2023
Simulation results for limited-angle ultra-high time-of-flight resolution PET system
Marin T, Zhuo Y, Orehar M, Razdevšekc G, Dolenec R, Mounime I, Alamo J, Benlloch J, Chemli Y, Fernández-Tenllado J, Gascon D, Gola A, Gomez S, Grogg K, Guberman D, Korpar S, Krizan P, Majewski S, Manera R, Mariscal-Castilla A, Mauricio J, Merzi S, Morera C, Normandin M, Pavon G, Penna M, Seljak A, Studen A, Pestotnik R, Fakhri G. Simulation results for limited-angle ultra-high time-of-flight resolution PET system. 2023, 00: 1-1. DOI: 10.1109/nssmicrtsd49126.2023.10337821.Peer-Reviewed Original ResearchResolution PET systemsPET systemAxial fieldPositron emission tomography systemPositron emission tomography scannerTotal-body PET systemsLong axial fieldTOF resolutionNovel detectorNumerical phantomHigh-sensitivity systemMonte-Carlo simulationsSpatial resolutionPositron emission tomographyMonte-CarloSystem sensitivityImage resolutionImage qualityScintillationReconstruction engineFWHMResolutionTOFPhantomScannerImaging Performance of the Fully Assembled Ultra-High Resolution (UHR) Brain PET scanner
Loignon-Houle F, Toussaint M, Beaudoin J, Gaudreault M, Doyon V, Leroux J, Auger E, Thibaudeau C, Arpin L, Croteau E, Espinosa-Bentancourt E, Samson A, Bouchard J, Espagnet R, Viscogliosi N, Pepin C, Labrecque V, Paulin C, Marin T, Ouyang J, Normandin M, Tétrault M, Michaud J, Fontaine R, Fakhri G, Lecomte R. Imaging Performance of the Fully Assembled Ultra-High Resolution (UHR) Brain PET scanner. 2023, 00: 1-1. DOI: 10.1109/nssmicrtsd49126.2023.10338146.Peer-Reviewed Original ResearchBrain PET scannerUltra-high resolutionPET scannerPeak noise-equivalent count rateUltra Micro Hot Spot PhantomNoise-equivalent count rateAxial field-of-viewHot spot phantomHoffman brain phantomSmall-scale structuresCount rateBrain phantomContrast recoveryReadout schemeField of viewBrain PET imagingPhantomExcellent image qualityImaging performanceSpatial resolutionSmall structuresUltrahigh resolutionImage qualityPET imagingLarger rodsImpact of motion correction on [18F]-MK6240 tau PET imaging
Tiss A, Marin T, Chemli Y, Spangler-Bickell M, Gong K, Lois C, Petibon Y, Landes V, Grogg K, Normandin M, Becker A, Thibault E, Johnson K, Fakhri G, Ouyang J. Impact of motion correction on [18F]-MK6240 tau PET imaging. Physics In Medicine And Biology 2023, 68: 105015. PMID: 37116511, PMCID: PMC10278956, DOI: 10.1088/1361-6560/acd161.Peer-Reviewed Original ResearchConceptsMotion correctionPET quantitationImpact of motion correctionList-mode reconstructionMotion correction methodList-mode dataMotion-corrected imagesEffect of motion correctionVoxel displacementsPhantom experimentsOptical tracking dataLong acquisitionBrain PET scansSlow motionImage qualityPET imagingPositron emission tomographyCorrectionMotionCorrection methodRates of tau accumulationHead motionMotion metricsPhantomPositron
2016
Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR
Petibon Y, Guehl N, Reese T, Ebrahimi B, Normandin M, Shoup T, Alpert N, Fakhri G, Ouyang J. Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR. Physics In Medicine And Biology 2016, 62: 326-343. PMID: 27997375, PMCID: PMC5241952, DOI: 10.1088/1361-6560/aa5087.Peer-Reviewed Original ResearchConceptsSimultaneous PET-MRPET myocardial perfusion imagingMyocardial perfusion imagingPoint spread functionPoint-spread function correctionUngated dataMotion correctionPET-MRPartial volume effectsApparent wall thicknessMyocardial blood flowPartial volume effect correctionMR-based motion correctionMotion fieldPET-MR scannersPoint spread function modelPET dataPerfusion imagingImage qualityImpact of motionDynamic myocardial perfusion imagingAttenuation mapNon-rigid registrationAbsolute myocardial blood flowUngated images
2015
National Electrical Manufacturers Association and Clinical Evaluation of a Novel Brain PET/CT Scanner
Grogg K, Toole T, Ouyang J, Zhu X, Normandin M, Li Q, Johnson K, Alpert N, Fakhri G. National Electrical Manufacturers Association and Clinical Evaluation of a Novel Brain PET/CT Scanner. Journal Of Nuclear Medicine 2015, 57: 646-652. PMID: 26697961, PMCID: PMC4818715, DOI: 10.2967/jnumed.115.159723.Peer-Reviewed Original ResearchConceptsNoise-equivalent count rateCount rateLoose cutsMaximum noise-equivalent counting rateSpatial resolutionDetector ringSilicon photomultipliersBrain phantomContrast recoveryAttenuation correctionPET/CT systemCrystal blockPET/CT scannerImage qualityRadial offsetNational Electrical Manufacturers AssociationActivity distributionUnique mobility capabilitiesAxial extentTransverse resolutionPhantomAxial resolutionActivity concentrationsHuman scansLayer 1 cm