2019
MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiac 18F-FDG imaging
Petibon Y, Sun T, Han P, Ma C, Fakhri G, Ouyang J. MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiac 18F-FDG imaging. Physics In Medicine And Biology 2019, 64: 195009. PMID: 31394518, PMCID: PMC7007962, DOI: 10.1088/1361-6560/ab39c2.Peer-Reviewed Original ResearchConceptsMR-based motion correctionRespiratory motion correctionMotion correctionImproved spatial resolutionReconstructed activity concentrationCardiac PET dataSpatial resolutionCoincidence eventsMR-basedPET imagingContrast-to-noise ratioCardiac PET imagingRespiratory phasesMC dataImprove image qualityMR acquisitionQuantitative accuracyCardiac PETPET dataActivity concentrationsMyocardium wallF-FDG PETDynamics studiesImage qualityMotion artifactsFree-Breathing Three-Dimensional T1 Mapping of the Heart Using Subspace-Based Data Acquisition and Image Reconstruction
Han P, Horng D, Marin T, Petibon Y, Ouyang J, Fakhri G, Ma C. Free-Breathing Three-Dimensional T1 Mapping of the Heart Using Subspace-Based Data Acquisition and Image Reconstruction. Annual International Conference Of The IEEE Engineering In Medicine And Biology Society (EMBC) 2019, 00: 4008-4011. PMID: 31946750, DOI: 10.1109/embc.2019.8856511.Peer-Reviewed Original ResearchConceptsRespiratory motionRespiratory gatingLongitudinal relaxation timeSubspace-based methodsLow-rank tensorMagnetic resonance imagingRelaxation timeT1 mappingT)-spaceSubspace-basedSparsity constraintDynamic MR imagingReconstructed mapsSpatiotemporal correlationThree-dimensionalCardiac MRHealthy subjectsIn vivo dataMagnetizationResonance imagingImage functionMR imagingData acquisitionClinical applicationTensor
2018
Joint reconstruction of rest/stress myocardial perfusion SPECT
Lai X, Petibon Y, Fakhri G, Ouyang J. Joint reconstruction of rest/stress myocardial perfusion SPECT. Physics In Medicine And Biology 2018, 63: 135019. PMID: 29897044, PMCID: PMC6245543, DOI: 10.1088/1361-6560/aacc2f.Peer-Reviewed Original ResearchConceptsMyocardial perfusion imagingSingle photon emission computed tomographyReversible defectsSignal-to-noise ratioRest/stress SPECT myocardial perfusion imagingSPECT myocardial perfusion imagingConventional subtraction methodDefect detectionJoint methodPhoton emission computed tomographySubtraction methodReverse mappingClinical dose levelsEmission computed tomographyImprove defect detectionLow noiseNon-invasive assessmentClinical dosePerfusion defectsReduced doseImprove radiologists' performanceReconstruction frameworkRest imagesPerfusion imagingDose levels
2016
Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR
Petibon Y, Guehl N, Reese T, Ebrahimi B, Normandin M, Shoup T, Alpert N, Fakhri G, Ouyang J. Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR. Physics In Medicine And Biology 2016, 62: 326-343. PMID: 27997375, PMCID: PMC5241952, DOI: 10.1088/1361-6560/aa5087.Peer-Reviewed Original ResearchConceptsSimultaneous PET-MRPET myocardial perfusion imagingMyocardial perfusion imagingPoint spread functionPoint-spread function correctionUngated dataMotion correctionPET-MRPartial volume effectsApparent wall thicknessMyocardial blood flowPartial volume effect correctionMR-based motion correctionMotion fieldPET-MR scannersPoint spread function modelPET dataPerfusion imagingImage qualityImpact of motionDynamic myocardial perfusion imagingAttenuation mapNon-rigid registrationAbsolute myocardial blood flowUngated images
2014
Myocardial Defect Detection Using PET-CT: Phantom Studies
Mananga E, Fakhri G, Schaefferkoetter J, Bonab A, Ouyang J. Myocardial Defect Detection Using PET-CT: Phantom Studies. PLOS ONE 2014, 9: e88200. PMID: 24505429, PMCID: PMC3914931, DOI: 10.1371/journal.pone.0088200.Peer-Reviewed Original ResearchMeSH KeywordsAlgorithmsEquipment DesignFemaleHumansMaleMyocardiumPhantoms, ImagingPositron-Emission TomographyConceptsMyocardial defect detectionFiltered back projectionChannelized Hotelling observerPhantom studyActivity distributionSubset expectation maximizationDefect detectionCardiac PET studiesMyocardial defectsHotelling observerNoise levelBack-projectionPET-CTPhantomExpectation maximizationOP-OSEMReconstruction schemePET studiesOSEMDefectsNoise
2013
Cardiac motion compensation and resolution modeling in simultaneous PET-MR: a cardiac lesion detection study
Petibon Y, Ouyang J, Zhu X, Huang C, Reese T, Chun S, Li Q, Fakhri G. Cardiac motion compensation and resolution modeling in simultaneous PET-MR: a cardiac lesion detection study. Physics In Medicine And Biology 2013, 58: 2085-2102. PMID: 23470288, PMCID: PMC3657754, DOI: 10.1088/0031-9155/58/7/2085.Peer-Reviewed Original ResearchConceptsContrast recoveryDetector point spread functionPartial volume effectsK-spaceMotion compensationB-spline registrationLesion-detection studiesCardiac motion compensationPET-MR scannersSimultaneous PET-MRPET contrastIterative reconstruction frameworkPoint spread functionMotion correctionPET countsNon-rigid B-spline registrationCardiac phantomPSF modelPET-MRMotion deblurringReconstruction frameworkSystem matrixCardiac PETSpread functionDefect detection