2021
PET Image Denoising Using a Deep-Learning Method for Extremely Obese Patients
Liu H, Yousefi H, Mirian N, Lin M, Menard D, Gregory M, Aboian M, Boustani A, Chen M, Saperstein L, Pucar D, Kulon M, Liu C. PET Image Denoising Using a Deep-Learning Method for Extremely Obese Patients. IEEE Transactions On Radiation And Plasma Medical Sciences 2021, 6: 766-770. PMID: 37284026, PMCID: PMC10241407, DOI: 10.1109/trpms.2021.3131999.Peer-Reviewed Original ResearchGeneration of parametric Ki images for FDG PET using two 5‐min scans
Wu J, Liu H, Ye Q, Gallezot J, Naganawa M, Miao T, Lu Y, Chen M, Esserman DA, Kyriakides TC, Carson RE, Liu C. Generation of parametric Ki images for FDG PET using two 5‐min scans. Medical Physics 2021, 48: 5219-5231. PMID: 34287939, DOI: 10.1002/mp.15113.Peer-Reviewed Original ResearchConceptsPopulation-based input functionDynamic FDG-PET scansFDG-PET scansFDG-PETSUV changesPET scansClinical practiceSolid lung nodulesClinical usefulnessLate scansBone marrowRegion of interestLung nodulesInput functionScansPatlak analysisKi imagesMin/T-testCorrelation coefficientTumorsSubjectsNodulesDynamic imagingPET
2020
Binding of the synaptic vesicle radiotracer [11C]UCB-J is unchanged during functional brain activation using a visual stimulation task
Smart K, Liu H, Matuskey D, Chen MK, Torres K, Nabulsi N, Labaree D, Ropchan J, Hillmer AT, Huang Y, Carson RE. Binding of the synaptic vesicle radiotracer [11C]UCB-J is unchanged during functional brain activation using a visual stimulation task. Cerebrovascular And Brain Metabolism Reviews 2020, 41: 1067-1079. PMID: 32757741, PMCID: PMC8054713, DOI: 10.1177/0271678x20946198.Peer-Reviewed Original ResearchConceptsVisual cortexVisual stimulationPositron emission tomography radioligandBrain activationBlood flow increasesVolume of distributionPrimary visual cortexCheckerboard visual stimulationFunctional brain activationFunctional magnetic resonanceReference tissue modelFMRI BOLD responsesSynaptic densityVisual stimulation taskOne-tissue compartment modelHealthy volunteersNeuronal firingTomography radioligandPET scansTissue influxVivo measuresRobust increaseBOLD responseTracer influxStimulation task
2018
Improved discrimination between benign and malignant LDCT screening-detected lung nodules with dynamic over static 18F-FDG PET as a function of injected dose
Ye Q, Wu J, Lu Y, Naganawa M, Gallezot JD, Ma T, Liu Y, Tanoue L, Detterbeck F, Blasberg J, Chen MK, Casey M, Carson RE, Liu C. Improved discrimination between benign and malignant LDCT screening-detected lung nodules with dynamic over static 18F-FDG PET as a function of injected dose. Physics In Medicine And Biology 2018, 63: 175015. PMID: 30095083, PMCID: PMC6158045, DOI: 10.1088/1361-6560/aad97f.Peer-Reviewed Original ResearchConceptsPopulation-based input functionStandardized uptake valueImage-derived input functionLung nodulesClinical trialsTime-activity curvesLow-dose computed tomography (LDCT) screeningLung cancer mortality ratesIndeterminate lung nodulesComputed Tomography ScreeningF-FDG PETCancer mortality ratesStatic PET acquisitionVirtual clinical trialsScan durationTomography screeningFDG injectionPET scansMortality rateUptake valueAccurate diagnosisMalignant lung nodulesROC analysisPatient dataMalignant nodules