2024
PET motion correction using subspace-based real-time MR imaging in simultaneous PET/MR
Mounime I, Marin T, Han P, Ouyang J, Gori P, Angelini E, Fakhri G, Ma C. PET motion correction using subspace-based real-time MR imaging in simultaneous PET/MR. 2024, 00: 1-1. DOI: 10.1109/nss/mic/rtsd57108.2024.10657647.Peer-Reviewed Original ResearchOrdered-subset expectation maximizationMotion correctionGated reconstructionsMotion-corrected PET reconstructionsPET eventsCardiac motion phasesMotion correction methodCardiac motionMotion phaseReconstructed dynamic imagesPET reconstructionReal-time MR imagingSimultaneous PET/MRPatient motionSoft tissue contrastDynamic MR image reconstructionReference phaseMitigate artifactsLow-rank propertyMR image reconstructionPositron emission tomographyManifold learning frameworkSpatial resolutionBlurring artifactsImage reconstruction
2021
Quantification of Myocardial Mitochondrial Membrane Potential Using PET
Pelletier-Galarneau M, Detmer F, Petibon Y, Normandin M, Ma C, Alpert N, El Fakhri G. Quantification of Myocardial Mitochondrial Membrane Potential Using PET. Current Cardiology Reports 2021, 23: 70. PMID: 33970353, PMCID: PMC8443083, DOI: 10.1007/s11886-021-01500-8.Peer-Reviewed Original Research
2020
MR‐based PET attenuation correction using a combined ultrashort echo time/multi‐echo Dixon acquisition
Han P, Horng D, Gong K, Petibon Y, Kim K, Li Q, Johnson K, Fakhri G, Ouyang J, Ma C. MR‐based PET attenuation correction using a combined ultrashort echo time/multi‐echo Dixon acquisition. Medical Physics 2020, 47: 3064-3077. PMID: 32279317, PMCID: PMC7375929, DOI: 10.1002/mp.14180.Peer-Reviewed Original ResearchConceptsLinear attenuation coefficientPositron emission tomography attenuation correctionPhysical compartmental modelAttenuation correctionShort T<sub>2</sub> componentPET attenuation correctionRadial k-space trajectoryMagnetic resonance (MR)-based methodK-space trajectoriesRadial trajectoryK-spaceAttenuation coefficientDixon acquisitionsPositron emission tomographyWhole white matterMuting methodImage reconstructionImaging speedMR signalMRAC methodPositron emission tomography imagingCorrectionGray matter regionsPhantomMatter regions
2019
Body motion detection and correction in cardiac PET: Phantom and human studies
Sun T, Petibon Y, Han P, Ma C, Kim S, Alpert N, Fakhri G, Ouyang J. Body motion detection and correction in cardiac PET: Phantom and human studies. Medical Physics 2019, 46: 4898-4906. PMID: 31508827, PMCID: PMC6842053, DOI: 10.1002/mp.13815.Peer-Reviewed Original ResearchConceptsList-mode dataMotion-compensated image reconstructionMotion correctionCenter of massPET list-mode dataMotion correction methodMotion detectionMotion estimationImage reconstructionPatient body motionDegrade image qualityNonrigid registrationImage qualityMotion transformationCoincident distributionBody motion detectionCardiac positron emission tomographyBack-projection techniqueCovariance matrixImage volumesBody motionPositron emission tomographyBack-projectionReference framePhantom