2024
Flat Panel TOF-PET Detectors: a Simulation Study
Orehar M, Dolenec R, Fakhri G, Gascón D, Gola A, Korpar S, Križan P, Razdevšek G, Marin T, Chemli Y, Žontar D, Pestotnik R. Flat Panel TOF-PET Detectors: a Simulation Study. 2024, 00: 1-2. DOI: 10.1109/nss/mic/rtsd57108.2024.10658250.Peer-Reviewed Original ResearchTime resolutionAngular coverageFlat-panel detectorScintillation materialsGATE softwareAxial coverageBiograph VisionPanel detectorTotal-body coverageClinical scannerImage reconstructionDetectorReconstructed imagesHomogeneous contrastCylindrical scannerImage qualityState-of-the-artScintillationHigh-performance computingScannerPhantomResolutionCore hoursPositron emission tomographyGate
2023
Impact of motion correction on [18F]-MK6240 tau PET imaging
Tiss A, Marin T, Chemli Y, Spangler-Bickell M, Gong K, Lois C, Petibon Y, Landes V, Grogg K, Normandin M, Becker A, Thibault E, Johnson K, Fakhri G, Ouyang J. Impact of motion correction on [18F]-MK6240 tau PET imaging. Physics In Medicine And Biology 2023, 68: 105015. PMID: 37116511, PMCID: PMC10278956, DOI: 10.1088/1361-6560/acd161.Peer-Reviewed Original ResearchConceptsMotion correctionPET quantitationImpact of motion correctionList-mode reconstructionMotion correction methodList-mode dataMotion-corrected imagesEffect of motion correctionVoxel displacementsPhantom experimentsOptical tracking dataLong acquisitionBrain PET scansSlow motionImage qualityPET imagingPositron emission tomographyCorrectionMotionCorrection methodRates of tau accumulationHead motionMotion metricsPhantomPositronSuper-resolution in brain positron emission tomography using a real-time motion capture system
Chemli Y, Tétrault M, Marin T, Normandin M, Bloch I, El Fakhri G, Ouyang J, Petibon Y. Super-resolution in brain positron emission tomography using a real-time motion capture system. NeuroImage 2023, 272: 120056. PMID: 36977452, PMCID: PMC10122782, DOI: 10.1016/j.neuroimage.2023.120056.Peer-Reviewed Original ResearchConceptsBrain positron emission tomographySuper-resolutionEvent-by-event basisReal-time motion capture systemSR reconstruction methodTracking cameraVisualization of small structuresPET reconstruction algorithmMoving phantomMeasure target motionLine profilesPET/CT scannerMeasured shiftsImprove image resolutionMotion capture systemMotion tracking devicePositron emission tomographyReconstruction algorithmSpatial resolutionMeasured linesPhantomReal-timeEstimation frameworkIncreased spatial resolutionReconstruction method