2020
Stent selection among patients with chronic kidney disease: Results from the NCDR CathPCI Registry
Feldman DA, Shroff AR, Bao H, Curtis JP, Minges KE, Ardati AK. Stent selection among patients with chronic kidney disease: Results from the NCDR CathPCI Registry. Catheterization And Cardiovascular Interventions 2020, 96: 1213-1221. PMID: 31909543, DOI: 10.1002/ccd.28698.Peer-Reviewed Original ResearchConceptsChronic kidney diseasePercutaneous coronary interventionST-elevation myocardial infarctionDES usageBare metal stentsNCDR CathPCI RegistryCathPCI RegistryRenal functionKidney diseasePCI casesElective percutaneous coronary interventionAdvanced renal dysfunctionNormal renal functionCoronary stent placementCKD stageRenal dysfunctionCoronary interventionUse of DESMyocardial infarctionStent placementSubgroup analysisStent usageMetal stentsPatientsStent selection
2016
Association Between a Prolonged PR Interval and Outcomes of Cardiac Resynchronization Therapy
Friedman DJ, Bao H, Spatz ES, Curtis JP, Daubert JP, Al-Khatib SM. Association Between a Prolonged PR Interval and Outcomes of Cardiac Resynchronization Therapy. Circulation 2016, 134: 1617-1628. PMID: 27760795, PMCID: PMC5418126, DOI: 10.1161/circulationaha.116.022913.Peer-Reviewed Original ResearchConceptsHeart failure hospitalizationFailure hospitalizationPR intervalImplantable cardioverter defibrillatorNational Cardiovascular Data Registry ICD RegistryCardiac resynchronization therapy candidatesIncident heart failure hospitalizationReal-world comparative effectivenessCRT-eligible patientsReceipt of CRTChronic kidney diseaseCardiac resynchronization therapyCRT-D patientsCoronary artery diseaseProlonged PR intervalComparative effectiveness analysisMore comorbiditiesArtery diseaseDiabetes mellitusICD recipientsICD RegistryResynchronization therapyAtrial arrhythmiasKidney diseaseCardioverter defibrillator
2015
Comparative Effectiveness of CRT-D Versus Defibrillator Alone in HF Patients With Moderate-to-Severe Chronic Kidney Disease
Friedman DJ, Singh JP, Curtis JP, Tang WHW, Bao H, Spatz ES, Hernandez AF, Patel UD, Al-Khatib SM. Comparative Effectiveness of CRT-D Versus Defibrillator Alone in HF Patients With Moderate-to-Severe Chronic Kidney Disease. Journal Of The American College Of Cardiology 2015, 66: 2618-2629. PMID: 26670062, DOI: 10.1016/j.jacc.2015.09.097.Peer-Reviewed Original ResearchMeSH KeywordsAgedAged, 80 and overCardiac Resynchronization TherapyComorbidityComparative Effectiveness ResearchDefibrillators, ImplantableElectric CountershockFemaleGlomerular Filtration RateHeart FailureHospitalizationHumansMaleMedicareProportional Hazards ModelsRenal Insufficiency, ChronicSeverity of Illness IndexSurvival AnalysisTreatment OutcomeUnited StatesConceptsSevere chronic kidney diseaseChronic kidney diseaseCardiac resynchronization therapyCRT-eligible patientsHF hospitalizationKidney diseaseNational Cardiovascular Data Registry ICD RegistryUse of CRTComparative effectivenessInverse probability-weighted analysisReal-world comparative effectivenessEnd-stage renal diseaseCox proportional hazards modelCRT-D useHeart failure hospitalizationAcceptable complication rateDevice-related complicationsProportional hazards modelFine-Gray modelCKD classCKD stageFailure hospitalizationHF patientsPrimary endpointSecondary endpoints
2014
Survival After Primary Prevention Implantable Cardioverter-Defibrillator Placement Among Patients With Chronic Kidney Disease
Hess PL, Hellkamp AS, Peterson ED, Sanders GD, Al-Khalidi HR, Curtis LH, Hammill BG, Pun PH, Curtis JP, Anstrom KJ, Hammill SC, Al-Khatib SM. Survival After Primary Prevention Implantable Cardioverter-Defibrillator Placement Among Patients With Chronic Kidney Disease. Circulation Arrhythmia And Electrophysiology 2014, 7: 793-799. PMID: 25038119, PMCID: PMC4206571, DOI: 10.1161/circep.114.001455.Peer-Reviewed Original ResearchMeSH KeywordsAgedCause of DeathChi-Square DistributionComorbidityDeath, Sudden, CardiacDefibrillators, ImplantableElectric CountershockFemaleGlomerular Filtration RateHeart FailureHumansKaplan-Meier EstimateKidneyLinear ModelsMaleMiddle AgedMultivariate AnalysisPatient SelectionPrimary PreventionProportional Hazards ModelsProsthesis DesignRegistriesRenal Insufficiency, ChronicRisk AssessmentRisk FactorsSeverity of Illness IndexTime FactorsTreatment OutcomeUnited StatesConceptsChronic kidney diseasePrimary prevention ICD placementRisk of deathICD placementCKD severityKidney diseaseNational Cardiovascular Data Registry ICD RegistryPrimary prevention implantable cardioverter-defibrillator placementGlomerular filtration rate 30Implantable cardioverter-defibrillator candidatesEnd-stage renal diseaseImplantable cardioverter-defibrillator placementSocial Security Death Master FileHeart failure symptomsLow ejection fractionGlomerular filtration rateRate of deathDeath Master FileICD candidacyCKD stageDiabetes mellitusEjection fractionICD RegistryRenal diseaseSerum sodium
2008
Distal Embolic Protection During Renal Artery Stenting: Impact on Hypertensive Patients With Renal Dysfunction
Singer GM, Setaro JF, Curtis JP, Remetz MS. Distal Embolic Protection During Renal Artery Stenting: Impact on Hypertensive Patients With Renal Dysfunction. Journal Of Clinical Hypertension 2008, 10: 830-836. PMID: 19128271, PMCID: PMC8672993, DOI: 10.1111/j.1751-7176.2008.00030.x.Peer-Reviewed Original ResearchConceptsDistal embolic protectionChronic kidney diseaseBlood pressureRenal arteryHypertensive patientsEmbolic protectionDEP patientsRenal artery stentingSystolic BP reductionGlomerular filtration rateSystolic blood pressureBP reductionEGFR improvementRenal dysfunctionArtery stentingKidney diseaseFiltration rateAtherosclerotic debrisPatientsArteryMonthsEGFRBaselineHypertensionEmbolization