2024
Validation of a Simplified Tissue-to-Reference Ratio Measurement Using SUVR to Assess Synaptic Density Alterations in Alzheimer Disease with [11C]UCB-J PET
Young J, O’Dell R, Naganawa M, Toyonaga T, Chen M, Nabulsi N, Huang Y, Cooper E, Miller A, Lam J, Bates K, Ruan A, Nelsen K, Salardini E, Carson R, van Dyck C, Mecca A. Validation of a Simplified Tissue-to-Reference Ratio Measurement Using SUVR to Assess Synaptic Density Alterations in Alzheimer Disease with [11C]UCB-J PET. Journal Of Nuclear Medicine 2024, 65: jnumed.124.267419. PMID: 39299782, PMCID: PMC11533916, DOI: 10.2967/jnumed.124.267419.Peer-Reviewed Original ResearchDistribution volume ratioSUV ratioSynaptic densityEffect sizeAlzheimer's diseaseLongitudinal study of Alzheimer's diseaseMethods:</b> ParticipantsLongitudinal studyMeasure synaptic densityAD participantsStudy of Alzheimer's diseaseNormal cognitionReference regionOlder adultsMulticenterDensity alterationsNoninvasive quantification of [18F]SynVesT-1 binding using simplified reference tissue model 2
Naganawa M, Gallezot J, Li S, Nabulsi N, Henry S, Cai Z, Matuskey D, Huang Y, Carson R. Noninvasive quantification of [18F]SynVesT-1 binding using simplified reference tissue model 2. European Journal Of Nuclear Medicine And Molecular Imaging 2024, 1-9. PMID: 39155309, DOI: 10.1007/s00259-024-06885-6.Peer-Reviewed Original ResearchPositron emission tomographyCentrum semiovaleReference regionPositron emission tomography scanTest-retest variabilityTest-retest reproducibilitySynaptic vesicle glycoprotein 2AOne-tissue compartmentArterial blood samplesRetest scansGold standardBrain uptakeEmission tomographyBlood samplesCerebellumNoninvasive quantificationSRTM2ConclusionOur findingsPopulation averageHealthy participantsMetabolite analysisScan timeBPNDSemiovale
2020
First-in-Human Evaluation of 18F-SynVesT-1, a Radioligand for PET Imaging of Synaptic Vesicle Glycoprotein 2A
Naganawa M, Li S, Nabulsi N, Henry S, Zheng MQ, Pracitto R, Cai Z, Gao H, Kapinos M, Labaree D, Matuskey D, Huang Y, Carson RE. First-in-Human Evaluation of 18F-SynVesT-1, a Radioligand for PET Imaging of Synaptic Vesicle Glycoprotein 2A. Journal Of Nuclear Medicine 2020, 62: 561-567. PMID: 32859701, PMCID: PMC8049363, DOI: 10.2967/jnumed.120.249144.Peer-Reviewed Original ResearchConceptsC-UCBSynaptic densityRegional time-activity curvesTime-activity curvesDistribution volumeMetabolite-corrected arterial input functionPET imagingMultilinear analysis 1Synaptic vesicle glycoprotein 2AAntiepileptic drug levetiracetamTotal distribution volumeNondisplaceable distribution volumeCentrum semiovaleBlocking doseHealthy volunteersHuman studiesDrug levetiracetamLassen plotNeuropsychiatric disordersPET radioligandArterial input functionNonhuman primatesLevetiracetamReference regionRadioligandFirst-in-Human Assessment of 11C-LSN3172176, an M1 Muscarinic Acetylcholine Receptor PET Radiotracer
Naganawa M, Nabulsi N, Henry S, Matuskey D, Lin SF, Slieker L, Schwarz AJ, Kant N, Jesudason C, Ruley K, Navarro A, Gao H, Ropchan J, Labaree D, Carson RE, Huang Y. First-in-Human Assessment of 11C-LSN3172176, an M1 Muscarinic Acetylcholine Receptor PET Radiotracer. Journal Of Nuclear Medicine 2020, 62: 553-560. PMID: 32859711, PMCID: PMC8049371, DOI: 10.2967/jnumed.120.246967.Peer-Reviewed Original ResearchConceptsSimplified reference tissue modelM1 receptorsHealthy subjectsMuscarinic acetylcholine receptor subtype M1Distribution volumePET radiotracersAbsolute test-retest variabilityExcellent test-retest reproducibilityReference tissue model 2Total distribution volumeSuitable reference regionTest-retest reproducibilityTest-retest variabilityReference regionTest-retest protocolNondisplaceable distribution volumeReference tissue modelTest-retest studySubtypes M1Preclinical studiesRegional time-activity curvesAcetylcholine concentrationHuman studiesReceptor occupancyTime-activity curves
2019
Assessment of a white matter reference region for 11C-UCB-J PET quantification
Rossano S, Toyonaga T, Finnema SJ, Naganawa M, Lu Y, Nabulsi N, Ropchan J, De Bruyn S, Otoul C, Stockis A, Nicolas JM, Martin P, Mercier J, Huang Y, Maguire RP, Carson RE. Assessment of a white matter reference region for 11C-UCB-J PET quantification. Cerebrovascular And Brain Metabolism Reviews 2019, 40: 1890-1901. PMID: 31570041, PMCID: PMC7446568, DOI: 10.1177/0271678x19879230.Peer-Reviewed Original Research
2015
Test–Retest Reproducibility of Binding Parameters in Humans with 11C-LY2795050, an Antagonist PET Radiotracer for the κ Opioid Receptor
Naganawa M, Zheng MQ, Henry S, Nabulsi N, Lin SF, Ropchan J, Labaree D, Najafzadeh S, Kapinos M, Tauscher J, Neumeister A, Carson RE, Huang Y. Test–Retest Reproducibility of Binding Parameters in Humans with 11C-LY2795050, an Antagonist PET Radiotracer for the κ Opioid Receptor. Journal Of Nuclear Medicine 2015, 56: 243-248. PMID: 25593119, PMCID: PMC4322754, DOI: 10.2967/jnumed.114.147975.Peer-Reviewed Original ResearchConceptsTest-retest variabilityOpioid receptorsOutcome measuresAbsolute test-retest variabilityMultilinear analysis 1Healthy human subjectsSuitable reference regionTest-retest reproducibilityIntraclass correlation coefficientAntagonist radiotracersHealthy subjectsLY2795050PET scansBrain regionsDistribution volumePET radioligandTest-retest performancePET studiesArterial input functionPET radiotracersHuman subjectsReference regionReceptorsVT valuesKOR
2014
Test-retest variability of adenosine A2A binding in the human brain with 11C-TMSX and PET
Naganawa M, Mishina M, Sakata M, Oda K, Hiura M, Ishii K, Ishiwata K. Test-retest variability of adenosine A2A binding in the human brain with 11C-TMSX and PET. EJNMMI Research 2014, 4: 76. PMID: 25621197, PMCID: PMC4293456, DOI: 10.1186/s13550-014-0076-9.Peer-Reviewed Original ResearchTest-retest variabilityCerebral cortexCentrum semiovaleMethodsFive healthy volunteersNon-displaceable uptakeLow test-retest variabilityReference regionArterial blood samplingTest-retest reproducibilityCandidate reference regionsHuman brainTest-retest studyHealthy volunteersAdenosine A2ABlood samplingDistribution volumeInvasive methodNoninvasive methodReceptor quantificationBPNDCortexBrainPresent studySimilar levelsPET
2007
Distribution volume as an alternative to the binding potential for sigma1 receptor imaging
Kimura Y, Naganawa M, Sakata M, Ishikawa M, Mishina M, Oda K, Ishii K, Ishiwata K. Distribution volume as an alternative to the binding potential for sigma1 receptor imaging. Annals Of Nuclear Medicine 2007, 21: 533-535. PMID: 18030587, DOI: 10.1007/s12149-007-0063-6.Peer-Reviewed Original ResearchMeSH KeywordsAdultAgedAnatomy, RegionalBrainBrain MappingCarbon RadioisotopesData Interpretation, StatisticalFemaleHumansImage Processing, Computer-AssistedMaleMiddle AgedNonlinear DynamicsPiperazinesPositron-Emission TomographyRadioligand AssayRadiopharmaceuticalsReceptors, sigmaReference StandardsConceptsPositron emission tomographyDistribution volumeTotal distribution volumeReference regionReceptor densityClinical investigationReceptor imagingSigma1 receptorsEmission tomographyAppropriate reference regionReceptorsTarget receptorsPhysiological situationsNeuroreceptor mappingHigh affinityImagingDVTDiseaseRadioligandBrain
2005
Omission of serial arterial blood sampling in neuroreceptor imaging with independent component analysis
Naganawa M, Kimura Y, Nariai T, Ishii K, Oda K, Manabe Y, Chihara K, Ishiwata K. Omission of serial arterial blood sampling in neuroreceptor imaging with independent component analysis. NeuroImage 2005, 26: 885-890. PMID: 15955498, DOI: 10.1016/j.neuroimage.2005.02.025.Peer-Reviewed Original ResearchConceptsArterial blood samplingBlood samplingCerebral glucose metabolismAdenosine A1 receptorsTotal distribution volumeSerial arterial blood samplingLogan plotPET imagesPlasma time-activity curveA1 receptorsHealthy subjectsGlucose metabolismTime-activity curvesDistribution volumeBrain diseasesDVTReference regionSubjectsParametric imagesDynamic PET images