Valve Stenosis
Deeb G, Yakubov S, Reardon M, Ramlawi B, Chetcuti S, Kleiman N, Zahr F, Song H, Gada H, Mumtaz M, Ito S, Huang J, Forrest J. Propensity-Matched Outcomes Comparing TAVR in Bicuspid vs Surgery in Tricuspid Aortic Valve Stenosis. Journal Of The Society For Cardiovascular Angiography & Interventions 2022, 2: 100525. PMID: 39132531, PMCID: PMC11307701, DOI: 10.1016/j.jscai.2022.100525.Peer-Reviewed Original ResearchTranscatheter aortic valve replacementSurgical aortic valve replacementAortic valve stenosisTricuspid aortic valve stenosisBicuspid aortic valve stenosisAortic valve replacementSAVR patientsValve replacementValve stenosisEvolut Low Risk trialIndependent clinical events committeeLow-risk trialsSerious adverse eventsSevere aortic regurgitationClinical events committeeLow surgical riskLow-risk patientsIndependent core laboratoryEffective orifice areaTAVR groupValve gradientAdverse eventsAortic regurgitationSurgical riskEvents committee
2022
Propensity-Matched 1-Year Outcomes Following Transcatheter Aortic Valve Replacement in Low-Risk Bicuspid and Tricuspid Patients
Deeb GM, Reardon MJ, Ramlawi B, Yakubov SJ, Chetcuti SJ, Kleiman NS, Mangi AA, Zahr F, Song HK, Gada H, Mumtaz M, Heiser J, Merhi W, Murrah CP, Noel T, Kirshner M, Byrne T, Ito S, Huang J, Forrest JK. Propensity-Matched 1-Year Outcomes Following Transcatheter Aortic Valve Replacement in Low-Risk Bicuspid and Tricuspid Patients. JACC Cardiovascular Interventions 2022, 15: 511-522. PMID: 35272776, DOI: 10.1016/j.jcin.2021.10.027.Peer-Reviewed Original ResearchConceptsTranscatheter aortic valve replacementAortic valve replacementValve replacementAortic stenosisTricuspid patientsOutcomes Following Transcatheter Aortic Valve ReplacementEvolut Low Risk trialLow surgical risk patientsIndependent clinical events committeeBicuspid aortic stenosisLow-risk trialsSurgical risk patientsTricuspid aortic stenosisPropensity-matched groupsSerious adverse eventsClinical events committeeIndependent core laboratoryBicuspid aortic valveEffective orifice areaTricuspid groupCause mortalityPrimary endpointTAVR patientsAdverse eventsRisk patients
2020
Three-Year Outcomes With a Contemporary Self-Expanding Transcatheter Valve From the Evolut PRO US Clinical Study
Wyler von Ballmoos MC, Reardon MJ, Williams MR, Mangi AA, Kleiman NS, Yakubov SJ, Watson D, Kodali S, George I, Tadros P, Zorn GL, Brown J, Kipperman R, Oh JK, Qiao H, Forrest JK. Three-Year Outcomes With a Contemporary Self-Expanding Transcatheter Valve From the Evolut PRO US Clinical Study. Cardiovascular Revascularization Medicine 2020, 26: 12-16. PMID: 33199247, DOI: 10.1016/j.carrev.2020.11.007.Peer-Reviewed Original ResearchConceptsTranscatheter aortic valve replacementEvolut PRO valveParavalvular regurgitationUS clinical studiesCause mortalityClinical studiesNew York Heart Association class ISelf-expanding transcatheter valveValve Academic Research ConsortiumExtreme surgical riskMild paravalvular regurgitationAcademic Research ConsortiumAortic valve replacementIndependent core laboratoryThree-Year OutcomesSelf-expanding prosthesisLong-term resultsEffective orifice areaValve thrombosisCardiovascular mortalityExcellent hemodynamicsValve replacementEchocardiographic measuresSurgical riskTranscatheter valve
2017
1-Year Results in Patients Undergoing Transcatheter Aortic Valve Replacement With Failed Surgical Bioprostheses
Deeb GM, Chetcuti SJ, Reardon MJ, Patel HJ, Grossman PM, Schreiber T, Forrest JK, Bajwa TK, O’Hair D, Petrossian G, Robinson N, Katz S, Hartman A, Dauerman HL, Schmoker J, Khabbaz K, Watson DR, Yakubov SJ, Oh JK, Li S, Kleiman NS, Adams DH, Popma JJ. 1-Year Results in Patients Undergoing Transcatheter Aortic Valve Replacement With Failed Surgical Bioprostheses. JACC Cardiovascular Interventions 2017, 10: 1034-1044. PMID: 28521921, DOI: 10.1016/j.jcin.2017.03.018.Peer-Reviewed Original ResearchMeSH KeywordsAgedAged, 80 and overAortic ValveAortic Valve InsufficiencyAortic Valve StenosisEchocardiographyFemaleHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHemodynamicsHumansKaplan-Meier EstimateMaleMiddle AgedProspective StudiesProsthesis FailureQuality of LifeRecovery of FunctionRecurrenceReoperationRisk FactorsTime FactorsTranscatheter Aortic Valve ReplacementTreatment OutcomeConceptsSelf-expanding transcatheter aortic valve replacementTranscatheter aortic valve replacementAortic valve replacementMajor stroke rateAortic regurgitationValve replacementStroke rateValve hemodynamicsSevere native aortic valve stenosisSuccessful transcatheter aortic valve replacementNative aortic valve stenosisNew permanent pacemaker implantationSevere residual aortic regurgitationValve prosthesis-patient mismatchMean aortic gradientMean valve gradientResidual aortic regurgitationSevere aortic regurgitationProsthesis-patient mismatchCause mortality ratesIndependent core laboratoryModerate aortic regurgitationPermanent pacemaker implantationAortic valve stenosisAortic valve hemodynamics