2022
Cardiac PET/MR Basics
Petibon Y, Ma C, Ouyang J, El Fakhri G. Cardiac PET/MR Basics. 2022, 21-35. DOI: 10.1007/978-3-031-09807-9_2.Peer-Reviewed Original ResearchMeasuring organ motionPET motion correctionFront-end electronicsScintillation detectorOrgan motionMotion correctionAttenuation correctionPET/MR scannersAbility of MRISimultaneous imaging modalityPET/MR technologyAttenuation propertiesHybrid PET/MR scannerPET/MRPre-clinicalImaging modalitiesClinical applicationMRIOrgan systemsCardiac applicationsImaging opportunitiesCorrectionDetectorSpatiotemporal resolutionElectron
2021
Investigation of a Model-Based Time-Over-Threshold Technique for Phoswich Crystal Discrimination
Bouziri H, Pepin C, Koua K, Benhouria M, Paulin C, Ouyang J, Normandin M, Pratte J, Fakhri G, Lecomte R, Fontaine R. Investigation of a Model-Based Time-Over-Threshold Technique for Phoswich Crystal Discrimination. IEEE Transactions On Radiation And Plasma Medical Sciences 2021, 6: 393-403. PMID: 35372739, PMCID: PMC8974315, DOI: 10.1109/trpms.2021.3077412.Peer-Reviewed Original ResearchPulse shape discriminationCrystal identificationPhoswich detectorEnergy windowTime-over-threshold techniqueBroad energy windowCR-RC shaperCharge sensitive preamplifierFree running analogPhoswich assembliesLYSO scintillatorSensitive preamplifierCrystal discriminationAPD arraysShape discriminationEvent energyElectronic readoutTime of occurenceDecay timeLGSODetectorIncreasing pixelizationLYSODetection front endCrystal
2007
Fast Monte Carlo based joint iterative reconstruction for simultaneous SPECT imaging
Ouyang J, Fakhri G, Moore S. Fast Monte Carlo based joint iterative reconstruction for simultaneous SPECT imaging. Medical Physics 2007, 34: 3263-3272. PMID: 17879789, DOI: 10.1118/1.2756601.Peer-Reviewed Original ResearchConceptsMC-JOSEMEnergy windowFast Monte CarloSignal-to-noise ratioScatter correction methodOrdered-subsets expectation-maximizationMonte CarloOrdered-subsets expectation-maximization algorithmIterative reconstruction algorithmPrimary photonsReconstruction algorithmPhoton transportSeptal penetrationDetector responseMC simulationsIterative reconstructionAttenuation distributionStandard OSEMPhotonsProjection dataPatient-specific activityDetectorReconstructed imagesScatteringEstimation of scattering
2006
Monte Carlo-based compensation for patient scatter, detector scatter, and crosstalk contamination in In-111 SPECT imaging
Moore S, Ouyang J, Park M, Fakhri G. Monte Carlo-based compensation for patient scatter, detector scatter, and crosstalk contamination in In-111 SPECT imaging. Nuclear Instruments And Methods In Physics Research Section A Accelerators Spectrometers Detectors And Associated Equipment 2006, 569: 472-476. DOI: 10.1016/j.nima.2006.08.079.Peer-Reviewed Original ResearchScatter projectionsPatient scatterDetector scatterOrgan activity estimatesPhoton interaction pointIterative reconstruction algorithmDetector effectsEnergy binsReconstruction algorithmDelta scatteringTorso phantomPoint spread functionSegmented CT scanInteraction pointOSEM reconstructionNumerical phantomDetectorScatteringScattering mapSpherical tumorSpread functionImage noisePhantomActivity concentrationsActivity estimationCompensation for Patient and Detector Scatter and Crosstalk Contamination in111In SPECT Using Fast Monte Carlo-based Iterative Reconstruction
Ouyang J, Fakhri G, Zimmerman R, Moore S. Compensation for Patient and Detector Scatter and Crosstalk Contamination in111In SPECT Using Fast Monte Carlo-based Iterative Reconstruction. 2006, 5: 2851-2853. DOI: 10.1109/nssmic.2006.356471.Peer-Reviewed Original ResearchFast Monte Carlo Simulation Based Joint Iterative Reconstruction for Simultaneous 99mTc/123I Brain SPECT Imaging
Ouyang J, Fakhri G, Moore S, Kijewski M. Fast Monte Carlo Simulation Based Joint Iterative Reconstruction for Simultaneous 99mTc/123I Brain SPECT Imaging. 2006, 4: 2251-2256. DOI: 10.1109/nssmic.2006.354362.Peer-Reviewed Original ResearchMC-JOSEMAW-OSEMMonte CarloFast Monte CarloIterative reconstructionOrdered-subset expectation maximizationStandard ordered subsetsIterative reconstruction algorithmScattered photonsPhoton transportSeptal penetrationAttenuation distributionPhysical effectsIdentical physiological conditionsPatient-specific activityReconstructed imagesReconstruction algorithmActivity estimationComptonRoot mean square errorPhotonsCorrection methodCollimatorBrain perfusionDetector
2005
Fast Monte Carlo Estimation of Patient and Detector Scatter and Crosstalk Contamination in SPECT Imaging
Ouyang J, Moore S, Park M, Fakhri G. Fast Monte Carlo Estimation of Patient and Detector Scatter and Crosstalk Contamination in SPECT Imaging. 2005, 3: 1560-1562. DOI: 10.1109/nssmic.2005.1596616.Peer-Reviewed Original ResearchDetector effectsEnergy windowTriple-energy window methodConvolution-based forced detectionPhoton interaction pointSimulate photon interactionsLower energy windowScattering mapCompton scatteringPhoton contributionEnergy binsPhoton interactionsMultiple photonsDetector scatterImaging isotopesCoherent scatteringAttenuation phantomMonte Carlo methodPhotoelectric effectInteraction pointPhantom experimentsDetectorCrosstalk contaminationScatteringCarlo method