2024
Noise-aware dynamic image denoising and positron range correction for Rubidium-82 cardiac PET imaging via self-supervision
Xie H, Guo L, Velo A, Liu Z, Liu Q, Guo X, Zhou B, Chen X, Tsai Y, Miao T, Xia M, Liu Y, Armstrong I, Wang G, Carson R, Sinusas A, Liu C. Noise-aware dynamic image denoising and positron range correction for Rubidium-82 cardiac PET imaging via self-supervision. Medical Image Analysis 2024, 100: 103391. PMID: 39579623, DOI: 10.1016/j.media.2024.103391.Peer-Reviewed Original ResearchImage denoisingPositron range correctionDynamic framesSelf-supervised methodsSuperior visual qualityLow signal-to-noise ratioCardiac PET imagingDenoising methodSignal-to-noise ratioSelf-supervisionVisual qualityHigh-energy positronsRange correctionsDenoisingNoise levelImage spatial resolutionImage qualityDefect contrastPET imagingImage quantificationRadioactive isotopesPatient scansQuantitative accuracyImagesFrameDose-aware Diffusion Model for 3D Low-count Cardiac SPECT Image Denoising with Projection-domain Consistency
Xie H, Gan W, Chen X, Zhou B, Liu Q, Xia M, Guo X, Liu Y, An H, Kamilov U, Wang G, Sinusas A, Liu C. Dose-aware Diffusion Model for 3D Low-count Cardiac SPECT Image Denoising with Projection-domain Consistency. 2024, 00: 1-1. DOI: 10.1109/nss/mic/rtsd57108.2024.10655170.Peer-Reviewed Original ResearchImage denoisingImage denoising performanceDeep learning techniquesNoise-levelDenoising performanceDenoising resultsNeural networkLearning techniquesSPECT imagesLow count levelsSPECT scansDenoisingSampling stepIterative reconstructionNoise amplitudeImagesInjected dosePatient studiesDiffusion modelRadiation exposureCardiology studiesSPECTNetworkStochastic natureMLEMDuDoCFNet: Dual-Domain Coarse-to-Fine Progressive Network for Simultaneous Denoising, Limited-View Reconstruction, and Attenuation Correction of Cardiac SPECT
Chen X, Zhou B, Guo X, Xie H, Liu Q, Duncan J, Sinusas A, Liu C. DuDoCFNet: Dual-Domain Coarse-to-Fine Progressive Network for Simultaneous Denoising, Limited-View Reconstruction, and Attenuation Correction of Cardiac SPECT. IEEE Transactions On Medical Imaging 2024, 43: 3110-3125. PMID: 38578853, PMCID: PMC11539864, DOI: 10.1109/tmi.2024.3385650.Peer-Reviewed Original ResearchMulti-task learning methodCross-domainLimited-viewLearning methodsCoarse-to-fine estimationProgressive networkDual domainCross-modal feature fusionDual-domain networkProgressive learning strategyCross-modal informationSimultaneous denoisingFeature fusionSingle-photon emission computed tomographyImage domainCardiac single-photon emission computed tomographyReconstruction accuracyDenoisingHardware expenseFusion mechanismAccelerated scansImage noiseM-mapSuperior accuracyNetwork
2023
Dual-Domain Iterative Network with Adaptive Data Consistency for Joint Denoising and Few-Angle Reconstruction of Low-Dose Cardiac SPECT
Chen X, Zhou B, Xie H, Guo X, Liu Q, Sinusas A, Liu C. Dual-Domain Iterative Network with Adaptive Data Consistency for Joint Denoising and Few-Angle Reconstruction of Low-Dose Cardiac SPECT. Lecture Notes In Computer Science 2023, 14307: 49-59. DOI: 10.1007/978-3-031-44917-8_5.Peer-Reviewed Original ResearchIterative networkAuxiliary modulesJoint denoisingLow reconstruction accuracySource codeData consistencyNetwork performanceAblation studiesReconstruction accuracyCardiac SPECTConsistency moduleHardware expensePrediction accuracyAngle reconstructionNetworkDenoisingImage noiseAngle projectionsModuleADC moduleAccuracyReconstructionImagesMPI dataCode