Featured Publications
Central vein sign: A diagnostic biomarker in multiple sclerosis (CAVS-MS) study protocol for a prospective multicenter trial
Ontaneda D, Sati P, Raza P, Kilbane M, Gombos E, Alvarez E, Azevedo C, Calabresi P, Cohen JA, Freeman L, Henry RG, Longbrake EE, Mitra N, Illenberger N, Schindler M, Moreno-Dominguez D, Ramos M, Mowry E, Oh J, Rodrigues P, Chahin S, Kaisey M, Waubant E, Cutter G, Shinohara R, Reich DS, Solomon A, Sicotte NL, Cooperative N. Central vein sign: A diagnostic biomarker in multiple sclerosis (CAVS-MS) study protocol for a prospective multicenter trial. NeuroImage Clinical 2021, 32: 102834. PMID: 34592690, PMCID: PMC8482479, DOI: 10.1016/j.nicl.2021.102834.Peer-Reviewed Original ResearchConceptsCentral vein signDiagnosis of MSMultiple sclerosisDiagnostic biomarkersMcDonald criteriaVein signProspective multicenter trialCross-sectional studyNumerous cross-sectional studiesNorth American ImagingNeuroradiologist reviewMulticenter trialAtypical presentationMulticenter studyTypical presentationSectional studyStudy protocolClinical careMS lesionsCentral readersEcho-planar MRIDiagnostic criteriaMS misdiagnosisMRI biomarkersMajor cause
2024
Incorporation of the Central Vein Sign into the McDonald Criteria
Amin M, Nakamura K, Daboul L, O'Donnell C, Cao Q, Rodrigues P, Derbyshire J, Azevedo C, Bar-Or A, Caverzasi E, Calabresi P, Cree B, Freeman L, Henry R, Longbrake E, Oh J, Papinutto N, Pelletier D, Prčkovska V, Raza P, Ramos M, Samudralwar R, Schindler M, Sotirchos E, Sicotte N, Solomon A, Shinohara R, Reich D, Sati P, Ontaneda D. Incorporation of the Central Vein Sign into the McDonald Criteria. Multiple Sclerosis And Related Disorders 2024, 106182. DOI: 10.1016/j.msard.2024.106182.Peer-Reviewed Original ResearchCentral vein signDIS criteriaDiagnostic performanceMultiple sclerosisDeep white matter lesionsDiagnosis of multiple sclerosisMulti-center studyInternational multi-center studyWhite matter lesionsNorth American ImagingMcDonald CriteriaProspective studyDiagnostic accuracyMRI disseminationDemyelinating diseaseBackground DiagnosisMS diagnosisDiagnostic biomarkersCompare sensitivityLesionsBrain locationsMethods DataBrain imagingBrainSignsMulticenter automated central vein sign detection performs as well as manual assessment for the diagnosis of multiple sclerosis.
Manning A, Letchuman V, Martin M, Gombos E, Roberts-Fitzgerald T, Cao Q, Raza P, O'Donnell C, Renner B, Daboul L, Rodrigues P, Ramos M, Derbyshire J, Azevedo C, Bar-Or A, Caverzasi E, Calabresi P, Cree B, Freeman L, Henry R, Longbrake E, Oh J, Papinutto N, Pelletier D, Samudralwar R, Suthiphosuwan S, Schindler M, Bilello M, Song J, Sotirchos E, Sicotte N, Al-Louzi O, Solomon A, Reich D, Ontaneda D, Sati P, Shinohara R. Multicenter automated central vein sign detection performs as well as manual assessment for the diagnosis of multiple sclerosis. American Journal Of Neuroradiology 2024 PMID: 39332906, DOI: 10.3174/ajnr.a8510.Peer-Reviewed Original ResearchCentral vein signCVS+ lesionsWhite matter lesionsMultiple sclerosisMulticenter studyProportions of white matter lesionsSuspicion of MSReceiver-operating characteristic curveFluid-attenuated inversion recoveryDiagnosis of multiple sclerosisDiagnosis of MSMagnetic resonance imagingAtypical clinical syndromeRadiological mimicsClinical syndromeDiagnostic imaging biomarkersManual assessmentT MRIClinical implementationImaging biomarkersLesionsInversion recoveryResonance imagingCharacteristic curveInter-rater reliabilityDiagnostic performance of central vein sign versus oligoclonal bands for multiple sclerosis
Toljan K, Daboul L, Raza P, Martin M, Cao Q, O’Donnell C, Rodrigues P, Derbyshire J, Azevedo C, Bar-Or A, Caverzasi E, Calabresi P, Cree B, Freeman L, Henry R, Longbrake E, Oh J, Papinutto N, Pelletier D, Samudralwar R, Schindler M, Sotirchos E, Sicotte N, Solomon A, Shinohara R, Reich D, Sati P, Ontaneda D. Diagnostic performance of central vein sign versus oligoclonal bands for multiple sclerosis. Multiple Sclerosis Journal 2024, 30: 1268-1277. PMID: 39234802, PMCID: PMC11421977, DOI: 10.1177/13524585241271988.Peer-Reviewed Original ResearchConceptsCentral vein signPositive predictive valueOligoclonal bandsDiagnostic performanceMS diagnosisCerebrospinal fluidMultiple sclerosisPredictive valueNegative predictive valueCerebrospinal fluid testingRadiological suspicionDiagnostic accuracyImaging biomarkersDiagnosisDiagnostic biomarkersMonthsSclerosisBiomarkersPilot studyBaselineSelection 3
2023
A multicenter pilot study evaluating simplified central vein assessment for the diagnosis of multiple sclerosis
Daboul L, O’Donnell C, Amin M, Rodrigues P, Derbyshire J, Azevedo C, Bar-Or A, Caverzasi E, Calabresi P, Cree B, Freeman L, Henry R, Longbrake E, Oh J, Papinutto N, Pelletier D, Prchkovska V, Raza P, Ramos M, Samudralwar R, Schindler M, Sotirchos E, Sicotte N, Solomon A, Shinohara R, Reich D, Sati P, Ontaneda D. A multicenter pilot study evaluating simplified central vein assessment for the diagnosis of multiple sclerosis. Multiple Sclerosis Journal 2023, 30: 25-34. PMID: 38088067, PMCID: PMC11037932, DOI: 10.1177/13524585231214360.Peer-Reviewed Original ResearchConceptsCentral vein signMultiple sclerosisPositive lesionsInter-rater agreementDiagnosis of MSMagnetic resonance imaging (MRI) biomarkersDiagnostic performancePossible multiple sclerosisInter-rater reliability assessmentGood diagnostic performanceMcDonald criteriaMulticenter studyVein assessmentMean ageVein signImaging biomarkersLesionsMRI sequencesCharacteristic curveSclerosisPatientsDiagnosisAssessmentParticipantsOptimal method
2022
Effect of GBCA Use on Detection and Diagnostic Performance of the Central Vein Sign: Evaluation Using a 3-T FLAIR* Sequence in Patients With Suspected Multiple Sclerosis.
Daboul L, O'Donnell CM, Cao Q, Amin M, Rodrigues P, Derbyshire J, Azevedo C, Bar-Or A, Caverzasi E, Calabresi P, Cree BAC, Freeman L, Henry RG, Longbrake EE, Nakamura K, Oh J, Papinutto N, Pelletier D, Samudralwar RD, Suthiphosuwan S, Schindler MK, Sotirchos ES, Sicotte NL, Solomon AJ, Shinohara RT, Reich DS, Ontaneda D, Sati P. Effect of GBCA Use on Detection and Diagnostic Performance of the Central Vein Sign: Evaluation Using a 3-T FLAIR* Sequence in Patients With Suspected Multiple Sclerosis. American Journal Of Roentgenology 2022, 220: 115-125. PMID: 35975888, PMCID: PMC10016223, DOI: 10.2214/ajr.22.27731.Peer-Reviewed Original ResearchConceptsWhite matter lesionsCentral vein signGBCA useMultiple sclerosisMS diagnosisVein signPostcontrast imagesGadolinium-based contrast agent administrationPilot study cohortDiagnostic performanceContrast agent administrationMcDonald criteriaInvestigational trialsStudy cohortMatter lesionsClinical dataClinical impactBrain MRIClinical practiceAgent administrationDiagnostic biomarkersMRI biomarkersPostcontrast FLAIRPrecontrast imagesSecondary analysis