Impact of reconstruction parameters on lesion detection and localization in joint ictal/inter-ictal SPECT reconstruction
Onwanna J, Chantadisai M, Tepmongkol S, Fahey F, Ouyang J, Rakvongthai Y. Impact of reconstruction parameters on lesion detection and localization in joint ictal/inter-ictal SPECT reconstruction. Annals Of Nuclear Medicine 2021, 36: 24-32. PMID: 34559366, DOI: 10.1007/s12149-021-01680-x.Peer-Reviewed Original ResearchConceptsLocalization receiver operating characteristicsDetection performanceSubtraction methodJoint methodOptimization iterationsLesion detection performanceSPECT reconstructionEpileptic focus localizationLocalization receiver operating characteristic curvesDifferential imagingInter-ictalLesion detectionIterationPhantom dataConventional subtraction methodPerformanceImagesPatient datasetsReconstruction parametersImpact of reconstruction parametersFocus localizationSubtractionDetectionSPECT dataJoint reconstruction
2014
MR‐based motion correction for PET imaging using wired active MR microcoils in simultaneous PET‐MR: Phantom study
Huang C, Ackerman J, Petibon Y, Brady T, Fakhri G, Ouyang J. MR‐based motion correction for PET imaging using wired active MR microcoils in simultaneous PET‐MR: Phantom study. Medical Physics 2014, 41: 041910. PMID: 24694141, PMCID: PMC3978416, DOI: 10.1118/1.4868457.Peer-Reviewed Original ResearchConceptsMotion correctionMR-based motion correctionStatic phantom dataPET quantitative accuracyPET-MRPET-MR scannersSimultaneous PET-MRHoffman phantomList-modePositron emission tomography imagingPET reconstructionBrain positron emission tomographyIterative PET reconstructionPhantom dataPhantomQuantitative accuracyIndependent noise realizationsImage contrastNoise realizationsHead motionPET dataPositron emission tomographyStatic referenceBrain PET scansMotion artifacts
2013
Simultaneous 99mTc‐MDP/123I‐MIBG tumor imaging using SPECT‐CT: Phantom and constructed patient studies
Rakvongthai Y, Fakhri G, Lim R, Bonab A, Ouyang J. Simultaneous 99mTc‐MDP/123I‐MIBG tumor imaging using SPECT‐CT: Phantom and constructed patient studies. Medical Physics 2013, 40: 102506. PMID: 24089927, PMCID: PMC3785531, DOI: 10.1118/1.4820977.Peer-Reviewed Original ResearchConceptsScatter correctionDual-radionuclideContrast recoveryPhantom studyAnthropomorphic torso phantomPatient studiesTumor uptakeTumor imagingSPECT projectionsTorso phantomMonte-CarloPhantom dataPhantomIterative reconstructionOSEMProjection dataDR dataIncrease patient throughputNoise realizationsSPECT-CTImage reconstructionClinical studiesTumorTumor projectionPoisson noise
2009
Quantitative simultaneous cardiac SPECT using MC‐JOSEM
Ouyang J, Zhu X, Trott C, Fakhri G. Quantitative simultaneous cardiac SPECT using MC‐JOSEM. Medical Physics 2009, 36: 602-611. PMID: 19292000, PMCID: PMC2673670, DOI: 10.1118/1.3063544.Peer-Reviewed Original ResearchConceptsMC-JOSEMEnergy windowWater-filled torso phantomScatter correctionPhotopeak energy windowStandard OSEMCardiac SPECT imagingActivity concentration ratioIterative reconstruction algorithmReconstruction algorithmMyocardium wallTorso phantomActivity estimationDetector responseEmission energyBackground compartmentPhantom dataCardiac SPECTActivity distributionRest/stress imagingScatteringCases of patientsOSEMChest painCardiac protocols