2021
Impact of reconstruction parameters on lesion detection and localization in joint ictal/inter-ictal SPECT reconstruction
Onwanna J, Chantadisai M, Tepmongkol S, Fahey F, Ouyang J, Rakvongthai Y. Impact of reconstruction parameters on lesion detection and localization in joint ictal/inter-ictal SPECT reconstruction. Annals Of Nuclear Medicine 2021, 36: 24-32. PMID: 34559366, DOI: 10.1007/s12149-021-01680-x.Peer-Reviewed Original ResearchConceptsLocalization receiver operating characteristicsDetection performanceSubtraction methodJoint methodOptimization iterationsLesion detection performanceSPECT reconstructionEpileptic focus localizationLocalization receiver operating characteristic curvesDifferential imagingInter-ictalLesion detectionIterationPhantom dataConventional subtraction methodPerformanceImagesPatient datasetsReconstruction parametersImpact of reconstruction parametersFocus localizationSubtractionDetectionSPECT dataJoint reconstruction
2014
Relative role of motion and PSF compensation in whole‐body oncologic PET‐MR imaging
Petibon Y, Huang C, Ouyang J, Reese T, Li Q, Syrkina A, Chen Y, Fakhri G. Relative role of motion and PSF compensation in whole‐body oncologic PET‐MR imaging. Medical Physics 2014, 41: 042503. PMID: 24694156, PMCID: PMC3971824, DOI: 10.1118/1.4868458.Peer-Reviewed Original ResearchConceptsPoint spread function modelRespiratory motionPoint spread functionPET-MR scannersPencil-beam navigator echoesPET-MRMeasurement of respiratory motionPSF modelRespiratory motion correctionDetector blur effectsModel respiratory motionLung-liver interfacePatient studiesLesion contrastSimultaneous PET-MRSource of image degradationWhole-body PET imagingPET reconstruction algorithmMoving lesionsPhantom experiment resultsPET eventsContrast recoveryNavigator echoesIterative reconstruction processMotion correctionMyocardial Defect Detection Using PET-CT: Phantom Studies
Mananga E, Fakhri G, Schaefferkoetter J, Bonab A, Ouyang J. Myocardial Defect Detection Using PET-CT: Phantom Studies. PLOS ONE 2014, 9: e88200. PMID: 24505429, PMCID: PMC3914931, DOI: 10.1371/journal.pone.0088200.Peer-Reviewed Original ResearchConceptsMyocardial defect detectionFiltered back projectionChannelized Hotelling observerPhantom studyActivity distributionSubset expectation maximizationDefect detectionCardiac PET studiesMyocardial defectsHotelling observerNoise levelBack-projectionPET-CTPhantomExpectation maximizationOP-OSEMReconstruction schemePET studiesOSEMDefectsNoise
2011
Monitoring proton radiation therapy with in-room PET imaging
Zhu X, España S, Daartz J, Liebsch N, Ouyang J, Paganetti H, Bortfeld T, Fakhri G. Monitoring proton radiation therapy with in-room PET imaging. Physics In Medicine And Biology 2011, 56: 4041-4057. PMID: 21677366, PMCID: PMC3141290, DOI: 10.1088/0031-9155/56/13/019.Peer-Reviewed Original ResearchConceptsIn-room positron emission tomographyIn-roomProton therapy treatment roomPositron emission tomography systemProton range verificationSoft tissue-equivalent materialMonte Carlo predictionsTissue-equivalent materialsPositron emission tomography acquisition timesProton radiation therapyPositron emission tomographyBiological washoutRange verificationProton therapyList-modeActivity distribution patternsPhantom studyTreatment roomPET acquisitionSoft tissue regionsIn vivo verificationDeep-siteOff-line modalityPositron emission tomography dataAdenoid cystic carcinoma