2015
Multimodality 3D Tumor Segmentation in HCC Patients Treated with TACE
Wang Z, Chapiro J, Schernthaner R, Duran R, Chen R, Geschwind JF, Lin M. Multimodality 3D Tumor Segmentation in HCC Patients Treated with TACE. Academic Radiology 2015, 22: 840-845. PMID: 25863795, PMCID: PMC4464945, DOI: 10.1016/j.acra.2015.03.001.Peer-Reviewed Original ResearchAdultAgedAged, 80 and overAlgorithmsAntibiotics, AntineoplasticCarcinoma, HepatocellularChemoembolization, TherapeuticCone-Beam Computed TomographyDoxorubicinFemaleHumansImage EnhancementImage Interpretation, Computer-AssistedImaging, Three-DimensionalKidney NeoplasmsMagnetic Resonance ImagingMaleMiddle AgedMultidetector Computed TomographyMultimodal ImagingPattern Recognition, AutomatedPrognosisReproducibility of ResultsRetrospective StudiesSensitivity and SpecificitySubtraction TechniqueTreatment Outcome
2014
Three-dimensional Evaluation of Lipiodol Retention in HCC after Chemoembolization A Quantitative Comparison between CBCT and MDCT
Wang Z, Lin M, Lesage D, Chen R, Chapiro J, Gu T, Tacher V, Duran R, Geschwind JF. Three-dimensional Evaluation of Lipiodol Retention in HCC after Chemoembolization A Quantitative Comparison between CBCT and MDCT. Academic Radiology 2014, 21: 393-399. PMID: 24507426, PMCID: PMC3979929, DOI: 10.1016/j.acra.2013.11.006.Peer-Reviewed Original ResearchAgedAntineoplastic AgentsCarcinoma, HepatocellularChemoembolization, TherapeuticCone-Beam Computed TomographyEthiodized OilFemaleHemostaticsHumansImaging, Three-DimensionalLiver NeoplasmsMaleMetabolic Clearance RateMiddle AgedMultidetector Computed TomographyReproducibility of ResultsSensitivity and SpecificityTissue DistributionTreatment Outcome
2013
Quantitative Assessment of Lipiodol Deposition after Chemoembolization: Comparison between Cone-Beam CT and Multidetector CT
Chen R, Geschwind J, Wang Z, Tacher V, Lin M. Quantitative Assessment of Lipiodol Deposition after Chemoembolization: Comparison between Cone-Beam CT and Multidetector CT. Journal Of Vascular And Interventional Radiology 2013, 24: 1837-1844. PMID: 24094672, PMCID: PMC3840104, DOI: 10.1016/j.jvir.2013.08.017.Peer-Reviewed Original ResearchMeSH KeywordsCarcinoma, HepatocellularChemoembolization, TherapeuticCone-Beam Computed TomographyContrast MediaEthiodized OilFemaleHumansImaging, Three-DimensionalLinear ModelsLiver NeoplasmsMaleMiddle AgedMultidetector Computed TomographyPredictive Value of TestsRadiographic Image Interpretation, Computer-AssistedRetrospective StudiesTumor BurdenWorkflowConceptsTransarterial chemoembolizationLipiodol depositionHepatocellular carcinomaMultidetector CTConventional transarterial chemoembolizationVolume of tumorMargin of tumorUnenhanced multidetector CTUnenhanced multidetectorLipiodol retentionChemoembolizationLiver parenchymaTumorsEntire tumorLiver contrastCone beamCone-beam CTCTImaging modalitiesCBCTPatientsLipiodolWhole tumorVolumetric measurementsTomographyImage Guidance for Endovascular Repair of Complex Aortic Aneurysms: Comparison of Two-dimensional and Three-dimensional Angiography and Image Fusion
Tacher V, Lin M, Desgranges P, Deux J, Grünhagen T, Becquemin J, Luciani A, Rahmouni A, Kobeiter H. Image Guidance for Endovascular Repair of Complex Aortic Aneurysms: Comparison of Two-dimensional and Three-dimensional Angiography and Image Fusion. Journal Of Vascular And Interventional Radiology 2013, 24: 1698-1706. PMID: 24035418, PMCID: PMC3888792, DOI: 10.1016/j.jvir.2013.07.016.Peer-Reviewed Original ResearchMeSH KeywordsAgedAged, 80 and overAnatomic LandmarksAngiography, Digital SubtractionAortic AneurysmAortographyBlood Vessel Prosthesis ImplantationCone-Beam Computed TomographyContrast MediaEndovascular ProceduresFeasibility StudiesFemaleFluoroscopyHumansImaging, Three-DimensionalMaleMiddle AgedMultidetector Computed TomographyOperative TimePredictive Value of TestsRadiation DosageRadiographic Image Interpretation, Computer-AssistedRadiography, InterventionalRetrospective StudiesSoftwareTime FactorsTreatment OutcomeConceptsComplex aortic aneurysmsContrast medium volumeAortic aneurysmProcedure timeEndovascular repairComplex aneurysm repairJuxtarenal aortic aneurysmsContrast agent volumeSignificant differencesX-ray exposureSignificant reductionImage guidance groupThree-dimensional angiographyIntraprocedural fluoroscopyAneurysm repairConsecutive patientsPatient characteristicsEndovascular techniquesRenal arteryIF groupAneurysmsDAP valuesAngiographyGuidance groupStatistical difference
2012
Comparison of Semi-automatic Volumetric VX2 Hepatic Tumor Segmentation from Cone Beam CT and Multi-detector CT with Histology in Rabbit Models
Pellerin O, Lin M, Bhagat N, Ardon R, Mory B, Geschwind J. Comparison of Semi-automatic Volumetric VX2 Hepatic Tumor Segmentation from Cone Beam CT and Multi-detector CT with Histology in Rabbit Models. Academic Radiology 2012, 20: 115-121. PMID: 22947274, PMCID: PMC3575098, DOI: 10.1016/j.acra.2012.07.011.Peer-Reviewed Original ResearchMeSH KeywordsAnimalsCell Line, TumorCone-Beam Computed TomographyContrast MediaLinear ModelsLiver NeoplasmsMaleMultidetector Computed TomographyRabbitsSoftwareTumor Burden