2023
B1 inhomogeneity‐corrected T1 mapping and quantitative magnetization transfer imaging via simultaneously estimating Bloch‐Siegert shift and magnetization transfer effects
Jang A, Han P, Ma C, Fakhri G, Wang N, Samsonov A, Liu F. B1 inhomogeneity‐corrected T1 mapping and quantitative magnetization transfer imaging via simultaneously estimating Bloch‐Siegert shift and magnetization transfer effects. Magnetic Resonance In Medicine 2023, 90: 1859-1873. PMID: 37427533, PMCID: PMC10528411, DOI: 10.1002/mrm.29778.Peer-Reviewed Original ResearchConceptsBloch-Siegert shiftBloch-SiegertMagnetization transfer effectsMonte Carlo simulationsSpin-lattice relaxationSpin-bath modelMagnetization transferBinary spin-bath modelCarlo simulationsProton fractionOff-resonance irradiationIn vivo brain studiesBloch simulationsPhantom experimentsMagnetizationEstimationTransmitted fieldQuantitative magnetization transferMethod performanceMT effectSignal equation
2021
Free‐breathing 3D cardiac T1 mapping with transmit B1 correction at 3T
Han P, Marin T, Djebra Y, Landes V, Zhuo Y, Fakhri G, Ma C. Free‐breathing 3D cardiac T1 mapping with transmit B1 correction at 3T. Magnetic Resonance In Medicine 2021, 87: 1832-1845. PMID: 34812547, PMCID: PMC8810588, DOI: 10.1002/mrm.29097.Peer-Reviewed Original ResearchMeSH KeywordsHeartHumansImage Interpretation, Computer-AssistedMagnetic Resonance ImagingPhantoms, ImagingReproducibility of ResultsConceptsFlip-angle estimationCardiac T<sub>1</sub> mappingGradient echo readoutThrough-plane spatial resolutionImaging timePractical imaging timesFree breathingPhantom studyB1 correctionAccelerated imagingIn-planeT)-spaceMyocardial T<sub>1</sub> valuesSubspace-based methodsSpatial resolutionImaging experimentsAcquisition schemeT)-space dataSubject-specific timeCorrectionModified Look-Locker inversion recoveryLook-Locker inversion recoveryTime of data acquisitionAverage imaging timeInversion-recovery sequence
2020
MR‐based PET attenuation correction using a combined ultrashort echo time/multi‐echo Dixon acquisition
Han P, Horng D, Gong K, Petibon Y, Kim K, Li Q, Johnson K, Fakhri G, Ouyang J, Ma C. MR‐based PET attenuation correction using a combined ultrashort echo time/multi‐echo Dixon acquisition. Medical Physics 2020, 47: 3064-3077. PMID: 32279317, PMCID: PMC7375929, DOI: 10.1002/mp.14180.Peer-Reviewed Original ResearchConceptsLinear attenuation coefficientPositron emission tomography attenuation correctionPhysical compartmental modelAttenuation correctionShort T<sub>2</sub> componentPET attenuation correctionRadial k-space trajectoryMagnetic resonance (MR)-based methodK-space trajectoriesRadial trajectoryK-spaceAttenuation coefficientDixon acquisitionsPositron emission tomographyWhole white matterMuting methodImage reconstructionImaging speedMR signalMRAC methodPositron emission tomography imagingCorrectionGray matter regionsPhantomMatter regions
2019
Body motion detection and correction in cardiac PET: Phantom and human studies
Sun T, Petibon Y, Han P, Ma C, Kim S, Alpert N, Fakhri G, Ouyang J. Body motion detection and correction in cardiac PET: Phantom and human studies. Medical Physics 2019, 46: 4898-4906. PMID: 31508827, PMCID: PMC6842053, DOI: 10.1002/mp.13815.Peer-Reviewed Original ResearchMeSH KeywordsArtifactsFluorodeoxyglucose F18HeartHumansImage Processing, Computer-AssistedMovementPhantoms, ImagingPositron-Emission TomographyConceptsList-mode dataMotion-compensated image reconstructionMotion correctionCenter of massPET list-mode dataMotion correction methodMotion detectionMotion estimationImage reconstructionPatient body motionDegrade image qualityNonrigid registrationImage qualityMotion transformationCoincident distributionBody motion detectionCardiac positron emission tomographyBack-projection techniqueCovariance matrixImage volumesBody motionPositron emission tomographyBack-projectionReference framePhantom
2017
A minimum-phase Shinnar-Le Roux spectral-spatial excitation RF pulse for simultaneous water and lipid suppression in 1H-MRSI of body extremities
Han P, Ma C, Deng K, Hu S, Jee K, Ying K, Chen Y, Fakhri G. A minimum-phase Shinnar-Le Roux spectral-spatial excitation RF pulse for simultaneous water and lipid suppression in 1H-MRSI of body extremities. Magnetic Resonance Imaging 2017, 45: 18-25. PMID: 28917812, PMCID: PMC5709164, DOI: 10.1016/j.mri.2017.09.008.Peer-Reviewed Original ResearchMeSH KeywordsAlgorithmsHumansImage Processing, Computer-AssistedLegLipidsMagnetic Resonance SpectroscopyMuscle, SkeletalPhantoms, ImagingProtonsWater
2016
DC artifact correction for arbitrary phase-cycling sequence
Han P, Park H, Park S. DC artifact correction for arbitrary phase-cycling sequence. Magnetic Resonance Imaging 2016, 38: 21-26. PMID: 27998747, DOI: 10.1016/j.mri.2016.12.015.Peer-Reviewed Original Research