2021
MDPET: A Unified Motion Correction and Denoising Adversarial Network for Low-Dose Gated PET
Zhou B, Tsai YJ, Chen X, Duncan JS, Liu C. MDPET: A Unified Motion Correction and Denoising Adversarial Network for Low-Dose Gated PET. IEEE Transactions On Medical Imaging 2021, 40: 3154-3164. PMID: 33909561, PMCID: PMC8588635, DOI: 10.1109/tmi.2021.3076191.Peer-Reviewed Original ResearchConceptsMotion estimationPyramid networkAdversarial networkAccurate motion estimationMotion correctionLow-noise reconstructionGated positron emission tomographyMotion correction methodMotion estimation networkGated PET dataEstimation networkRecurrent layersDenoising NetworkRespiratory motion blurringExperimental resultsLow-noise imagesMotion blurringNoise levelCorrection methodNetworkPET reconstructionPrevious methodsImage qualityImagesEstimation
2020
Simultaneous Denoising and Motion Estimation for Low-Dose Gated PET Using a Siamese Adversarial Network with Gate-to-Gate Consistency Learning
Zhou B, Tsai Y, Liu C. Simultaneous Denoising and Motion Estimation for Low-Dose Gated PET Using a Siamese Adversarial Network with Gate-to-Gate Consistency Learning. Lecture Notes In Computer Science 2020, 12267: 743-752. DOI: 10.1007/978-3-030-59728-3_72.Peer-Reviewed Original ResearchMotion estimationMotion estimation networkRobust motion estimationMotion correction methodRespiratory motion blurringEstimation networkNoise ratioMotion correctionMotion blurringImage volumesCorrection methodCorrection stepMotion vectorsGateSimultaneous denoisingImage qualityEstimationAdversarial network
2015
Scatter and crosstalk corrections for 99mTc/123I dual‐radionuclide imaging using a CZT SPECT system with pinhole collimators
Fan P, Hutton BF, Holstensson M, Ljungberg M, Pretorius P, Prasad R, Ma T, Liu Y, Wang S, Thorn SL, Stacy MR, Sinusas AJ, Liu C. Scatter and crosstalk corrections for 99mTc/123I dual‐radionuclide imaging using a CZT SPECT system with pinhole collimators. Medical Physics 2015, 42: 6895-6911. PMID: 26632046, DOI: 10.1118/1.4934830.Peer-Reviewed Original ResearchConceptsDual-radionuclide imagingCrosstalk correction methodTEW methodLine source experimentDefect contrastSource experimentsMonte Carlo simulationsIncomplete charge collectionCadmium zinc telluride detectorsLow-energy tailImaging systemCarlo simulationsPinhole collimatorCardiac SPECT systemEnergy tailDetector effectsEnergy spectrumPoint source measurementsSPECT systemCZT detectorsTriple energy window (TEW) methodScatter modelDedicated cardiac SPECT systemsCorrection methodCrosstalk correction