2022
Sex-Specific Outcomes After Coronary Intravascular Lithotripsy: A Patient-Level Analysis of the Disrupt CAD Studies
Hussain Y, Kearney K, Abbott J, Kereiakes D, Di Mario C, Saito S, Cristea E, Riley R, Fajadet J, Shlofmitz R, Ali Z, Klein A, Price M, Hill J, Stone G, Lansky A. Sex-Specific Outcomes After Coronary Intravascular Lithotripsy: A Patient-Level Analysis of the Disrupt CAD Studies. Journal Of The Society For Cardiovascular Angiography & Interventions 2022, 1: 100011. PMID: 39130137, PMCID: PMC11307712, DOI: 10.1016/j.jscai.2021.100011.Peer-Reviewed Original ResearchPrimary efficacy end pointPrimary safety end pointMajor adverse cardiovascular eventsAdverse cardiovascular eventsEfficacy end pointSafety end pointIntravascular lithotripsyEnd pointCardiovascular eventsMyocardial infarctionHospital major adverse cardiovascular eventsMean reference vessel diameterCoronary intravascular lithotripsySevere coronary calcificationCoronary artery calcificationReference vessel diameterPercutaneous coronary interventionPrior myocardial infarctionSex-based outcomesSex-specific outcomesSide branch involvementPatient-level analysisSmall vessel sizeAngiographic complicationsLesion predilatation
2021
TCT-122 Sex-Specific Characteristics and Outcomes in Coronary Intravascular Lithotripsy: A Patient-Level Analysis of the Disrupt CAD Studies
Hussain Y, Kereiakes D, Di Mario C, Saito S, Kearney K, Abbott J, Cristea E, Lansky A. TCT-122 Sex-Specific Characteristics and Outcomes in Coronary Intravascular Lithotripsy: A Patient-Level Analysis of the Disrupt CAD Studies. Journal Of The American College Of Cardiology 2021, 78: b51-b52. DOI: 10.1016/j.jacc.2021.09.972.Peer-Reviewed Original Research
2020
Safety and effectiveness of coronary intravascular lithotripsy in eccentric calcified coronary lesions: a patient-level pooled analysis from the Disrupt CAD I and CAD II Studies
Blachutzik F, Honton B, Escaned J, Hill JM, Werner N, Banning AP, Lansky AJ, Schlattner S, De Bruyne B, Di Mario C, Dörr O, Hamm C, Nef HM. Safety and effectiveness of coronary intravascular lithotripsy in eccentric calcified coronary lesions: a patient-level pooled analysis from the Disrupt CAD I and CAD II Studies. Clinical Research In Cardiology 2020, 110: 228-236. PMID: 32948882, PMCID: PMC7862504, DOI: 10.1007/s00392-020-01737-3.Peer-Reviewed Original ResearchConceptsCoronary intravascular lithotripsyIntravascular lithotripsyCalcified coronary lesionsII studyResidual stenosisCoronary lesionsCAD IPooled patient-level analysisFinal residual stenosisPercent residual stenosisFlow-limiting dissectionPatient-level analysisPatient-level dataHospital MACEIVL useAcute gainClinical outcomesConcentric lesionsEccentric lesionsCalcified lesionsAbrupt closureReflow eventsResultsClinical successStenosisConcentric stenosis
2015
Safety and efficacy of a novel abluminal groove‐filled biodegradable polymer sirolimus‐eluting stent for the treatment of de novo coronary lesions: Two‐year results from a prospective patient‐level pooled analysis of TARGET trials
Gao Z, Zhang R, Xu B, Yang Y, Ma C, Li H, Chen S, Han Y, Yuan Z, Lansky AJ, Guan C, Leon MB, Gao R, Investigators F. Safety and efficacy of a novel abluminal groove‐filled biodegradable polymer sirolimus‐eluting stent for the treatment of de novo coronary lesions: Two‐year results from a prospective patient‐level pooled analysis of TARGET trials. Catheterization And Cardiovascular Interventions 2015, 85: 734-743. PMID: 25678281, DOI: 10.1002/ccd.25861.Peer-Reviewed Original ResearchMeSH KeywordsAbsorbable ImplantsAgedCardiovascular AgentsChinaCoronary Artery DiseaseDrug-Eluting StentsFemaleHumansKaplan-Meier EstimateMaleMiddle AgedMyocardial InfarctionPercutaneous Coronary InterventionPolymersProspective StudiesProsthesis DesignRandomized Controlled Trials as TopicRegistriesRisk FactorsSirolimusTime FactorsTreatment OutcomeConceptsTarget lesion failureFIREHAWK stentStent thrombosisCoronary lesionsMyocardial infarctionNovel abluminal groove-filled biodegradable polymer sirolimus-eluting stentDe novo native coronary lesionsBiodegradable polymer sirolimus-eluting stentsDe novo coronary lesionsPatient-level pooled analysisTarget vessel myocardial infarctionNew drug-eluting stentsNative coronary lesionsNovo coronary lesionsProbable stent thrombosisTarget lesion revascularizationVessel myocardial infarctionSirolimus-eluting stentsPatient-level analysisPatient-level dataLong-term safetyDrug-eluting stentsTwo-year resultsObjective performance criteriaLesion revascularization