2014
Towards coronary plaque imaging using simultaneous PET-MR: a simulation study
Petibon Y, Fakhri G, Nezafat R, Johnson N, Brady T, Ouyang J. Towards coronary plaque imaging using simultaneous PET-MR: a simulation study. Physics In Medicine And Biology 2014, 59: 1203-1222. PMID: 24556608, PMCID: PMC4061607, DOI: 10.1088/0031-9155/59/5/1203.Peer-Reviewed Original ResearchMeSH KeywordsComputer SimulationCoronary AngiographyCoronary StenosisHumansImage Interpretation, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance AngiographyModels, CardiovascularMultimodal ImagingPhantoms, ImagingPositron-Emission TomographyReproducibility of ResultsSensitivity and SpecificityConceptsSimultaneous PET-MRChannelized Hotelling observerAttenuation mapMotion correctionPET-MRFluorodeoxyglucose-positron emission tomography imagingRespiratory motion fieldsMotion correction methodCho SNRMotion correction techniqueAnthropomorphic phantomUncorrected reconstructionsRespiratory motionXCAT phantomCoronary plaque imagingMonte Carlo simulationsPET reconstructionXCATActivity distributionCardiac gatingNon-rigid registrationHotelling observerCarlo simulationsPlaque imagingPhantom
2007
Impact of Acquisition Geometry, Image Processing, and Patient Size on Lesion Detection in Whole-Body 18F-FDG PET
Fakhri G, Santos P, Badawi R, Holdsworth C, Van Den Abbeele A, Kijewski M. Impact of Acquisition Geometry, Image Processing, and Patient Size on Lesion Detection in Whole-Body 18F-FDG PET. Journal Of Nuclear Medicine 2007, 48: 1951-1960. PMID: 18006613, DOI: 10.2967/jnumed.108.007369.Peer-Reviewed Original ResearchConceptsAttenuation-weighted OSEMOrdered-subset expectation maximizationNoise equivalent countPhantom sizeBed positionCho SNRPatient sizeFourier rebinningAttenuation mapPET scannerLesion detectionMarginal detectionTransmission scanWhole-body (18)F-FDG PETAttenuation correctionWhole-body 18F-FDG PETHotelling observerScaling 2DSinogramReconstructed volumeDetection SNRPhantomSystematic improvementFBPScattering
2006
Optimizing Acquisition Parameters in TOF PET Scanners
Surti S, El-Fakhri G, Karp J. Optimizing Acquisition Parameters in TOF PET Scanners. 2006, 4: 2354-2359. DOI: 10.1109/nssmic.2006.354386.Peer-Reviewed Original ResearchNoise equivalent countCho SNRNon-TOF scannerScan timePET image qualityPatient dosageTime-of-flightSingles ratesOptimal acquisition parametersPET scannerTOF scannerDiameter cylinderIncreasing scan timeImage qualityReduce scan timeMeasure of signal-to-noise ratioSignal-to-noise ratioSpatial resolutionSNRAcquisition parametersLesion detectionLesionsTOFCylinderIncreased activity