2023
Colchicine and high-intensity rosuvastatin in the treatment of non-critically ill patients hospitalised with COVID-19: a randomised clinical trial
Shah T, McCarthy M, Nasir I, Archer H, Ragheb E, Kluger J, Kashyap N, Paredes C, Patel P, Lu J, Kandel P, Song C, Khan M, Huang H, Haq F, Ahmad R, Howes C, Cambi B, Lancaster G, Cleman M, Dela Cruz C, Parise H, Lansky A. Colchicine and high-intensity rosuvastatin in the treatment of non-critically ill patients hospitalised with COVID-19: a randomised clinical trial. BMJ Open 2023, 13: e067910. PMID: 36828654, PMCID: PMC9971831, DOI: 10.1136/bmjopen-2022-067910.Peer-Reviewed Original ResearchMeSH KeywordsBrain IschemiaColchicineCOVID-19FemaleHumansMaleMiddle AgedRosuvastatin CalciumSARS-CoV-2StrokeTreatment OutcomeConceptsStandard of careHigh-intensity rosuvastatinElectronic medical recordsCOVID-19 diseaseMedical recordsPrimary endpointThromboembolic eventsYale New Haven Health SystemSevere COVID-19 diseaseCOVID-19Prespecified primary endpointVenous thromboembolic eventsRisk of progressionCombination of colchicineSafety monitoring boardCare armHispanics/LatinosTherapeutic anticoagulationIndex hospitalisationIll patientsMedian ageFuture trialsEffect of colchicineClinical trialsMonitoring board
2020
Cerebral Embolic Protection Burden of Proof ∗
Lansky A, Pietras C, Shah T. Cerebral Embolic Protection Burden of Proof ∗. JACC Cardiovascular Interventions 2020, 13: 2156-2158. PMID: 32972579, DOI: 10.1016/j.jcin.2020.06.030.Peer-Reviewed Original Research
2016
Neurologic Complications of Unprotected Transcatheter Aortic Valve Implantation (from the Neuro-TAVI Trial)
Lansky AJ, Brown D, Pena C, Pietras CG, Parise H, Ng VG, Meller S, Abrams KJ, Cleman M, Margolis P, Petrossian G, Brickman AM, Voros S, Moses J, Forrest JK. Neurologic Complications of Unprotected Transcatheter Aortic Valve Implantation (from the Neuro-TAVI Trial). The American Journal Of Cardiology 2016, 118: 1519-1526. PMID: 27645761, DOI: 10.1016/j.amjcard.2016.08.013.Peer-Reviewed Original ResearchMeSH KeywordsAged, 80 and overAortic ValveAortic Valve StenosisBrainBrain IschemiaDiffusion Magnetic Resonance ImagingFemaleFollow-Up StudiesHumansIncidenceIntracranial EmbolismMalePostoperative ComplicationsPrognosisProspective StudiesRisk AssessmentRisk FactorsSurvival RateTranscatheter Aortic Valve ReplacementUnited StatesConceptsTranscatheter aortic valve implantationAortic valve implantationNeurologic injuryValve implantationNeurologic impairmentMagnetic resonance imaging lesionsCognitive AssessmentMontreal Cognitive Assessment scoreCerebral ischemic lesionsNew neurologic impairmentSubclinical cerebral infarctsDiffusion-weighted magnetic resonance imagingTotal lesion volumeCognitive Assessment scoreMontreal Cognitive AssessmentMagnetic resonance imagingCerebral embolizationCerebral infarctsNeurologic complicationsCerebral infarctionImaging lesionsMost patientsOvert strokeConsecutive patientsIschemic lesions
2015
Safety and performance of a novel embolic deflection device in patients undergoing transcatheter aortic valve replacement: results from the DEFLECT I study.
Baumbach A, Mullen M, Brickman AM, Aggarwal SK, Pietras CG, Forrest JK, Hildick-Smith D, Meller SM, Gambone L, den Heijer P, Margolis P, Voros S, Lansky AJ. Safety and performance of a novel embolic deflection device in patients undergoing transcatheter aortic valve replacement: results from the DEFLECT I study. EuroIntervention 2015, 11: 75-84. PMID: 25868876, DOI: 10.4244/eijy15m04_01.Peer-Reviewed Original ResearchMeSH KeywordsAgedAged, 80 and overAlloysAortic ValveAortic Valve StenosisBrain IschemiaBrazilCardiac CatheterizationCognitionCognition DisordersDiffusion Magnetic Resonance ImagingEmbolic Protection DevicesEuropeFemaleHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHumansIntracranial EmbolismMalePredictive Value of TestsProspective StudiesProsthesis DesignRisk FactorsSeverity of Illness IndexStrokeTime FactorsTreatment OutcomeUltrasonography, Doppler, TranscranialConceptsTranscatheter aortic valve replacementAortic valve replacementValve replacementNew cerebral ischemic lesionsCerebral diffusion-weighted magnetic resonance imagingCerebral ischemic lesionsDays post procedurePrimary safety endpointDiffusion-weighted magnetic resonance imagingMajor cerebral arteriesTotal lesion volumeMagnetic resonance imagingSafety endpointIschemic lesionsTAVR proceduresCerebral arteryCerebral circulationConsecutive subjectsPost procedureAortic archHistorical controlsLesion volumeResonance imagingDW-MRIPatients