2015
Bioabsorbable polymer‐coated sirolimus‐eluting stent implantation preserves coronary vasomotion: A DESSOLVE II trial sub‐study
Rusinaru D, Vrolix M, Verheye S, Chowdhary S, Schoors D, Di Mario C, Desmet W, Donohoe DJ, Ormiston JA, Knape C, Bezerra H, Lansky A, Wijns W, Investigators O. Bioabsorbable polymer‐coated sirolimus‐eluting stent implantation preserves coronary vasomotion: A DESSOLVE II trial sub‐study. Catheterization And Cardiovascular Interventions 2015, 86: 1141-1150. PMID: 25044635, DOI: 10.1002/ccd.25610.Peer-Reviewed Original ResearchMeSH KeywordsAbsorbable ImplantsAgedCardiac Pacing, ArtificialCardiovascular AgentsCoronary AngiographyCoronary Artery DiseaseCoronary VesselsDrug-Eluting StentsEuropeFemaleHistorically Controlled StudyHumansMaleMiddle AgedNew ZealandPercutaneous Coronary InterventionPolymersProspective StudiesSingle-Blind MethodSirolimusTime FactorsTreatment OutcomeVasoconstrictionVasodilationConceptsZotarolimus-eluting stentsDrug-eluting stentsCoronary vasomotionII trialVasomotor dysfunctionFirst-generation drug-eluting stentsEndeavor zotarolimus-eluting stentsGeneration drug-eluting stentsCoronary vasomotor dysfunctionSirolimus-eluting stentsQuantitative coronary angiographyVessel diameterMaximal pacingCoronary angiographyZES groupCoronary arteryVasomotor responsesHistorical groupStent edgeNormal vasomotionPatientsPercent changeReference segmentsVasomotionSES group
2009
Intravascular Ultrasound Assessment of the Incidence and Predictors of Edge Dissections After Drug-Eluting Stent Implantation
Liu X, Tsujita K, Maehara A, Mintz GS, Weisz G, Dangas GD, Lansky AJ, Kreps EM, Rabbani LE, Collins M, Stone GW, Moses JW, Mehran R, Leon MB. Intravascular Ultrasound Assessment of the Incidence and Predictors of Edge Dissections After Drug-Eluting Stent Implantation. JACC Cardiovascular Interventions 2009, 2: 997-1004. PMID: 19850262, DOI: 10.1016/j.jcin.2009.07.012.Peer-Reviewed Original ResearchConceptsStent edge dissectionEdge dissectionDES implantationPlaque eccentricityIntravascular ultrasoundIntramural hematomaPlaque burdenStent implantationStent edgeDrug-Eluting Stent ImplantationDistal stent edgeStent restenosis lesionsBare-metal stentingIntravascular ultrasound assessmentResidual plaque areaCoronary dissectionRestenosis lesionsAngiographic findingsIndependent predictorsHematoma groupResidual plaqueUltrasound assessmentDissection groupPlaque areaNondissection group
2002
Results of the Jostent coronary stent graft implantation in various clinical settings: Procedural and follow‐up results
Gercken U, Lansky AJ, Buellesfeld L, Desai K, Badereldin M, Mueller R, Selbach G, Leon MB, Grube E. Results of the Jostent coronary stent graft implantation in various clinical settings: Procedural and follow‐up results. Catheterization And Cardiovascular Interventions 2002, 56: 353-360. PMID: 12112888, DOI: 10.1002/ccd.10223.Peer-Reviewed Original ResearchConceptsCoronary stent graftSaphenous vein graftsOverall restenosis rateStent graftRestenosis rateCoronary perforationStent restenosisAntiplatelet therapyVein graftsStent implantationComplex lesionsStent edgeStainless steel stentsHigh primary success ratePrimary angiographic success rateAngiographic success ratePrimary success ratePTFE layerIntravascular ultrasound guidanceLate lumen lossStent-graft implantationVein graft lesionsQ-wave MIComplex lesion subsetsTransient ventricular fibrillation