2009
Quantitative simultaneous cardiac SPECT using MC‐JOSEM
Ouyang J, Zhu X, Trott C, Fakhri G. Quantitative simultaneous cardiac SPECT using MC‐JOSEM. Medical Physics 2009, 36: 602-611. PMID: 19292000, PMCID: PMC2673670, DOI: 10.1118/1.3063544.Peer-Reviewed Original ResearchConceptsMC-JOSEMEnergy windowWater-filled torso phantomScatter correctionPhotopeak energy windowStandard OSEMCardiac SPECT imagingActivity concentration ratioIterative reconstruction algorithmReconstruction algorithmMyocardium wallTorso phantomActivity estimationDetector responseEmission energyBackground compartmentPhantom dataCardiac SPECTActivity distributionRest/stress imagingScatteringCases of patientsOSEMChest painCardiac protocols
2008
Improved activity estimation with MC‐JOSEM versus TEW‐JOSEM in SPECT
Ouyang J, Fakhri G, Moore S. Improved activity estimation with MC‐JOSEM versus TEW‐JOSEM in SPECT. Medical Physics 2008, 35: 2029-2040. PMID: 18561679, PMCID: PMC2673642, DOI: 10.1118/1.2907561.Peer-Reviewed Original ResearchMeSH KeywordsAlgorithmsEquipment DesignImage Processing, Computer-AssistedIndium RadioisotopesLungModels, StatisticalMonte Carlo MethodPhantoms, ImagingRadiotherapy Planning, Computer-AssistedReproducibility of ResultsScattering, RadiationSoftwareTomography, Emission-Computed, Single-PhotonTomography, X-Ray ComputedConceptsMC-JOSEMWater-filled torso phantomMC scatter estimationTriple-energy-windowActivity estimationIterative reconstruction algorithmTorso phantomPhantom studyBackground compartmentScatter estimationActivity distributionAverage relative biasPhantomReconstruction algorithmActivity concentrationsSynthetic projectionsSphere locationScattering
2006
Monte Carlo-based compensation for patient scatter, detector scatter, and crosstalk contamination in In-111 SPECT imaging
Moore S, Ouyang J, Park M, Fakhri G. Monte Carlo-based compensation for patient scatter, detector scatter, and crosstalk contamination in In-111 SPECT imaging. Nuclear Instruments And Methods In Physics Research Section A Accelerators Spectrometers Detectors And Associated Equipment 2006, 569: 472-476. DOI: 10.1016/j.nima.2006.08.079.Peer-Reviewed Original ResearchScatter projectionsPatient scatterDetector scatterOrgan activity estimatesPhoton interaction pointIterative reconstruction algorithmDetector effectsEnergy binsReconstruction algorithmDelta scatteringTorso phantomPoint spread functionSegmented CT scanInteraction pointOSEM reconstructionNumerical phantomDetectorScatteringScattering mapSpherical tumorSpread functionImage noisePhantomActivity concentrationsActivity estimationFast Monte Carlo Simulation Based Joint Iterative Reconstruction for Simultaneous 99mTc/123I Brain SPECT Imaging
Ouyang J, Fakhri G, Moore S, Kijewski M. Fast Monte Carlo Simulation Based Joint Iterative Reconstruction for Simultaneous 99mTc/123I Brain SPECT Imaging. 2006, 4: 2251-2256. DOI: 10.1109/nssmic.2006.354362.Peer-Reviewed Original ResearchMC-JOSEMAW-OSEMMonte CarloFast Monte CarloIterative reconstructionOrdered-subset expectation maximizationStandard ordered subsetsIterative reconstruction algorithmScattered photonsPhoton transportSeptal penetrationAttenuation distributionPhysical effectsIdentical physiological conditionsPatient-specific activityReconstructed imagesReconstruction algorithmActivity estimationComptonRoot mean square errorPhotonsCorrection methodCollimatorBrain perfusionDetector