2014
Towards coronary plaque imaging using simultaneous PET-MR: a simulation study
Petibon Y, Fakhri G, Nezafat R, Johnson N, Brady T, Ouyang J. Towards coronary plaque imaging using simultaneous PET-MR: a simulation study. Physics In Medicine And Biology 2014, 59: 1203-1222. PMID: 24556608, PMCID: PMC4061607, DOI: 10.1088/0031-9155/59/5/1203.Peer-Reviewed Original ResearchMeSH KeywordsComputer SimulationCoronary AngiographyCoronary StenosisHumansImage Interpretation, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance AngiographyModels, CardiovascularMultimodal ImagingPhantoms, ImagingPositron-Emission TomographyReproducibility of ResultsSensitivity and SpecificityConceptsSimultaneous PET-MRChannelized Hotelling observerAttenuation mapMotion correctionPET-MRFluorodeoxyglucose-positron emission tomography imagingRespiratory motion fieldsMotion correction methodCho SNRMotion correction techniqueAnthropomorphic phantomUncorrected reconstructionsRespiratory motionXCAT phantomCoronary plaque imagingMonte Carlo simulationsPET reconstructionXCATActivity distributionCardiac gatingNon-rigid registrationHotelling observerCarlo simulationsPlaque imagingPhantom
2009
Quantitative simultaneous cardiac SPECT using MC‐JOSEM
Ouyang J, Zhu X, Trott C, Fakhri G. Quantitative simultaneous cardiac SPECT using MC‐JOSEM. Medical Physics 2009, 36: 602-611. PMID: 19292000, PMCID: PMC2673670, DOI: 10.1118/1.3063544.Peer-Reviewed Original ResearchConceptsMC-JOSEMEnergy windowWater-filled torso phantomScatter correctionPhotopeak energy windowStandard OSEMCardiac SPECT imagingActivity concentration ratioIterative reconstruction algorithmReconstruction algorithmMyocardium wallTorso phantomActivity estimationDetector responseEmission energyBackground compartmentPhantom dataCardiac SPECTActivity distributionRest/stress imagingScatteringCases of patientsOSEMChest painCardiac protocols
2007
Fast Monte Carlo based joint iterative reconstruction for simultaneous SPECT imaging
Ouyang J, Fakhri G, Moore S. Fast Monte Carlo based joint iterative reconstruction for simultaneous SPECT imaging. Medical Physics 2007, 34: 3263-3272. PMID: 17879789, DOI: 10.1118/1.2756601.Peer-Reviewed Original ResearchConceptsMC-JOSEMEnergy windowFast Monte CarloSignal-to-noise ratioScatter correction methodOrdered-subsets expectation-maximizationMonte CarloOrdered-subsets expectation-maximization algorithmIterative reconstruction algorithmPrimary photonsReconstruction algorithmPhoton transportSeptal penetrationDetector responseMC simulationsIterative reconstructionAttenuation distributionStandard OSEMPhotonsProjection dataPatient-specific activityDetectorReconstructed imagesScatteringEstimation of scattering
2006
Generalized five‐dimensional dynamic and spectral factor analysis
Fakhri G, Sitek A, Zimmerman R, Ouyang J. Generalized five‐dimensional dynamic and spectral factor analysis. Medical Physics 2006, 33: 1016-1024. PMID: 16696478, DOI: 10.1118/1.2179168.Peer-Reviewed Original Research
2005
Performance of a novel collimator for high‐sensitivity brain SPECT
Fakhri G, Ouyang J, Zimmerman R, Fischman A, Kijewski M. Performance of a novel collimator for high‐sensitivity brain SPECT. Medical Physics 2005, 33: 209-215. PMID: 16485427, DOI: 10.1118/1.2143140.Peer-Reviewed Original ResearchMeSH KeywordsBrainEquipment DesignEquipment Failure AnalysisHumansImage EnhancementPhantoms, ImagingReproducibility of ResultsSensitivity and SpecificityTomography, Emission-Computed, Single-PhotonConceptsSphere activity concentrationNPW-SNRStandard collimatorSphere-to-background activity ratiosAttenuation of countsPhantom centerActivity concentrationsPoint spread functionCentral regionCollimatorPhantom studyStriatal phantomCylindrical backgroundResolution recoveryPhantomSpherical lesionsRamp filterCrystal surfaceSpread functionSignal-to-noise ratioCentral brain structuresFitting imageHealthy volunteersBrain SPECTSphere activity