2024
Movable Linear Gradients Optimized on Non-Planar B0 Slice Profiles Used for Improving Spatial Encoding in a Non-Linear Low-Field MRI
Samardzija A, Ha Y, Sun C, Sun H, Gross R, Galiana G, Constable R. Movable Linear Gradients Optimized on Non-Planar B0 Slice Profiles Used for Improving Spatial Encoding in a Non-Linear Low-Field MRI. Proceedings Of The International Society For Magnetic Resonance In Medicine ... Scientific Meeting And Exhibition. 2024 DOI: 10.58530/2024/4076.Peer-Reviewed Original ResearchEncoding scheme design for gradient-free, nonlinear projection imaging using Bloch-Siegert RF spatial encoding in a low-field, open MRI system
Selvaganesan K, Ha Y, Sun H, Zhang Z, Sun C, Samardzija A, Galiana G, Constable R. Encoding scheme design for gradient-free, nonlinear projection imaging using Bloch-Siegert RF spatial encoding in a low-field, open MRI system. Scientific Reports 2024, 14: 3307. PMID: 38332252, PMCID: PMC10853509, DOI: 10.1038/s41598-024-53703-y.Peer-Reviewed Original ResearchConceptsBloch-SiegertSpatial encodingBloch-Siegert shiftGradient-freeLow-field imagesLow fieldsProjection imagesPhase shiftLoop coilEncoding settingsEncoding schemeEncoding trajectoriesLow-field MR imagingSpatial resolutionImage reconstructionOptimization algorithmEncodingMRI systemShift effectHardware setupMR systemOpen MRI systemScheme designAlgorithmImages
2023
Magnetic resonance imaging using a nonuniform Bo (NuBo) field-cycling magnet
Selvaganesan K, Wan Y, Ha Y, Wu B, Hancock K, Galiana G, Constable R. Magnetic resonance imaging using a nonuniform Bo (NuBo) field-cycling magnet. PLOS ONE 2023, 18: e0287344. PMID: 37319289, PMCID: PMC10270621, DOI: 10.1371/journal.pone.0287344.Peer-Reviewed Original ResearchConceptsInnovative data acquisitionMain magnetGradient coilsExperimental verificationEcho signalsInitial designField cyclingParallel imagingSuperior soft tissue contrastMagnetsInhomogeneous fieldsLow fieldsSoft tissue contrastReconstruction approachInhomogeneity effectsData acquisitionSpatial encodingPolarization phaseOpen MR systemPowerful noninvasive diagnostic toolSpin echo signalImage acquisitionFieldCoilNew approach
2022
Design of an asymmetric spiral RF coil for RF spatial encoding
Ha Y, Selvaganesan K, Hancock K, Galiana G, Constable R. Design of an asymmetric spiral RF coil for RF spatial encoding. Proceedings Of The International Society For Magnetic Resonance In Medicine ... Scientific Meeting And Exhibition. 2022 DOI: 10.58530/2022/3583.Peer-Reviewed Original Research
2014
Accelerate Data Acquisition using Turbo Spin Echo and O-Space
Wang H, Tam L, Kopanoglu E, Peters D, Constable R, Galiana G. Accelerate Data Acquisition using Turbo Spin Echo and O-Space. 2014, 874-877. DOI: 10.1109/isbi.2014.6868010.Peer-Reviewed Original Research