2024
Design Optimisation of a Flat-Panel, Limited-Angle TOF-PET Scanner: A Simulation Study
Orehar M, Dolenec R, Fakhri G, Korpar S, Križan P, Razdevšek G, Marin T, Žontar D, Pestotnik R. Design Optimisation of a Flat-Panel, Limited-Angle TOF-PET Scanner: A Simulation Study. Diagnostics 2024, 14: 1976. PMID: 39272760, DOI: 10.3390/diagnostics14171976.Peer-Reviewed Original ResearchTime-of-flight positron emission tomographyTOF-PET scannerNEMA NU 2Evaluate spatial resolutionPET detectorsNU 2Scintillation materialsBiograph VisionRing scannerLimited-angleScanner designReadout levelsPoint sourcesFlat panel geometryClinical scannerSpatial resolutionReadout strategySingle-crystalImage qualityScintillationScannerFlat panelDesign parametersDetectorDesign optimisation
2023
Simulation results for limited-angle ultra-high time-of-flight resolution PET system
Marin T, Zhuo Y, Orehar M, Razdevšekc G, Dolenec R, Mounime I, Alamo J, Benlloch J, Chemli Y, Fernández-Tenllado J, Gascon D, Gola A, Gomez S, Grogg K, Guberman D, Korpar S, Krizan P, Majewski S, Manera R, Mariscal-Castilla A, Mauricio J, Merzi S, Morera C, Normandin M, Pavon G, Penna M, Seljak A, Studen A, Pestotnik R, Fakhri G. Simulation results for limited-angle ultra-high time-of-flight resolution PET system. 2023, 00: 1-1. DOI: 10.1109/nssmicrtsd49126.2023.10337821.Peer-Reviewed Original ResearchResolution PET systemsPET systemAxial fieldPositron emission tomography systemPositron emission tomography scannerTotal-body PET systemsLong axial fieldTOF resolutionNovel detectorNumerical phantomHigh-sensitivity systemMonte-Carlo simulationsSpatial resolutionPositron emission tomographyMonte-CarloSystem sensitivityImage resolutionImage qualityScintillationReconstruction engineFWHMResolutionTOFPhantomScanner
2022
Optimization of Design Parameters of Flat Panel Limited Angle TOF-PET Scanner: a Simulation Study
Orehar M, Dolenec R, Fakhri G, Gascón D, Gola A, Korpar S, Križan P, Razdevšek G, Pestotnik R. Optimization of Design Parameters of Flat Panel Limited Angle TOF-PET Scanner: a Simulation Study. 2022, 00: 1-4. DOI: 10.1109/nss/mic44845.2022.10399330.Peer-Reviewed Original ResearchImage quality phantomFlat-panel detectorGATE softwareRing scannerPanel detectorDetection chainState-of-the-artNEMA standardsOpen geometryImage reconstructionReconstructed imagesPositron emission tomographyState-of-the-art scannersScannerPhantomDetectorPhotodetectorsElectronNEMAMaterial costGatePositron
2003
A Multi-Scanner Evaluation of PET Image Quality Using Phantom Studies
Surti S, Badawi R, Holdsworth C, Fakhri G, Kinahan P, Karp J. A Multi-Scanner Evaluation of PET Image Quality Using Phantom Studies. 2003, 4: 2425-2427. DOI: 10.1109/nssmic.2003.1352384.Peer-Reviewed Original ResearchSignal-to-noise ratioImage signal-to-noisePET image qualityImage signal-to-noise ratioDiameter phantomImage qualityPhantom diameterPET scannerNEC ratesPhantom studyMeasures of image qualitySignal-to-noisePhantomAcquisition modeFilter observerSpecific tasksAccurate measurementRate dropsSinogramScannerPreliminary resultsECAT