2024
Design Optimisation of a Flat-Panel, Limited-Angle TOF-PET Scanner: A Simulation Study
Orehar M, Dolenec R, Fakhri G, Korpar S, Križan P, Razdevšek G, Marin T, Žontar D, Pestotnik R. Design Optimisation of a Flat-Panel, Limited-Angle TOF-PET Scanner: A Simulation Study. Diagnostics 2024, 14: 1976. PMID: 39272760, PMCID: PMC11487429, DOI: 10.3390/diagnostics14171976.Peer-Reviewed Original ResearchTime-of-flight positron emission tomographyTOF-PET scannerNEMA NU 2Evaluate spatial resolutionPET detectorsNU 2Scintillation materialsBiograph VisionRing scannerLimited-angleScanner designReadout levelsPoint sourcesFlat panel geometryClinical scannerSpatial resolutionReadout strategySingle-crystalImage qualityScintillationScannerFlat panelDesign parametersDetectorDesign optimisation
2019
Performance evaluation of the 5‐Ring GE Discovery MI PET/CT system using the national electrical manufacturers association NU 2‐2012 Standard
Pan T, Einstein S, Kappadath S, Grogg K, Gomez C, Alessio A, Hunter W, Fakhri G, Kinahan P, Mawlawi O. Performance evaluation of the 5‐Ring GE Discovery MI PET/CT system using the national electrical manufacturers association NU 2‐2012 Standard. Medical Physics 2019, 46: 3025-3033. PMID: 31069816, PMCID: PMC7251507, DOI: 10.1002/mp.13576.Peer-Reviewed Original ResearchConceptsAxial field-of-viewPeak noise-equivalent count rateNoise-equivalent count rateField of viewCount ratePET performanceNational Electrical Manufacturers Association NU-2Transaxial field of viewPET/CT systemTime resolutionMean energy resolutionConventional photomultiplier tubesCount rate performanceImage quality phantomSpatial resolution measurementsFiltered back projection algorithmImage qualityEnergy resolutionAcquisition timeNU 2Count lossDetector designPhotomultiplier tubeMean energyPET/MR systems
2008
Realistic PET Monte Carlo Simulation with Pixelated Block Detectors, Light Sharing, Random Coincidences and Dead-Time Modeling
Guérin B, Fakhri G. Realistic PET Monte Carlo Simulation with Pixelated Block Detectors, Light Sharing, Random Coincidences and Dead-Time Modeling. IEEE Transactions On Nuclear Science 2008, 55: 942-952. PMID: 19079776, PMCID: PMC2600659, DOI: 10.1109/tns.2008.924064.Peer-Reviewed Original ResearchBlock detectorsDiscovery STRandom coincidencesSimSET softwareMonte Carlo transport codeElectronics dead-timeNEMA NU 2Detector dead-timeDead-timeMonte Carlo simulation softwarePositron emission tomography scannerSimulated spatial resolutionPET modelingSpatial resolutionWhole scannerCoincidence spectraPhoton interactionsEnergy spectrumNU 2Light sharingTransport codeSingles ratesCrystal elementsDead-time modelMonte Carlo simulations
2005
Realistic Monte Carlo PET Simulation with Pixellated Block Detectors, Light Sharing and Randoms Modeling
Guérin B, Fakhri G. Realistic Monte Carlo PET Simulation with Pixellated Block Detectors, Light Sharing and Randoms Modeling. 2005, 3: 1563-1567. DOI: 10.1109/nssmic.2005.1596617.Peer-Reviewed Original ResearchPET scannerBlock detectorsPhoton transportRandom coincidencesSimSET softwareMonte Carlo transport codeNEMA NU 2Model of photon transportEnergy weighted averageModel photon transportLight-sharingEnergy spectrumNU 2Light sharingTransport codeCrystal elementsMonte Carlo simulationsPET simulationsVery good agreementInteraction pointPET acquisitionDetection crystalAttenuation distributionDetectorCarlo simulations