2022
A Comparison of Postprandial Glucose Control in the Medtronic Advanced Hybrid Closed-Loop System Versus 670G
Weinzimer S, Bailey RJ, Bergenstal RM, Nimri R, Beck RW, Schatz D, Ambler-Osborn L, Schweiger DS, von dem Berge T, Sibayan J, Johnson ML, Calhoun P, Phillip M, Bergenstal R, Phillip M, Criego A, Bergenstal R, Carlson A, Martens T, Beasley S, Johnson M, Whipple D, Hyatt J, Punel A, Grieme A, Thomas L, LaFrance A, Hasledalen C, Laffel L, Isganaitis E, Freiner E, Ambler-Osborn L, Desrochers H, Turcotte C, Naik N, Roethke L, Fisher M, Nimri R, Nevo M, Bello R, Hamou A, Hermon O, Horesh O, Shiovitch Mantzuri G, Drotz I, Yehiel N, Naveh R, Schatz D, Haller M, Albanese-O'Neill A, Sheehan E, Leey J, Smith M, Jacobsen L, Adams J, Hosford J, Whyte L, Battelino T, Dovč K, Bratina N, Šmigoc Schweiger D, Sever U, Gianini A, Murn Berkopec B, Mali B, Weinzimer S, Weyman K, Carria L, Zgorski M, Danne T, Biester T, von dem Berge T, Weiskorn J, Kordonouri O, Biester S, Aschemeier B, Remus K, Pisarek N, Sibayan J, Beck R, Mouse T, Davis J, Bailey R, Hellmann A, Reese N, Calhoun P, Strayer H, Cohen N, Henderson R, Kollman C, Kennedy J, Woodall W, Mahr I, Hood K, Arreaza-Rubin G, Eggerman T, Green N, Janicek R, Gabrielson D, Belle S, Castle J, Green J, Legault L, Willi S, Wysham C, Eggerman T. A Comparison of Postprandial Glucose Control in the Medtronic Advanced Hybrid Closed-Loop System Versus 670G. Diabetes Technology & Therapeutics 2022, 24: 573-582. PMID: 35363054, PMCID: PMC9353997, DOI: 10.1089/dia.2021.0568.Peer-Reviewed Original ResearchConceptsHybrid closed-loop systemGlucose levelsGlycemic controlGlycemic excursionsAdvanced hybrid closed-loop systemG armPostprandial glycemic excursionsPostprandial glycemic controlType 1 diabetesPostprandial glucose controlPrandial insulin deliveryTreatment armsCrossover trialGlucose controlMedtronic MiniMedSecondary analysisMeal sizeOvernight improvementInsulin deliveryHyperglycemiaOutcomesArmLevel 2HypoglycemiaPremeal
2021
A comparison of two hybrid closed-loop systems in adolescents and young adults with type 1 diabetes (FLAIR): a multicentre, randomised, crossover trial
Bergenstal RM, Nimri R, Beck RW, Criego A, Laffel L, Schatz D, Battelino T, Danne T, Weinzimer SA, Sibayan J, Johnson ML, Bailey RJ, Calhoun P, Carlson A, Isganaitis E, Bello R, Albanese-O'Neill A, Dovc K, Biester T, Weyman K, Hood K, Phillip M, Group F. A comparison of two hybrid closed-loop systems in adolescents and young adults with type 1 diabetes (FLAIR): a multicentre, randomised, crossover trial. The Lancet 2021, 397: 208-219. PMID: 33453783, PMCID: PMC9194961, DOI: 10.1016/s0140-6736(20)32514-9.Peer-Reviewed Original ResearchConceptsAdvanced hybrid closed-loop systemType 1 diabetesHybrid closed-loop systemMiniMed 670G systemGlucose levelsCrossover trialYoung adultsMultiple daily insulin injectionsSevere hypoglycaemic eventsDaily insulin injectionsComputer-generated sequencePermuted block designContinuous glucose monitoringBaseline HbACoprimary outcomesEndocrinology practiceHypoglycaemic eventsWashout periodHemoglobin levelsKidney diseaseMean ageInsulin injectionsProportion of timeContinuous glucose monitorImpaired awareness