2021
Use of Mechanical Circulatory Support Devices Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock
Dhruva SS, Ross JS, Mortazavi BJ, Hurley NC, Krumholz HM, Curtis JP, Berkowitz AP, Masoudi FA, Messenger JC, Parzynski CS, Ngufor CG, Girotra S, Amin AP, Shah ND, Desai NR. Use of Mechanical Circulatory Support Devices Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock. JAMA Network Open 2021, 4: e2037748. PMID: 33616664, PMCID: PMC7900859, DOI: 10.1001/jamanetworkopen.2020.37748.Peer-Reviewed Original ResearchMeSH KeywordsAgedAssisted CirculationCross-Sectional StudiesExtracorporeal Membrane OxygenationFemaleHeart ArrestHeart-Assist DevicesHospitals, High-VolumeHospitals, Low-VolumeHospitals, TeachingHumansIntra-Aortic Balloon PumpingMaleMiddle AgedMyocardial InfarctionPercutaneous Coronary InterventionRisk FactorsShock, CardiogenicConceptsMicroaxial left ventricular assist deviceIntra-aortic balloon pumpLeft ventricular assist devicePercutaneous coronary interventionAcute myocardial infarctionMechanical circulatory support devicesCardiogenic shockHospital-level variationSignificant hospital-level variationCirculatory support devicesMCS devicesUse of IABPDevice useMedian proportionAcute Myocardial Infarction ComplicatedCardiology-National Cardiovascular Data RegistryChest Pain-MI RegistryLimited clinical trial evidenceNational Cardiovascular Data RegistryMyocardial Infarction ComplicatedFirst medical contactSupport devicesClinical trial evidenceExtracorporeal membrane oxygenationCoronary artery stenosis
2020
Association of Use of an Intravascular Microaxial Left Ventricular Assist Device vs Intra-aortic Balloon Pump With In-Hospital Mortality and Major Bleeding Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock
Dhruva SS, Ross JS, Mortazavi BJ, Hurley NC, Krumholz HM, Curtis JP, Berkowitz A, Masoudi FA, Messenger JC, Parzynski CS, Ngufor C, Girotra S, Amin AP, Shah ND, Desai NR. Association of Use of an Intravascular Microaxial Left Ventricular Assist Device vs Intra-aortic Balloon Pump With In-Hospital Mortality and Major Bleeding Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock. JAMA 2020, 323: 734-745. PMID: 32040163, PMCID: PMC7042879, DOI: 10.1001/jama.2020.0254.Peer-Reviewed Original ResearchMeSH KeywordsAgedCause of DeathExtracorporeal Membrane OxygenationFemaleHeart ArrestHeart-Assist DevicesHemorrhageHospital MortalityHumansIntra-Aortic Balloon PumpingMaleMatched-Pair AnalysisMiddle AgedMyocardial InfarctionPercutaneous Coronary InterventionPropensity ScoreRegistriesRetrospective StudiesShock, CardiogenicST Elevation Myocardial InfarctionConceptsMicroaxial left ventricular assist deviceIntra-aortic balloon pumpLeft ventricular assist deviceAcute myocardial infarctionPercutaneous coronary interventionNational Cardiovascular Data RegistryCardiogenic shockHemodynamic supportMyocardial infarctionRegistry-based retrospective cohort studyCardiology-National Cardiovascular Data RegistryChest Pain-MI RegistryST-elevation myocardial infarctionMechanical circulatory support devicesGreater hemodynamic supportHospital major bleedingRetrospective cohort studyPropensity-matched pairsCirculatory support devicesVentricular assist deviceClinical laboratory dataHospital mortalityMajor bleedingHospital deathCohort study
2018
Enhancing the prediction of acute kidney injury risk after percutaneous coronary intervention using machine learning techniques: A retrospective cohort study
Huang C, Murugiah K, Mahajan S, Li SX, Dhruva SS, Haimovich JS, Wang Y, Schulz WL, Testani JM, Wilson FP, Mena CI, Masoudi FA, Rumsfeld JS, Spertus JA, Mortazavi BJ, Krumholz HM. Enhancing the prediction of acute kidney injury risk after percutaneous coronary intervention using machine learning techniques: A retrospective cohort study. PLOS Medicine 2018, 15: e1002703. PMID: 30481186, PMCID: PMC6258473, DOI: 10.1371/journal.pmed.1002703.Peer-Reviewed Original ResearchMeSH KeywordsAcute Kidney InjuryAgedClinical Decision-MakingData MiningDecision Support TechniquesFemaleHumansMachine LearningMaleMiddle AgedPercutaneous Coronary InterventionProtective FactorsRegistriesReproducibility of ResultsRetrospective StudiesRisk AssessmentRisk FactorsTime FactorsTreatment OutcomeConceptsPercutaneous coronary interventionNational Cardiovascular Data RegistryRisk prediction modelAKI eventsAKI riskCoronary interventionAKI modelMean ageCardiology-National Cardiovascular Data RegistryAcute kidney injury riskAKI risk predictionRetrospective cohort studyIdentification of patientsCandidate variablesAvailable candidate variablesCohort studyPCI proceduresPoint of careBrier scoreAmerican CollegeData registryPatientsCalibration slopeInjury riskSame cohortQuantifying the utilization of medical devices necessary to detect postmarket safety differences: A case study of implantable cardioverter defibrillators
Bates J, Parzynski CS, Dhruva SS, Coppi A, Kuntz R, Li S, Marinac‐Dabic D, Masoudi FA, Shaw RE, Warner F, Krumholz HM, Ross JS. Quantifying the utilization of medical devices necessary to detect postmarket safety differences: A case study of implantable cardioverter defibrillators. Pharmacoepidemiology And Drug Safety 2018, 27: 848-856. PMID: 29896873, PMCID: PMC6436550, DOI: 10.1002/pds.4565.Peer-Reviewed Original ResearchConceptsAdverse event ratesSafety differencesEvent ratesMedical device utilizationICD utilizationRate ratioNational Cardiovascular Data RegistryICD modelsImplantable cardioverter defibrillatorEvent rate ratioMost patientsCardioverter defibrillatorProportion of individualsAmerican CollegeData registryRoutine surveillanceSample size estimatesAverage event rateDevice utilizationSignificance levelDifferencesPatientsRegistryDefibrillatorICD
2016
Long-Term Risk for Device-Related Complications and Reoperations After Implantable Cardioverter-Defibrillator Implantation: An Observational Cohort Study.
Ranasinghe I, Parzynski CS, Freeman JV, Dreyer RP, Ross JS, Akar JG, Krumholz HM, Curtis JP. Long-Term Risk for Device-Related Complications and Reoperations After Implantable Cardioverter-Defibrillator Implantation: An Observational Cohort Study. Annals Of Internal Medicine 2016, 165: 20-29. PMID: 27135392, DOI: 10.7326/m15-2732.Peer-Reviewed Original ResearchICD-related complicationsNational Cardiovascular Data RegistryObservational cohort studyDevice-related complicationsICD implantationLong-term riskCohort studyMedicare feeNational Cardiovascular Data Registry ICD RegistryImplantable cardioverter defibrillator implantationImplantable cardioverter-defibrillator placementCardioverter-defibrillator implantationService claims dataCRT-D devicesSingle-chamber devicesCumulative incidenceNonfatal outcomesICD RegistryService patientsBlack raceFemale sexReoperationAmerican CollegeClaims dataComplications
2008
Time-to-Reperfusion in Patients Undergoing Interhospital Transfer for Primary Percutaneous Coronary Intervention in the U.S An Analysis of 2005 and 2006 Data From the National Cardiovascular Data Registry
Chakrabarti A, Krumholz HM, Wang Y, Rumsfeld JS, Nallamothu BK, Registry C. Time-to-Reperfusion in Patients Undergoing Interhospital Transfer for Primary Percutaneous Coronary Intervention in the U.S An Analysis of 2005 and 2006 Data From the National Cardiovascular Data Registry. Journal Of The American College Of Cardiology 2008, 51: 2442-2443. PMID: 18565404, PMCID: PMC3733497, DOI: 10.1016/j.jacc.2008.02.071.Peer-Reviewed Original ResearchConceptsPrimary percutaneous coronary interventionNational Cardiovascular Data RegistryPercutaneous coronary interventionCoronary interventionInterhospital transferData registryReperfusionPatientsRegistryAn Analysis
2007
Comparing Hospital Performance in Door-to-Balloon Time Between the Hospital Quality Alliance and the National Cardiovascular Data Registry
Nallamothu BK, Wang Y, Bradley EH, Ho KK, Curtis JP, Rumsfeld JS, Masoudi FA, Krumholz HM. Comparing Hospital Performance in Door-to-Balloon Time Between the Hospital Quality Alliance and the National Cardiovascular Data Registry. Journal Of The American College Of Cardiology 2007, 50: 1517-1519. PMID: 17919575, DOI: 10.1016/j.jacc.2007.07.010.Peer-Reviewed Original ResearchConceptsNational Cardiovascular Data RegistryHospital Quality AllianceBalloon timeData registryQuality AllianceHospital performanceRegistry