2020
First-in-Human Evaluation of 18F-SynVesT-1, a Radioligand for PET Imaging of Synaptic Vesicle Glycoprotein 2A
Naganawa M, Li S, Nabulsi N, Henry S, Zheng MQ, Pracitto R, Cai Z, Gao H, Kapinos M, Labaree D, Matuskey D, Huang Y, Carson RE. First-in-Human Evaluation of 18F-SynVesT-1, a Radioligand for PET Imaging of Synaptic Vesicle Glycoprotein 2A. Journal Of Nuclear Medicine 2020, 62: 561-567. PMID: 32859701, PMCID: PMC8049363, DOI: 10.2967/jnumed.120.249144.Peer-Reviewed Original ResearchConceptsC-UCBSynaptic densityRegional time-activity curvesTime-activity curvesDistribution volumeMetabolite-corrected arterial input functionPET imagingMultilinear analysis 1Synaptic vesicle glycoprotein 2AAntiepileptic drug levetiracetamTotal distribution volumeNondisplaceable distribution volumeCentrum semiovaleBlocking doseHealthy volunteersHuman studiesDrug levetiracetamLassen plotNeuropsychiatric disordersPET radioligandArterial input functionNonhuman primatesLevetiracetamReference regionRadioligand
2019
Development and In Vivo Evaluation of a κ-Opioid Receptor Agonist as a PET Radiotracer with Superior Imaging Characteristics
Li S, Zheng MQ, Naganawa M, Kim S, Gao H, Kapinos M, Labaree D, Huang Y. Development and In Vivo Evaluation of a κ-Opioid Receptor Agonist as a PET Radiotracer with Superior Imaging Characteristics. Journal Of Nuclear Medicine 2019, 60: 1023-1030. PMID: 30630942, PMCID: PMC6604690, DOI: 10.2967/jnumed.118.220517.Peer-Reviewed Original ResearchConceptsMultilinear analysis 1Κ-opioid receptor agonistCentral nervous system diseaseNervous system diseasesHigh specific bindingAgonist tracersGlobus pallidusReceptor abnormalitiesReceptor agonistFrontal cortexSystem diseasesPrimate brainReceptor occupancySuperior imaging characteristicsCingulate cortexAlzheimer's diseasePeak uptakeImaging characteristicsRhesus monkeysOptimal radiotracerPET studiesArterial input functionBlocking studiesPET radiotracersAnalysis 1
2017
PET Imaging Evaluation of Four σ1 Radiotracers in Nonhuman Primates
Baum E, Cai Z, Bois F, Holden D, Lin SF, Lara-Jaime T, Kapinos M, Chen Y, Deuther-Conrad W, Fischer S, Dukic-Stefanovic S, Bunse P, Wünsch B, Brust P, Jia H, Huang Y. PET Imaging Evaluation of Four σ1 Radiotracers in Nonhuman Primates. Journal Of Nuclear Medicine 2017, 58: 982-988. PMID: 28232607, DOI: 10.2967/jnumed.116.188052.Peer-Reviewed Original ResearchConceptsImaging evaluationHigh specific binding signalsRhesus monkeysFast tissue kineticsAdult male rhesus monkeysHigh brain uptakeMale rhesus monkeysBrain uptakeDistribution volume valuesBaseline scanRhesus brainVariety of diseasesSpecific binding signalsTime-activity curvesCingulate cortexAlzheimer's diseaseBrain regionsDistribution volumeRadiotracer bindingArterial input functionPET radiotracersPET tracersNonhuman primatesSame monkeysTissue kinetics
2015
Test–Retest Reproducibility of Binding Parameters in Humans with 11C-LY2795050, an Antagonist PET Radiotracer for the κ Opioid Receptor
Naganawa M, Zheng MQ, Henry S, Nabulsi N, Lin SF, Ropchan J, Labaree D, Najafzadeh S, Kapinos M, Tauscher J, Neumeister A, Carson RE, Huang Y. Test–Retest Reproducibility of Binding Parameters in Humans with 11C-LY2795050, an Antagonist PET Radiotracer for the κ Opioid Receptor. Journal Of Nuclear Medicine 2015, 56: 243-248. PMID: 25593119, PMCID: PMC4322754, DOI: 10.2967/jnumed.114.147975.Peer-Reviewed Original ResearchConceptsTest-retest variabilityOpioid receptorsOutcome measuresAbsolute test-retest variabilityMultilinear analysis 1Healthy human subjectsSuitable reference regionTest-retest reproducibilityIntraclass correlation coefficientAntagonist radiotracersHealthy subjectsLY2795050PET scansBrain regionsDistribution volumePET radioligandTest-retest performancePET studiesArterial input functionPET radiotracersHuman subjectsReference regionReceptorsVT valuesKOR