2023
Performance and reliability assessment of a lower dose, task-based scoliosis radiography protocol in pediatric patients
Al-Dasuqi K, Taylor E, Ehrlich L, Cooperman D, Socci A, Tuason D, Hoerner M, Staib L, Silva C. Performance and reliability assessment of a lower dose, task-based scoliosis radiography protocol in pediatric patients. Pediatric Radiology 2023, 54: 146-153. PMID: 38010426, DOI: 10.1007/s00247-023-05812-5.Peer-Reviewed Original ResearchMeSH KeywordsChildFemaleHumansImaging, Three-DimensionalMaleRadiographyReproducibility of ResultsRetrospective StudiesScoliosisConceptsDose area productPatient heightAdequate image qualityEffective doseExposure indexMedian effective doseLower radiation exposureComparison of proportionsChi-squared testIntraclass correlation coefficientBland-Altman plotsConsecutive patientsPediatric patientsIncident air kermaDose reductionLow doseSkeletal maturityRadiographsPatientsAir kermaRadiation exposureScoliosis radiographyStatistical significanceDoseSpinal curvature
2019
Reevaluation of FAST Sensitivity in Pediatric Blunt Abdominal Trauma Patients
Riera A, Hayward H, Silva C, Chen L. Reevaluation of FAST Sensitivity in Pediatric Blunt Abdominal Trauma Patients. Pediatric Emergency Care 2019, 37: e1012-e1019. PMID: 31356479, DOI: 10.1097/pec.0000000000001877.Peer-Reviewed Original ResearchMeSH KeywordsAbdominal InjuriesChildFemaleHemoperitoneumHumansMaleReproducibility of ResultsRetrospective StudiesSensitivity and SpecificityUltrasonographyWounds, NonpenetratingConceptsBlunt abdominal trauma patientsAbdominal trauma patientsFree fluidTrauma patientsUpper quadrantPredictive valueLevel I pediatric trauma centerPediatric trauma centerRetrospective chart reviewRight upper quadrantFAST examinationNegative predictive valuePositive predictive valueNegative likelihood ratioChart reviewBAT patientsMedian ageTrauma centerUpper abdomenIntraperitoneal fluidMAIN OUTCOMEPhysiologic amountsTrauma (FAST) examinationPatientsFocused assessment
2017
Inter-rater reliability of physical abuse determinations in young children with fractures
Buesser KE, Leventhal JM, Gaither JR, Tate V, Cooperman DR, Moles RL, Silva CT, Ehrlich LJ, Sharkey MS. Inter-rater reliability of physical abuse determinations in young children with fractures. Child Abuse & Neglect 2017, 72: 140-146. PMID: 28802910, DOI: 10.1016/j.chiabu.2017.08.001.Peer-Reviewed Original ResearchConceptsChild abuse pediatriciansModerate agreementPediatric emergency departmentMedical record dataYoung childrenAbusive injuriesEmergency departmentJoint ratingsClinical detailsInter-rater reliabilityPediatric radiologistsClinical scenariosMedical providersPairs of ratersPediatric orthopaedistsLevel of agreementOrthopaedistsRecord dataCliniciansGold standardIndependent ratingsRadiologistsChildrenExtent of agreementPhysicians
2015
Diagnostic accuracy of point-of-care ultrasound for catheter-related thrombosis in children
Li S, Silva CT, Brudnicki AR, Baker KE, Tala JA, Pinto MG, Polikoff LA, Qin L, Faustino EV, Northeast Pediatric Critical Care Research Consortium. Diagnostic accuracy of point-of-care ultrasound for catheter-related thrombosis in children. Pediatric Radiology 2015, 46: 219-228. PMID: 26440129, PMCID: PMC4738063, DOI: 10.1007/s00247-015-3467-9.Peer-Reviewed Original ResearchMeSH KeywordsAge DistributionCausalityCentral Venous CathetersChildChild, PreschoolCohort StudiesConnecticutFemaleHumansInfantInfant, NewbornMalePoint-of-Care TestingPrevalenceReproducibility of ResultsRisk FactorsSensitivity and SpecificitySex DistributionUltrasonographyUpper Extremity Deep Vein ThrombosisConceptsCatheter-related thrombosisCare ultrasoundChance-corrected agreementIll childrenCare USCentral venous catheter-related thrombosisPediatric radiologistsDeep venous thrombosisCentral venous cathetersIntensive care unitVenous cathetersVenous thrombosisCare unitSubclavian veinThrombosisAccuracy of pointCatheterSensitivity of pointDiscordant readingsDiagnostic accuracyMulticenterUltrasoundRadiology departmentChildrenPhysicians
2013
A prospective comparison of intestinal sonography and abdominal radiographs in a neonatal intensive care unit
Silva CT, Daneman A, Navarro OM, Moineddin R, Levine D, Moore AM. A prospective comparison of intestinal sonography and abdominal radiographs in a neonatal intensive care unit. Pediatric Radiology 2013, 43: 1453-1463. PMID: 24026851, DOI: 10.1007/s00247-013-2777-z.Peer-Reviewed Original ResearchConceptsIntestinal gas patternsSpectrum of appearancesAbdominal radiographsIntestinal pathologySonographic findingsFree fluidNeonatal intensive care unitIntensive care unitAbility of sonographyIntestinal wall thickeningGas patternIntestinal sonographyIntestinal dilatationCare unitGestational agePatient chartsIntensive careIntestinal loopsSonographic abnormalitiesBackgroundNo studyProspective comparisonIntestinal perfusionFluid collectionClinical informationEnterocolitis
2012
Early assessment of the efficacy of digital infrared thermal imaging in pediatric extremity trauma
Silva CT, Naveed N, Bokhari S, Baker KE, Staib LH, Ibrahim SM, Muchantef K, Goodman TR. Early assessment of the efficacy of digital infrared thermal imaging in pediatric extremity trauma. Emergency Radiology 2012, 19: 203-209. PMID: 22362422, DOI: 10.1007/s10140-012-1027-2.Peer-Reviewed Original ResearchConceptsPediatric extremity traumaExtremity traumaSite of painPediatric emergency departmentSite of injuryPain sitesEmergency departmentLimb traumaContralateral limbExtremity radiographsFracture sitePatientsFurther evaluationRadiographsTraumaSame dayEarly assessmentWhole limbIntellectual disabilityLocal hyperthermiaYoung childrenDITIEfficacyLimbFractures
2009
Computer-aided detection for the identification of pulmonary nodules in pediatric oncology patients: initial experience
Helm EJ, Silva CT, Roberts HC, Manson D, Seed MT, Amaral JG, Babyn PS. Computer-aided detection for the identification of pulmonary nodules in pediatric oncology patients: initial experience. Pediatric Radiology 2009, 39: 685-693. PMID: 19418048, DOI: 10.1007/s00247-009-1259-9.Peer-Reviewed Original ResearchMeSH KeywordsAdolescentAlgorithmsArtificial IntelligenceChildChild, PreschoolFemaleHumansLung NeoplasmsMaleObserver VariationPattern Recognition, AutomatedPilot ProjectsRadiographic Image EnhancementRadiographic Image Interpretation, Computer-AssistedReproducibility of ResultsSensitivity and SpecificitySolitary Pulmonary NoduleTomography, X-Ray ComputedConceptsPediatric oncology patientsPulmonary nodulesSensitivity of CADOncology patientsPediatric patientsPrimary tumorIRB approvalPediatric radiologistsMethodsCT scansInitial experiencePatientsLung nodulesNodule sizeNodulesAvailable CAD systemPerformance of CADRadiologistsComputer-aided detectionInitial findingsLow numberRadiologists' sensitivityObjectiveToTumorsSensitivity