2018
Joint reconstruction of rest/stress myocardial perfusion SPECT
Lai X, Petibon Y, Fakhri G, Ouyang J. Joint reconstruction of rest/stress myocardial perfusion SPECT. Physics In Medicine And Biology 2018, 63: 135019. PMID: 29897044, PMCID: PMC6245543, DOI: 10.1088/1361-6560/aacc2f.Peer-Reviewed Original ResearchConceptsMyocardial perfusion imagingSingle photon emission computed tomographyReversible defectsSignal-to-noise ratioRest/stress SPECT myocardial perfusion imagingSPECT myocardial perfusion imagingConventional subtraction methodDefect detectionJoint methodPhoton emission computed tomographySubtraction methodReverse mappingClinical dose levelsEmission computed tomographyImprove defect detectionLow noiseNon-invasive assessmentClinical dosePerfusion defectsReduced doseImprove radiologists' performanceReconstruction frameworkRest imagesPerfusion imagingDose levels
2014
Effect of time‐of‐flight and point spread function modeling on detectability of myocardial defects in PET
Schaefferkoetter J, Ouyang J, Rakvongthai Y, Nappi C, El Fakhri G. Effect of time‐of‐flight and point spread function modeling on detectability of myocardial defects in PET. Medical Physics 2014, 41: 062502. PMID: 24877836, PMCID: PMC4032408, DOI: 10.1118/1.4875725.Peer-Reviewed Original ResearchConceptsSignal-to-noise ratioDetection signal-to-noise ratioPoint spread functionObserver signal-to-noise ratioEffects of time-of-flightMyocardial defectsHuman observer performanceDefect detectionSlow convergenceTime-of-flight (TOFNon-PSFPostreconstruction smoothingFDG-PET dataTime-of-flightPSF reconstructionCombination of TOFNon-TOFIterationObserver performanceClinical practiceSpread functionReconstruction parametersReconstruction protocolsIterative methodDetectionMyocardial Defect Detection Using PET-CT: Phantom Studies
Mananga E, Fakhri G, Schaefferkoetter J, Bonab A, Ouyang J. Myocardial Defect Detection Using PET-CT: Phantom Studies. PLOS ONE 2014, 9: e88200. PMID: 24505429, PMCID: PMC3914931, DOI: 10.1371/journal.pone.0088200.Peer-Reviewed Original ResearchConceptsMyocardial defect detectionFiltered back projectionChannelized Hotelling observerPhantom studyActivity distributionSubset expectation maximizationDefect detectionCardiac PET studiesMyocardial defectsHotelling observerNoise levelBack-projectionPET-CTPhantomExpectation maximizationOP-OSEMReconstruction schemePET studiesOSEMDefectsNoise
2013
Cardiac motion compensation and resolution modeling in simultaneous PET-MR: a cardiac lesion detection study
Petibon Y, Ouyang J, Zhu X, Huang C, Reese T, Chun S, Li Q, Fakhri G. Cardiac motion compensation and resolution modeling in simultaneous PET-MR: a cardiac lesion detection study. Physics In Medicine And Biology 2013, 58: 2085-2102. PMID: 23470288, PMCID: PMC3657754, DOI: 10.1088/0031-9155/58/7/2085.Peer-Reviewed Original ResearchConceptsContrast recoveryDetector point spread functionPartial volume effectsK-spaceMotion compensationB-spline registrationLesion-detection studiesCardiac motion compensationPET-MR scannersSimultaneous PET-MRPET contrastIterative reconstruction frameworkPoint spread functionMotion correctionPET countsNon-rigid B-spline registrationCardiac phantomPSF modelPET-MRMotion deblurringReconstruction frameworkSystem matrixCardiac PETSpread functionDefect detection