1998
Efficacy of Coronary Stenting Versus Balloon Angioplasty in Small Coronary Arteries fn1fn1This study was supported in part by a grant from Johnson & Johnson Interventional Systems, Inc., Warren, New Jersey.
Savage M, Fischman D, Rake R, Leon M, Schatz R, Penn I, Nobuyoshi M, Moses J, Hirshfeld J, Heuser R, Baim D, Cleman M, Brinker J, Gebhardt S, Goldberg S, Investigators F. Efficacy of Coronary Stenting Versus Balloon Angioplasty in Small Coronary Arteries fn1fn1This study was supported in part by a grant from Johnson & Johnson Interventional Systems, Inc., Warren, New Jersey. Journal Of The American College Of Cardiology 1998, 31: 307-311. PMID: 9462572, DOI: 10.1016/s0735-1097(97)00511-1.Peer-Reviewed Original ResearchMeSH KeywordsAngioplasty, Balloon, CoronaryChi-Square DistributionCohort StudiesCoronary AngiographyCoronary DiseaseCoronary VesselsDisease-Free SurvivalElective Surgical ProceduresEquipment DesignFemaleFollow-Up StudiesHumansLinear ModelsMaleMiddle AgedRecurrenceStentsSurvival RateTreatment OutcomeUnited StatesUnited States Food and Drug AdministrationConceptsElective stent placementBalloon angioplastyCoronary arteryStent placementElective stent implantationJohnson Interventional SystemsPostprocedural lumen diameterPrimary end pointEvent-free survivalClinical event ratesSmall coronary arteriesQuantitative coronary angiographyPalmaz-Schatz stentsAngioplasty groupAngiographic characteristicsCoronary angiographyClinical outcomesNew lesionsProcedural successDiameter stenosisStent groupStent implantationAbrupt closurePatientsAngioplasty
1997
Acute and Long-Term Outcome After Palmaz-Schatz Stenting: Analysis From the New Approaches To Coronary Intervention (NACI) Registry
Carrozza J, Schatz R, George C, Leon M, King S, Hirshfeld J, Curry R, Ivanhoe R, Buchbinder M, Cleman M, Goldberg S, Ricci D, Popma J, Safian R, Baim D, Investigators F. Acute and Long-Term Outcome After Palmaz-Schatz Stenting: Analysis From the New Approaches To Coronary Intervention (NACI) Registry. The American Journal Of Cardiology 1997, 80: 78k-88k. PMID: 9409695, DOI: 10.1016/s0002-9149(97)00767-4.Peer-Reviewed Original ResearchConceptsPalmaz-Schatz stentsStent Restenosis StudyTarget lesion revascularizationCoronary Intervention RegistryRecent myocardial infarctionMinimum lumen diameterMyocardial infarctionLesion revascularizationIntervention RegistryProcedural successCoronary arteryHigh riskHigh incidenceLumen diameterSignificant left main stenosisLeft main coronary arteryQ-wave myocardial infarctionPalmaz-Schatz stentingDe novo lesionsLeft main stenosisSaphenous vein graftsCohort of patientsCongestive heart failureMain coronary arteryNative coronary arteries
1994
Long-term angiographic and clinical outcome after implantation of a ballon-expandable stent in the native coronary circulation
Savage M, Fischman D, Schatz R, Teirstein P, Leon M, Baim D, Ellis S, Topol E, Hirshfeld J, Cleman M, Buchbinder M, Bailey S, Heuser R, Walker C, Curry R, Gebhardt S, Rake R, Goldberg S, group F. Long-term angiographic and clinical outcome after implantation of a ballon-expandable stent in the native coronary circulation. Journal Of The American College Of Cardiology 1994, 24: 1207-1212. PMID: 7930240, DOI: 10.1016/0735-1097(94)90099-x.Peer-Reviewed Original ResearchConceptsNative coronary circulationAdverse clinical eventsMinimal lumen diameterClinical eventsUntreated lesionsStent implantationLumen diameterRepeat angioplastyClinical outcomesCoronary arteryCoronary circulationMyocardial infarctionEvent-free survival rateFinal minimal lumen diameterSingle Palmaz-Schatz stentsSubsequent adverse clinical eventsInitial angiographic resultsCoronary bypass surgeryNative coronary arteriesCoronary stent implantationFavorable clinical outcomeFollow-up angiographyLower restenosis rateEdge detection programPalmaz-Schatz stents
1991
Clinical experience with the Palmaz-Schatz coronary stent. Initial results of a multicenter study.
Schatz R, Baim D, Leon M, Ellis S, Goldberg S, Hirshfeld J, Cleman M, Cabin H, Walker C, Stagg J. Clinical experience with the Palmaz-Schatz coronary stent. Initial results of a multicenter study. Circulation 1991, 83: 148-161. PMID: 1984878, DOI: 10.1161/01.cir.83.1.148.Peer-Reviewed Original ResearchConceptsUrgent bypass surgeryBypass surgeryPerioperative complicationsMyocardial infarctionGroup 2Group 1Palmaz-Schatz coronary stentSuccessful elective coronary angioplastyUnderwent cardiac catheterizationElective coronary angioplastyNative coronary arteriesAbsence of symptomsBalloon-expandable stentsClinical thrombosisPerioperative deathsElective angioplastyCardiac catheterizationCoronary angioplastyMajor complicationsMulticenter studyCoronary arteryPatient populationLower incidencePatientsAbrupt closure