2023
Super-resolution in brain positron emission tomography using a real-time motion capture system
Chemli Y, Tétrault M, Marin T, Normandin M, Bloch I, El Fakhri G, Ouyang J, Petibon Y. Super-resolution in brain positron emission tomography using a real-time motion capture system. NeuroImage 2023, 272: 120056. PMID: 36977452, PMCID: PMC10122782, DOI: 10.1016/j.neuroimage.2023.120056.Peer-Reviewed Original ResearchConceptsBrain positron emission tomographySuper-resolutionEvent-by-event basisReal-time motion capture systemSR reconstruction methodTracking cameraVisualization of small structuresPET reconstruction algorithmMoving phantomMeasure target motionLine profilesPET/CT scannerMeasured shiftsImprove image resolutionMotion capture systemMotion tracking devicePositron emission tomographyReconstruction algorithmSpatial resolutionMeasured linesPhantomReal-timeEstimation frameworkIncreased spatial resolutionReconstruction method
2016
Investigation of cone-beam CT image quality trade-off for image-guided radiation therapy
Bian J, Sharp G, Park Y, Ouyang J, Bortfeld T, Fakhri G. Investigation of cone-beam CT image quality trade-off for image-guided radiation therapy. Physics In Medicine And Biology 2016, 61: 3317-3346. PMID: 27032676, DOI: 10.1088/0031-9155/61/9/3317.Peer-Reviewed Original ResearchConceptsImage-guided radiation therapyCone-beam CTFiltered-backprojectionImage quality trade-offConventional filtered-backprojectionShort-scan reconstructionsFiltered-backprojection algorithmFan-beam reconstructionTV-based algorithmIterative reconstruction algorithmCatphan phantomRadiation therapyAngular rangeTotal-variationOptimal exposure levelClinical scannerScanning configurationReconstruction algorithmImaging conditionsCatphanPhantomExposure levelsTherapyConfigurationRange
2013
Magnetic Resonance-Based Motion Correction for Positron Emission Tomography Imaging
Ouyang J, Li Q, Fakhri G. Magnetic Resonance-Based Motion Correction for Positron Emission Tomography Imaging. Seminars In Nuclear Medicine 2013, 43: 60-67. PMID: 23178089, PMCID: PMC3508789, DOI: 10.1053/j.semnuclmed.2012.08.007.Peer-Reviewed Original ResearchConceptsMotion correctionClinical whole-body PET scannersMotion-corrected PET imagesWhole-body PET scannerPET motion correctionNonrigid image registration algorithmAcquired MR imagesRespiratory motionImage registration algorithmPET scannerSimultaneous PET/magnetic resonancePET reconstructionSimultaneous PET/MRPatient motionImage qualityIterative PET reconstructionPET/MR studiesPET/magnetic resonanceAttenuating mediaImage artifactsRegistration algorithmSpatial resolutionReconstruction algorithmPositron emission tomographyMR imaging techniques
2009
Quantitative simultaneous cardiac SPECT using MC‐JOSEM
Ouyang J, Zhu X, Trott C, Fakhri G. Quantitative simultaneous cardiac SPECT using MC‐JOSEM. Medical Physics 2009, 36: 602-611. PMID: 19292000, PMCID: PMC2673670, DOI: 10.1118/1.3063544.Peer-Reviewed Original ResearchConceptsMC-JOSEMEnergy windowWater-filled torso phantomScatter correctionPhotopeak energy windowStandard OSEMCardiac SPECT imagingActivity concentration ratioIterative reconstruction algorithmReconstruction algorithmMyocardium wallTorso phantomActivity estimationDetector responseEmission energyBackground compartmentPhantom dataCardiac SPECTActivity distributionRest/stress imagingScatteringCases of patientsOSEMChest painCardiac protocols
2008
Improved activity estimation with MC‐JOSEM versus TEW‐JOSEM in SPECT
Ouyang J, Fakhri G, Moore S. Improved activity estimation with MC‐JOSEM versus TEW‐JOSEM in SPECT. Medical Physics 2008, 35: 2029-2040. PMID: 18561679, PMCID: PMC2673642, DOI: 10.1118/1.2907561.Peer-Reviewed Original ResearchMeSH KeywordsAlgorithmsEquipment DesignImage Processing, Computer-AssistedIndium RadioisotopesLungModels, StatisticalMonte Carlo MethodPhantoms, ImagingRadiotherapy Planning, Computer-AssistedReproducibility of ResultsScattering, RadiationSoftwareTomography, Emission-Computed, Single-PhotonTomography, X-Ray ComputedConceptsMC-JOSEMWater-filled torso phantomMC scatter estimationTriple-energy-windowActivity estimationIterative reconstruction algorithmTorso phantomPhantom studyBackground compartmentScatter estimationActivity distributionAverage relative biasPhantomReconstruction algorithmActivity concentrationsSynthetic projectionsSphere locationScattering
2007
Fast Monte Carlo based joint iterative reconstruction for simultaneous SPECT imaging
Ouyang J, Fakhri G, Moore S. Fast Monte Carlo based joint iterative reconstruction for simultaneous SPECT imaging. Medical Physics 2007, 34: 3263-3272. PMID: 17879789, DOI: 10.1118/1.2756601.Peer-Reviewed Original ResearchConceptsMC-JOSEMEnergy windowFast Monte CarloSignal-to-noise ratioScatter correction methodOrdered-subsets expectation-maximizationMonte CarloOrdered-subsets expectation-maximization algorithmIterative reconstruction algorithmPrimary photonsReconstruction algorithmPhoton transportSeptal penetrationDetector responseMC simulationsIterative reconstructionAttenuation distributionStandard OSEMPhotonsProjection dataPatient-specific activityDetectorReconstructed imagesScatteringEstimation of scattering
2006
Monte Carlo-based compensation for patient scatter, detector scatter, and crosstalk contamination in In-111 SPECT imaging
Moore S, Ouyang J, Park M, Fakhri G. Monte Carlo-based compensation for patient scatter, detector scatter, and crosstalk contamination in In-111 SPECT imaging. Nuclear Instruments And Methods In Physics Research Section A Accelerators Spectrometers Detectors And Associated Equipment 2006, 569: 472-476. DOI: 10.1016/j.nima.2006.08.079.Peer-Reviewed Original ResearchScatter projectionsPatient scatterDetector scatterOrgan activity estimatesPhoton interaction pointIterative reconstruction algorithmDetector effectsEnergy binsReconstruction algorithmDelta scatteringTorso phantomPoint spread functionSegmented CT scanInteraction pointOSEM reconstructionNumerical phantomDetectorScatteringScattering mapSpherical tumorSpread functionImage noisePhantomActivity concentrationsActivity estimationCompensation for Patient and Detector Scatter and Crosstalk Contamination in111In SPECT Using Fast Monte Carlo-based Iterative Reconstruction
Ouyang J, Fakhri G, Zimmerman R, Moore S. Compensation for Patient and Detector Scatter and Crosstalk Contamination in111In SPECT Using Fast Monte Carlo-based Iterative Reconstruction. 2006, 5: 2851-2853. DOI: 10.1109/nssmic.2006.356471.Peer-Reviewed Original ResearchFast Monte Carlo Simulation Based Joint Iterative Reconstruction for Simultaneous 99mTc/123I Brain SPECT Imaging
Ouyang J, Fakhri G, Moore S, Kijewski M. Fast Monte Carlo Simulation Based Joint Iterative Reconstruction for Simultaneous 99mTc/123I Brain SPECT Imaging. 2006, 4: 2251-2256. DOI: 10.1109/nssmic.2006.354362.Peer-Reviewed Original ResearchMC-JOSEMAW-OSEMMonte CarloFast Monte CarloIterative reconstructionOrdered-subset expectation maximizationStandard ordered subsetsIterative reconstruction algorithmScattered photonsPhoton transportSeptal penetrationAttenuation distributionPhysical effectsIdentical physiological conditionsPatient-specific activityReconstructed imagesReconstruction algorithmActivity estimationComptonRoot mean square errorPhotonsCorrection methodCollimatorBrain perfusionDetector