2023
Detection of Intracerebral Hemorrhage Using Low-Field, Portable Magnetic Resonance Imaging in Patients With Stroke
Mazurek M, Parasuram N, Peng T, Beekman R, Yadlapalli V, Sorby-Adams A, Lalwani D, Zabinska J, Gilmore E, Petersen N, Falcone G, Sujijantarat N, Matouk C, Payabvash S, Sze G, Schiff S, Iglesias J, Rosen M, de Havenon A, Kimberly W, Sheth K. Detection of Intracerebral Hemorrhage Using Low-Field, Portable Magnetic Resonance Imaging in Patients With Stroke. Stroke 2023, 54: 2832-2841. PMID: 37795593, PMCID: PMC11103256, DOI: 10.1161/strokeaha.123.043146.Peer-Reviewed Original ResearchMeSH KeywordsCerebral HemorrhageHumansIschemic StrokeMagnetic Resonance ImagingStrokeTomography, X-Ray ComputedExpanding beyond ischemic stroke: A qualitative MRI score that facilitates outcome prediction in patients with hypoxic ischemic brain injury
Beekman R, Hirsch K. Expanding beyond ischemic stroke: A qualitative MRI score that facilitates outcome prediction in patients with hypoxic ischemic brain injury. Resuscitation 2023, 187: 109800. PMID: 37080336, DOI: 10.1016/j.resuscitation.2023.109800.Peer-Reviewed Original ResearchMeSH KeywordsBrainBrain InjuriesBrain IschemiaHumansHypoxia-Ischemia, BrainIschemic StrokeMagnetic Resonance ImagingPrognosisStrokeFuture of Neurology & Technology: Neuroimaging Made Accessible Using Low-Field, Portable MRI
Parasuram N, Crawford A, Mazurek M, Chavva I, Beekman R, Gilmore E, Petersen N, Payabvash S, Sze G, Eugenio Iglesias J, Omay S, Matouk C, Longbrake E, de Havenon A, Schiff S, Rosen M, Kimberly W, Sheth K. Future of Neurology & Technology: Neuroimaging Made Accessible Using Low-Field, Portable MRI. Neurology 2023, 100: 1067-1071. PMID: 36720639, PMCID: PMC10259275, DOI: 10.1212/wnl.0000000000207074.Peer-Reviewed Original Research
2022
Bedside monitoring of hypoxic ischemic brain injury using low-field, portable brain magnetic resonance imaging after cardiac arrest
Beekman R, Crawford A, Mazurek MH, Prabhat AM, Chavva IR, Parasuram N, Kim N, Kim JA, Petersen N, de Havenon A, Khosla A, Honiden S, Miller PE, Wira C, Daley J, Payabvash S, Greer DM, Gilmore EJ, Kimberly W, Sheth KN. Bedside monitoring of hypoxic ischemic brain injury using low-field, portable brain magnetic resonance imaging after cardiac arrest. Resuscitation 2022, 176: 150-158. PMID: 35562094, PMCID: PMC9746653, DOI: 10.1016/j.resuscitation.2022.05.002.Peer-Reviewed Original ResearchMeSH KeywordsBrainBrain InjuriesCritical IllnessFemaleHeart ArrestHumansHypoxia-Ischemia, BrainMagnetic Resonance ImagingMaleMiddle AgedRetrospective StudiesConceptsCardiac arrestBrain injuryHypoxic-ischemic brain injuryAdverse neurological outcomesIschemic brain injurySingle-center studyBrain magnetic resonanceBrain injury severityBoard-certified neuroradiologistsLow-field MRIFLAIR signal intensityNeurological outcomeCA patientsIll patientsMRI findingsCA survivorsCenter studyMRI examinationsClinical careHigh riskInjury severityPatientsSignal intensityBedside monitoringMR imaging
2021
Portable, bedside, low-field magnetic resonance imaging for evaluation of intracerebral hemorrhage
Mazurek MH, Cahn BA, Yuen MM, Prabhat AM, Chavva IR, Shah JT, Crawford AL, Welch EB, Rothberg J, Sacolick L, Poole M, Wira C, Matouk CC, Ward A, Timario N, Leasure A, Beekman R, Peng TJ, Witsch J, Antonios JP, Falcone GJ, Gobeske KT, Petersen N, Schindler J, Sansing L, Gilmore EJ, Hwang DY, Kim JA, Malhotra A, Sze G, Rosen MS, Kimberly WT, Sheth KN. Portable, bedside, low-field magnetic resonance imaging for evaluation of intracerebral hemorrhage. Nature Communications 2021, 12: 5119. PMID: 34433813, PMCID: PMC8387402, DOI: 10.1038/s41467-021-25441-6.Peer-Reviewed Original ResearchMeSH KeywordsAdultAgedAged, 80 and overBrainCerebral HemorrhageFemaleHumansMagnetic Resonance ImagingMaleMiddle AgedNeuroimagingConceptsMagnetic resonance imagingNIH Stroke ScaleIntracerebral hemorrhageHematoma volumeYale-New Haven HospitalStroke care pathwayConventional magnetic resonance imagingBoard-certified neuroradiologistsNew Haven HospitalResource-limited settingsStroke ScaleClinical outcomesLow-field magnetic resonance imagingCare pathwayLow-field magnetic resonanceRadiological examinationConventional neuroimagingAdvanced MRI technologiesResonance imagingCases of disagreementHemorrhageMRI technologyPortable MRINeuroimagingMagnetic resonance
2017
Clinical Reasoning
Beekman RB, Greer DM, Brooks DC, Maciel CB. Clinical Reasoning. Neurology 2017, 89: e239-e244. PMID: 29133614, DOI: 10.1212/wnl.0000000000004649.Peer-Reviewed Original Research