2018
Three-Dimensional Printing for Construction of Tissue-Equivalent Anthropomorphic Phantoms and Determination of Conceptus Dose.
Hoerner MR, Maynard MR, Rajon DA, Bova FJ, Hintenlang DE. Three-Dimensional Printing for Construction of Tissue-Equivalent Anthropomorphic Phantoms and Determination of Conceptus Dose. American Journal Of Roentgenology 2018, 211: 1283-1290. PMID: 30354270, DOI: 10.2214/ajr.17.19489.Peer-Reviewed Original ResearchConceptsPrinting technologyTissue-equivalent materialsFabrication of phantomsThree-dimensional printingFiller powderBone materialDiagnostic energy X-raysUrethane polymersPhantom materialConstruction timeAttenuation propertiesPhantom constructionComputational modelSpatial accuracySpatial resolutionMaterialsEnergy X-raysBone tissueComplex modelingScan rangeDosimetry purposesDensityDosimetry applicationsPhantomPhantom assembly
2011
Monitoring proton radiation therapy with in-room PET imaging
Zhu X, España S, Daartz J, Liebsch N, Ouyang J, Paganetti H, Bortfeld T, Fakhri G. Monitoring proton radiation therapy with in-room PET imaging. Physics In Medicine And Biology 2011, 56: 4041-4057. PMID: 21677366, PMCID: PMC3141290, DOI: 10.1088/0031-9155/56/13/019.Peer-Reviewed Original ResearchConceptsIn-room positron emission tomographyIn-roomProton therapy treatment roomPositron emission tomography systemProton range verificationSoft tissue-equivalent materialMonte Carlo predictionsTissue-equivalent materialsPositron emission tomography acquisition timesProton radiation therapyPositron emission tomographyBiological washoutRange verificationProton therapyList-modeActivity distribution patternsPhantom studyTreatment roomPET acquisitionSoft tissue regionsIn vivo verificationDeep-siteOff-line modalityPositron emission tomography dataAdenoid cystic carcinomaTH‐C‐BRB‐04: Reliability of Proton‐Nuclear Interaction Cross Section Data to Predict Proton‐Induced PET Images in Proton Therapy
España S, Zhu X, Daartz J, Fakhri G, Bortfeld T, Paganetti H. TH‐C‐BRB‐04: Reliability of Proton‐Nuclear Interaction Cross Section Data to Predict Proton‐Induced PET Images in Proton Therapy. Medical Physics 2011, 38: 3853-3854. DOI: 10.1118/1.3613509.Peer-Reviewed Original ResearchCross section valuesCross section dataProton beamSection valuesIn vivo range verification methodsReaction channelsSection dataMonte Carlo codeTissue-equivalent materialsHigh-resolution PET scannerMeasured PET imagesRange verificationCross sectional DataPET imagingProton therapyIsotope productionPET scannerPET isotopesActivity distributionTheoretical valuesPhantomProtonBeamCrossField irradiation
2009
Construction of anthropomorphic phantoms for use in dosimetry studies
Winslow J, Hyer D, Fisher R, Tien C, Hintenlang D. Construction of anthropomorphic phantoms for use in dosimetry studies. Journal Of Applied Clinical Medical Physics 2009, 10: 195-204. PMID: 19692982, PMCID: PMC5720556, DOI: 10.1120/jacmp.v10i3.2986.Peer-Reviewed Original Research
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply