2011
Impact of Lesion Length and Vessel Size on Clinical Outcomes After Percutaneous Coronary Intervention With Everolimus- Versus Paclitaxel-Eluting Stents Pooled Analysis From the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice) Randomized Trials
Claessen BE, Smits PC, Kereiakes DJ, Parise H, Fahy M, Kedhi E, Serruys PW, Lansky AJ, Cristea E, Sudhir K, Sood P, Simonton CA, Stone GW. Impact of Lesion Length and Vessel Size on Clinical Outcomes After Percutaneous Coronary Intervention With Everolimus- Versus Paclitaxel-Eluting Stents Pooled Analysis From the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice) Randomized Trials. JACC Cardiovascular Interventions 2011, 4: 1209-1215. PMID: 22115661, DOI: 10.1016/j.jcin.2011.07.016.Peer-Reviewed Original ResearchMeSH KeywordsAgedAngioplasty, Balloon, CoronaryCardiovascular AgentsChi-Square DistributionCoronary AngiographyCoronary StenosisDrug-Eluting StentsEverolimusFemaleHumansKaplan-Meier EstimateMaleMiddle AgedMyocardial InfarctionPaclitaxelPredictive Value of TestsProportional Hazards ModelsProsthesis DesignRandomized Controlled Trials as TopicRisk AssessmentRisk FactorsSeverity of Illness IndexSirolimusThrombosisTime FactorsTreatment OutcomeConceptsMajor adverse cardiac eventsPaclitaxel-eluting stentsReference vessel diameterEverolimus-eluting stentsPercutaneous coronary interventionLong lesionsGroup BLesion lengthMACE rateCoronary interventionSmall vesselsGroup AStent typeShort lesionsAdverse cardiac eventsHigh-risk patientsPatient-level dataLarge vesselsLower ratesCOMPARE trialLesion revascularizationEfficacy outcomesAdverse eventsCardiac eventsIndependent predictors
2003
Optimal final lumen area and predictors of target lesion revascularization after stent implantation in small coronary arteries
Iakovou I, Mintz GS, Dangas G, Abizaid A, Mehran R, Lansky AJ, Kobayashi Y, Hirose M, Ashby DT, Stone GW, Moses JW, Leon MB. Optimal final lumen area and predictors of target lesion revascularization after stent implantation in small coronary arteries. The American Journal Of Cardiology 2003, 92: 1171-1176. PMID: 14609591, DOI: 10.1016/j.amjcard.2003.07.025.Peer-Reviewed Original ResearchConceptsTarget lesion revascularizationGreater stent expansionSmall coronary arteriesCoronary arteryLesion revascularizationTLR rateStent implantationStent areaSmall vesselsPredictors of TLRAngiographic reference vessel diameterGroup IStent expansionLumen areaHigher TLR rateGroup II patientsBaseline patient characteristicsReference vessel diameterPrior myocardial infarctionEarly clinical eventsReference vessel areaFinal lumen areaHospital outcomesClinical restenosisPatient characteristics
2002
Coronary heart disease stenting in small vessels versus balloon angloplasty study (CHIVAS): a randomized prospective multicenter trial
Muramatsu T, Iwasaki K, Inoue N, Horita Y, Tanaka T, Fujita N, Kamiya H, Namura M, Awano K, Murakami M, Ozaki Y, Lansky A. Coronary heart disease stenting in small vessels versus balloon angloplasty study (CHIVAS): a randomized prospective multicenter trial. Journal Of The American College Of Cardiology 2002, 39: 50. DOI: 10.1016/s0735-1097(02)80217-0.Peer-Reviewed Original Research
2000
Relation of coronary artery size to one-year clinical events after new device angioplasty of native coronary arteries (a New Approach to Coronary Intervention [NACI] Registry report)
Saucedo J, Popma J, Kennard E, Talley J, Lansky A, Leon M, Baim D, Investigators F. Relation of coronary artery size to one-year clinical events after new device angioplasty of native coronary arteries (a New Approach to Coronary Intervention [NACI] Registry report). The American Journal Of Cardiology 2000, 85: 166-171. PMID: 10955371, DOI: 10.1016/s0002-9149(99)00649-9.Peer-Reviewed Original ResearchConceptsReference vessel diameterNew device angioplastyNative coronary arteriesMinimal lumen diameterClinical eventsAngiographic outcomesCoronary arteryFinal minimal lumen diameterFinal percent diameter stenosisMajor adverse clinical eventsOne-year clinical eventsSmaller reference vessel diameterBaseline lesion characteristicsRisk of TLRCombined end pointAdverse clinical eventsCoronary artery diseaseCoronary Intervention RegistryEarly clinical eventsIncidence of deathSmall vesselsCoronary artery sizePercent diameter stenosisLesion revascularizationMultivessel disease
1996
Contemporary stent designs: Technical considerations, complications, role of intravascular ultrasound, and anticoagulation therapy
Popma J, Lansky A, Ito S, Mintz G, Leon M. Contemporary stent designs: Technical considerations, complications, role of intravascular ultrasound, and anticoagulation therapy. Progress In Cardiovascular Diseases 1996, 39: 111-128. PMID: 8841006, DOI: 10.1016/s0033-0620(96)80021-1.Peer-Reviewed Original ResearchConceptsBalloon angioplastyIntravascular ultrasoundSaphenous vein graft diseaseClinical useLate clinical benefitNative coronary arteriesVein graft diseaseStent designCurrent antiplateletAnticoagulation therapyAntithrombotic therapyGraft diseaseAdjunct therapyClinical benefitCoronary arteryStent placementDiffuse diseaseStent useBifurcation stenosisTherapySmall vesselsAngioplastyComplicationsNumber of studiesDisease